Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - GAS PRESSURE TEST
Permit Number - T08CM00276
Inspection Description - PLUMBING - GAS PRESSURE TEST
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/22/2008 | PLUMBING - GAS PRESSURE TEST | Approved | IVRS - Inspection :* 1. PROVIDE DRAIN FOR BEER TAP DRAIN 2. DRAINS FROM SODA DISPENSER TO HAVE P-TRAP IF OVER 5' WITH PRIMER THEN GLUE FOR PVC SCH40 PER 2006 UPC INSTALLATION STANDARDS WITH APPROVED SUPPORTS. 3. PROVIDE 6" MINIMUM CRITICAL LEVEL FOR URINAL FLUSH VALVE 4. SHOW ACCESS FOR WATER HAMMER ARRESTOR 5. SUPPORT ICE MACHINE DRAIN PIPING |
|
| 05/09/2008 | PLUMBING - GAS PRESSURE TEST | Partial Approval | IVRS - Inspection :* FROM METER LOCATION THRU ANSUL VALVE JUMPER TO CAPS AT ALL APPLIANCES TEST OK 1. PROVIDE SUPPORT ON OVERHEAD TO EAST ROOFTOP UNIT 2. TEST REQUIRED THRU ANSUL VALVE AFTER INSTALL OF IT AND APPLIANCE SHUT OFF VALVES |