Permit: T08CM00276

Parcel: 13331159W


Addresses:

8838 E BROADWAY BL


Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Permit Number - T08CM00276

Inspection Description - PLUMBING - GAS PRESSURE TEST

Inspection Status - Approved

Date Description Inspector Results Comments
09/22/2008 PLUMBING - GAS PRESSURE TEST Approved IVRS - Inspection :*
1. PROVIDE DRAIN FOR BEER TAP DRAIN
2. DRAINS FROM SODA DISPENSER TO HAVE P-TRAP IF OVER 5' WITH PRIMER THEN GLUE FOR PVC SCH40 PER 2006 UPC
INSTALLATION STANDARDS WITH APPROVED SUPPORTS.
3. PROVIDE 6" MINIMUM CRITICAL LEVEL FOR URINAL
FLUSH VALVE
4. SHOW ACCESS FOR WATER HAMMER ARRESTOR
5. SUPPORT ICE MACHINE DRAIN PIPING
05/09/2008 PLUMBING - GAS PRESSURE TEST Partial Approval IVRS - Inspection :*
FROM METER LOCATION THRU ANSUL VALVE JUMPER TO CAPS AT ALL APPLIANCES TEST OK

1. PROVIDE SUPPORT ON OVERHEAD TO EAST ROOFTOP UNIT
2. TEST REQUIRED THRU ANSUL VALVE AFTER INSTALL OF IT AND APPLIANCE SHUT OFF VALVES