Permit: T07EL00698
Permit Details
Apply Date:
04/19/2007
Applicant:
EVAN PATTERSON
Description:
ELEC UPGRADES FOR MUSIC HALL AND TEMP CHILLERS ASSC W/T07CM00928
Contractors:
- LEE MECHANICAL CONTRACTING INC ,
Permit Reviews
Permit Number - T07EL00698
Permit Status: Final
Permit Description: ELEC UPGRADES FOR MUSIC HALL AND TEMP CHILLERS ASSC W/T07CM00928
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
04/19/2007 | ELECTRICAL | 04/19/2007 | COMPLETED |
04/19/2007 | 3RD PARTY REVIEW-REVISION/OTHER | 04/26/2007 | COMPLETED |
05/02/2007 | 3RD PARTY REVIEW-REVISION/OTHER | 05/02/2007 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T07EL00698
Permit Status: Final
Permit Description: ELEC UPGRADES FOR MUSIC HALL AND TEMP CHILLERS ASSC W/T07CM00928
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
04/19/2007 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T07EL00698
Permit Description: ELEC UPGRADES FOR MUSIC HALL AND TEMP CHILLERS ASSC W/T07CM00928
Total Completed Inspections - 7
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/14/2007 | ELECTRIC - UNDERGROUND | DSANTACR | Approved | IVRS - Inspection :* OK PRI-SEC CONDUITS AT LEO RICH CENTER |
06/07/2007 | ELECTRIC - TEMPORARY SERVICE | DSANTACR | Approved | IVRS - Inspection :* 1) DO NOT ENERGIZE FEEDER TO CHILLERS UNTILL CLARIFICATION FOR USE OF SE TRIPLEX, SEE NOTES LAST INSPECTION |
06/21/2007 | ELECTRIC - FINAL | DSANTACR | Approved | IVRS - Inspection :* 1. PROVIDE TEST RESULTS FOR GFI TEST PRIOR TO ENERGIZING FEEDERS 2. RECEIVED LETTER FROM ENGINEER FOR APPROVAL OF SE CABLING |
08/20/2007 | ELECTRIC - RECONNECT | DSANTACR | Approved | IVRS - Inspection :* 1) ORIGINAL INSPECTION NOTES: PROVIDE LETTER OF TORQUE FOR NEW 3000 AMP 208 GEAR 2) STILL NO RECORD OF GFI TEST PER NOTE #1 INSPECTION ON 6/2/107-1200 AMP 480V GEAR IS IN USE AT THIS TIME 3) CLEARANCE IS SUBJECT TO LETTER OF TORQUE FOR GEAR -------------------------------------------------------------------------------------------------1) CONTRACTOR REQUESTED RETURN PM 2) INSPECTION UNSCHEDULED $108.00 PAID CHECK #10293 3) 3000 AMP 208 MUSIC HALL: DO NOT ENERGIZE NEW LOADS PRIOR TO INSPECTORS APPROVAL 4) INSULATING BUSHINGS POPED OFF AT J-BOX FOR FEEDERS INTO EXISTING GEAR, NEED MORE THREADS, INSULATING BUSHINGS CANNOT SEAT PROPERLY. GROUND GUTTER AT EXISTING GEAR |
08/21/2007 | TEP CLEARANCE - AM | JWEATHER | Approved | INCR CLEARED FOR 265 S. CHURCH AVE PER D. SANTACRUZ |
08/22/2007 | ELECTRIC - INTERMEDIATE | DSANTACR | Approved | IVRS - Inspection :* RECEIVED LETTER FOR GFI MAIN TEST |
02/18/2009 | PERMIT FINALED | BFLORES | Approved |