Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
C of o
Type:
COMMERCIAL ALTERATION
Apply Date:
12/21/2007
Applicant:
RELIABLE PERMIT MANAGEMENT
Description:
TI:OFFICE
Contractors:
  • TRIUMPH BUILDERS SOUTHWEST LLC *C*

Permit Reviews

Permit Number - T07CM04809
Permit Status: C of o
Permit Description: TI:OFFICE
Start Date Submittal Complete Date Status  
01/09/2008 POST 3RD PARTY REVIEW 01/10/2008 COMPLETED Review Details
01/17/2008 3RD PARTY REVIEW-REVISION/OTHER 01/29/2008 COMPLETED Review Details
02/01/2008 3RD PARTY REVIEW-REVISION/OTHER 02/01/2008 COMPLETED Review Details
05/20/2008 3RD PARTY REVIEW-REVISION/OTHER 05/22/2008 COMPLETED Review Details
05/22/2008 POST 3RD PARTY REVIEW 05/29/2008 COMPLETED Review Details
08/25/2008 3RD PARTY REVIEW-REVISION/OTHER 08/28/2008 COMPLETED Review Details
12/21/2007 PLANS OK TO SUBMIT - 3RD PARTY 12/21/2007 COMPLETED Review Details
12/21/2007 3RD PARTY REVIEW-COMMERCIAL TI 01/09/2008 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T07CM04809
Permit Status: C of o
Permit Description: TI:OFFICE
Total Outstanding Activity Conditions - 1
Date Name
12/21/2007 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: C of o
Permit Number: T07CM04809
Permit Description: TI:OFFICE
Total Completed Inspections - 34
Date Description Inspector Results Comments
02/15/2008 SHEET ROCK NAILING JBURGE Approved IVRS - Inspection :*
OK TO TAPE - #125, 116, 117, 118
02/19/2008 REINFORCED MASONRY PRE-GROUT JBURGE Approved WEST LEADING SCREEN WALL @ 40" TO 84"
MASONRY SCREEN WALL @ ELECTRIC SERVICE AREA
02/25/2008 TEP CLEARANCE - AM JWEATHER Approved TEC CLEARED PER R. JIROUDEK
03/13/2008 MECHANICAL - ABOVE CEILING JMILITEL Approved IVRS - Inspection :*
CHECKED FIRE DAMPERS IN DATA ROOM
CHECKED REMAINDER OF ABOVE CEILING
OK FOR CEILING TILES
03/13/2008 STUCCO MESH JBURGE Approved IVRS - Inspection :*
SOUTH ENTRY & WEST WALLS
OK TO STUCCO
03/19/2008 MECHANICAL - INTERMEDIATE JMILITEL Approved IVRS - Inspection :*
100 PSI TEST ON CHILLER PIPING OK TO INSULATE
OK FOR CEILING TILES IN LUNCH ROOM
03/25/2008 SIGN - FINAL JYBARRA Approved IVRS - Inspection :*
03/27/2008 RIGHT OF WAY - FINAL PWHIDDON Approved PER EMAIL
04/04/2008 FIRE - FINAL MBROWN Approved
07/11/2008 ELECTRIC - CABLE DROP RJIROUDE Approved
07/11/2008 ELECTRIC - FINAL RJIROUDE Approved IVRS - Inspection :*
07/11/2008 OUTDOOR LIGHTING FINAL RJIROUDE Approved IVRS - Inspection :*
07/11/2008 ELECTRIC - OUTDOOR LIGHTING RJIROUDE Approved IVRS - Inspection :*
07/11/2008 ELECTRIC - UNDERGROUND RJIROUDE Approved IVRS - Inspection :*
07/11/2008 ELECTRIC - INTERMEDIATE RJIROUDE Approved IVRS - Inspection :*
07/11/2008 ELECTRIC - ABOVE CEILING RJIROUDE Approved IVRS - Inspection :*
07/11/2008 PLUMBING - INTERMEDIATE RLEDONNE Approved IVRS - Inspection :*
07/11/2008 PLUMBING - ABOVE CEILING RLEDONNE Approved IVRS - Inspection :*
07/11/2008 PLUMBING - PRE SLAB RLEDONNE Approved IVRS - Inspection :*
07/11/2008 PLUMBING - ROUGH, SOIL RLEDONNE Approved IVRS - Inspection :*
07/15/2008 MECHANICAL - FINAL JMILITEL Approved IVRS - Inspection :*
07/15/2008 BUILDING ABOVE CEILING JBURGE Approved IVRS - Inspection :*
07/15/2008 FRAMING JBURGE Approved IVRS - Inspection :*
07/15/2008 EXT METAL CLIPS/EXT SHEATHING JBURGE Approved IVRS - Inspection :*
07/15/2008 BUILDING PRE-SLAB JBURGE Approved IVRS - Inspection :*
07/15/2008 EXCAVATION/LAYOUT REBAR & ZON JBURGE Approved IVRS - Inspection :*
07/15/2008 FIRE - ALARM FINAL LTHOMAS Approved
07/15/2008 FIRE SPKLR - FINAL LTHOMAS Approved
09/02/2008 PLUMBING - FINAL RLEDONNE Approved
09/02/2008 BUILDING - FINAL JBURGE Approved IVRS - Inspection :*
09/10/2008 ENGINEERING - FINAL JBRUCKME Approved OK TO EXTEND TEMP C OF O

1. PROVIDE THE REQUIRED # OF PARKING SPACES AS SHOWN ON THE PLAN
2. PROVIDE NEW EXTENDED CURBS AND CONCRETE WHEEL STOPS AS SHOWN ON THE PLAN
3. PROVIDE 8'6" PARKING SPACES RE-STRIPE ACCORDINGLY
4. PROVIDE NEW SIDEWALK SCUPPERS
5. PROVIDE POSITIVE DRAINAGE IN ROCK SWALE NEXT TO LOADING DOCK
09/10/2008 NPPO - FINAL ACONNOR Approved
09/10/2008 LANDSCAPE - FINAL ACONNOR Approved
02/12/2009 PERMIT FINALED JBRUCKME Approved

Documents

File Name Document Type  
C OF O_02-13-2009.TIF CERT OF OCC VIEW
TEMP C OF O_04-28-2008.TIF CERT OF OCC VIEW
TEMP C OF O_04-26-2008.TIF CERT OF OCC VIEW
TEMP C OF O_03-28-2008.TIF CERT OF OCC VIEW
SITE PLAN_01-28-2008.TIF CERT OF OCC VIEW
FLOOR PLAN_01-09-2008.TIF CERT OF OCC VIEW
T07CM04809_001.TIF CONSTRPLANS VIEW
T07CM04809_002.TIF CONSTRPLANS VIEW
T07CM04809_003.TIF CONSTRPLANS VIEW
T07CM04809_004.TIF CONSTRPLANS VIEW
T07CM04809_005.TIF CONSTRPLANS VIEW
T07CM04809_006.TIF CONSTRPLANS VIEW
T07CM04809_007.TIF CONSTRPLANS VIEW
T07CM04809_008.TIF CONSTRPLANS VIEW
T07CM04809_009.TIF CONSTRPLANS VIEW
T07CM04809_010.TIF CONSTRPLANS VIEW
T07CM04809_011.TIF CONSTRPLANS VIEW
T07CM04809_001.TIF CONSTRPLANS VIEW
T07CM04809_002.TIF CONSTRPLANS VIEW
T07CM04809_003.TIF CONSTRPLANS VIEW
T07CM04809_004.TIF CONSTRPLANS VIEW
T07CM04809_005.TIF CONSTRPLANS VIEW
T07CM04809_006.TIF CONSTRPLANS VIEW
T07CM04809_007.TIF CONSTRPLANS VIEW
T07CM04809_008.TIF CONSTRPLANS VIEW
T07CM04809_009.TIF CONSTRPLANS VIEW
T07CM04809_010.TIF CONSTRPLANS VIEW
T07CM04809_011.TIF CONSTRPLANS VIEW
T07CM04809_012.TIF CONSTRPLANS VIEW
T07CM04809_013.TIF CONSTRPLANS VIEW
T07CM04809_014.TIF CONSTRPLANS VIEW
T07CM04809_015.TIF CONSTRPLANS VIEW
T07CM04809_016.TIF CONSTRPLANS VIEW
T07CM04809_017.TIF CONSTRPLANS VIEW
T07CM04809_018.TIF CONSTRPLANS VIEW
T07CM04809_019.TIF CONSTRPLANS VIEW
T07CM04809_020.TIF CONSTRPLANS VIEW
T07CM04809_021.TIF CONSTRPLANS VIEW
T07CM04809_022.TIF CONSTRPLANS VIEW
T07CM04809_023.TIF CONSTRPLANS VIEW
T07CM04809_024.TIF CONSTRPLANS VIEW
T07CM04809_025.TIF CONSTRPLANS VIEW
T07CM04809_026.TIF CONSTRPLANS VIEW
T07CM04809_027.TIF CONSTRPLANS VIEW
T07CM04809_028.TIF CONSTRPLANS VIEW
T07CM04809_029.TIF CONSTRPLANS VIEW
T07CM04809_030.TIF CONSTRPLANS VIEW
T07CM04809_031.TIF CONSTRPLANS VIEW
T07CM04809_032.TIF CONSTRPLANS VIEW
T07CM04809_033.TIF CONSTRPLANS VIEW
T07CM04809_034.TIF CONSTRPLANS VIEW
T07CM04809_035.TIF CONSTRPLANS VIEW
001__P1.1.TIF CONSTRPLANS VIEW
002__P3.1.TIF CONSTRPLANS VIEW
003__1.TIF CONSTRPLANS VIEW
004__2.TIF CONSTRPLANS VIEW
SPECIALINSPRPTS.TIF DOCUMENTS VIEW
SPECIALINSPRPTS_03.TIF DOCUMENTS VIEW
None DOCUMENTS VIEW