Permit: T07CM04156
Permit Details
Apply Date:
10/23/2007
Applicant:
OLD TOWN BUILDERS INC
Description:
DUPLEX 16-89-56 T07-M0026 R1: REVISE DRIVEWAY 3/3/08
Contractors:
- OLD TOWN BUILDERS INC
Permit Reviews
Permit Number - T07CM04156
Permit Status: Final
Permit Description: DUPLEX 16-89-56 T07-M0026
R1: REVISE DRIVEWAY 3/3/08
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 03/03/2008 | REVISION - - 1ST | 03/03/2008 | COMPLETED |
| 10/23/2007 | RESIDENTIAL BLDG-MODEL PLAN/ENGINE/WALK THRU | 10/24/2007 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T07CM04156
Permit Status: Final
Permit Description: DUPLEX 16-89-56 T07-M0026
R1: REVISE DRIVEWAY 3/3/08
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 10/23/2007 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T07CM04156
Permit Description: DUPLEX 16-89-56 T07-M0026
R1: REVISE DRIVEWAY 3/3/08
Total Completed Inspections - 25
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/16/2007 | PLUMBING - ROUGH, SOIL | EDURAZO | Approved | IVRS - Inspection :* |
| 11/20/2007 | ELECTRIC - UFER | EDURAZO | Approved | IVRS - Inspection :* |
| 11/20/2007 | PLUMBING - PRE SLAB | EDURAZO | Approved | IVRS - Inspection :* |
| 11/20/2007 | BUILDING PRE-SLAB | EDURAZO | Approved | IVRS - Inspection :* |
| 11/20/2007 | EXCAVATION/LAYOUT REBAR & ZON | EDURAZO | Approved | IVRS - Inspection :* |
| 12/03/2007 | ROOF NAILING | EDURAZO | Approved | IVRS - Inspection :* |
| 12/20/2007 | FRAMING | EDURAZO | Approved | IVRS - Inspection :* 1) COMPLETE ALL TRADES AND STUCCO LATH 2) PROVIDE LEVEL/OR TRANSIT TO VERIFY POSITIVE FLOW AT SEWER FROM CLEANOUTS TO HCS CONNECTION |
| 12/20/2007 | PLUMBING - YARD WTR LINE/TEST | EDURAZO | Approved | IVRS - Inspection :* |
| 12/20/2007 | EXT METAL CLIPS/EXT SHEATHING | EDURAZO | Approved | IVRS - Inspection :* |
| 12/24/2007 | PLUMBING - SEWER HCS CONNECT | RFREIDIN | Approved | IVRS - Inspection : See detailed listing on site.| 999* 1) NEED 1/4" PER FT SLOPE ON 3" ABS, ALSO PROVIDE PLUMBING SITE PLAN FOR EJECTOR PUMP |
| 01/07/2008 | MECHANICAL - INTERMEDIATE | RFREIDIN | Approved | IVRS - Inspection :* |
| 01/07/2008 | ELECTRIC - INTERMEDIATE | RFREIDIN | Approved | IVRS - Inspection :* |
| 01/07/2008 | U VALUE FOR WINDOW | RFREIDIN | Approved | IVRS - Inspection :* |
| 01/07/2008 | STUCCO MESH | RFREIDIN | Approved | IVRS - Inspection :* |
| 01/10/2008 | PLUMBING - INTERMEDIATE | RFREIDIN | Approved | IVRS - Inspection :* |
| 01/10/2008 | ELECTRIC - CABLE DROP | RFREIDIN | Approved | IVRS - Inspection :* |
| 01/10/2008 | ELECTRIC - TEMPORARY SERVICE | RFREIDIN | Approved | IVRS - Inspection :* |
| 01/11/2008 | TEP CLEARANCE - AM | JWEATHER | Approved | ECO CLEARED FOR #1 & #2 PER R. FREIDINGER |
| 01/14/2008 | SHEET ROCK NAILING | CRUIZ | Approved | IVRS - Inspection :* |
| 02/29/2008 | MECHANICAL - FINAL | RCAMACHO | Approved | IVRS - Inspection :* |
| 02/29/2008 | PLUMBING - FINAL | RCAMACHO | Approved | IVRS - Inspection :* |
| 02/29/2008 | ELECTRIC - FINAL | RCAMACHO | Approved | IVRS - Inspection :* |
| 03/06/2008 | LANDSCAPE INSPECTION | ACONNOR | Approved | |
| 03/07/2008 | BUILDING - FINAL | CRUIZ | Approved | IVRS - Inspection :* |
| 03/10/2008 | PERMIT FINALED | JWEATHER | Approved |