Permit: T07CM04156

Parcel: 14020009D


Addresses:

5070 S PARK AV #01

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
01/10/2008 FRAMING Approved IVRS - Inspection :*
01/09/2008 FRAMING Not ready for Inspection IVRS - Inspection :*
NEED TO VERIFY FAN 1/8" PER FT 33' LENGTH
1) WEST UNIT: MISSING BANG PLATES, CONDENSATE, H20 SUPPLY
2) OVER NOTCHED STUD 3" VENT
3) LOOSE PLATE
4) END WALL H2.5 AT TOP CHORD
------------------------------------------------------------------------------------------------1) EAST UNIT: CLOSET FLANGE TO CLOSE TO TUB 15" MINIMUM
2) H2.5 AT END WALLS TO GO AT TOP CHORD
01/07/2008 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) INSTALL CONDUIT FOR ROOF PENETRATIONS 4 TOTAL-ROMEX 2 EACH SIDE
EAST UNIT:
1) NEED ALL DWV PIPING H20 TESTED
2) PROTECT ALL PIPING AND WIRING FROM SHEETROCK NAILING THRU-OUT
3) VENT CU. SHOWING THRU SHEATH, ANCHOR BOLT NEEDED AT BOTTOM PLATE BELOW VENT
4) H20 LINES NOT COMPLETED, TUB/SHOWER VALVES NOT INSTALLED
5) OVER NOTCHED STUD IN NORTH BATH
6) CONCRETE IN ALL TUB BLOCK OUTS
7) CLOSET FLANGE MIN. 15" SOUTH BATH
8) TWO OVERSPAN STUDS HALL BATH AND AT HALLWAY
9) INSTALL H2.5 AT 48" ON CENTER END WALLS
WEST UNIT:
1) SAME ITEMS FROM EAST UNIT BOTTOM SIMILAR
2) LOOSE PLATES THRU OUT
3) HCS: NEED JOINT SEWER AGREEMENT, PUT ALL 3 UNITS USING EJECTOR ON SITE PLAN, HAVE PIMA COUNTY OK SEWER PLAN, SEWER FROM HOUSE IS THAN EJECTOR INVERT. EJECTOR MUST BE VENTED, SEE ALL REQ. IN UPC
12/20/2007 FRAMING Not ready for Inspection IVRS - Inspection :*
1) COMPLETE ALL TRADES AND STUCCO LATH
2) PROVIDE LEVEL/OR TRANSIT TO VERIFY POSITIVE FLOW AT SEWER FROM CLEANOUTS TO HCS CONNECTION
12/05/2007 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NO PLANS FOUND
2) 1035 INSPECTION TO BE DONE AT INTERMEDIATES
3) COMPLY WITH PREVIOUS INSPECTION
12/03/2007 FRAMING Not ready for Inspection IVRS - Inspection :*