Inspection Status: Approved
Inspection History: PLUMBING - SEWER HCS CONNECT
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/01/2008 | PLUMBING - SEWER HCS CONNECT | Approved | IVRS - Inspection :* | |
| 01/18/2008 | PLUMBING - SEWER HCS CONNECT | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SUPPLY INFORMATION FROM MANUFACTURER FOR AN APPROVED SEALING METHOD, FOR LARGER HOLE CUT FOR IN VENT TO BE LOWERED |
|
| 01/14/2008 | PLUMBING - SEWER HCS CONNECT | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NOT READY 2) INSTALL CLEANOUT STACKS AT THIS TIME |
|
| 01/10/2008 | PLUMBING - SEWER HCS CONNECT | Not ready for Inspection | IVRS - Inspection :* 1) 33' FROM CLEANOUT TO ? = 1/8" PER FT 4 1/8 TOTAL ? 2) 95 1/2 AT INVERT=2 3/4" FALL 3) 92 3/4 AT CLEANOUT |
|
| 01/09/2008 | PLUMBING - SEWER HCS CONNECT | Not ready for Inspection | IVRS - Inspection :* | |
| 01/07/2008 | PLUMBING - SEWER HCS CONNECT | Not ready for Inspection | IVRS - Inspection :* | |
| 12/24/2007 | PLUMBING - SEWER HCS CONNECT | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NEED 1/4" PER FT SLOPE ON 3" ABS, ALSO PROVIDE PLUMBING SITE PLAN FOR EJECTOR PUMP |
|
| 12/21/2007 | PLUMBING - SEWER HCS CONNECT | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) CHECK ALL SEWER LINE FOR POSITIVE FLOW 2) 1/8" MIN PER FOOT FOR 4" LINE 3) 1/4" MIN PER FOOT FOR 3" WASTE |
|
| 12/20/2007 | PLUMBING - SEWER HCS CONNECT | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
| 12/10/2007 | PLUMBING - SEWER HCS CONNECT | Not ready for Inspection | IVRS - Inspection :* CANCELED BY JOHN |
|
| 12/03/2007 | PLUMBING - SEWER HCS CONNECT | Not ready for Inspection | IVRS - Inspection :* |