Permit: T07CM03748
Permit Details
Apply Date:
09/14/2007
Applicant:
RELIABLE PERMIT MANAGEMENT
Description:
TI: OFFICE
Architects:
- JOHNS, DAVID F
Contractors:
- CAYLOR CONSTRUCTION COMPANY , RO
Permit Reviews
Permit Number - T07CM03748
Permit Status: C of o
Permit Description: TI: OFFICE
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 09/14/2007 | PLANS OK TO SUBMIT - 3RD PARTY | 09/18/2007 | COMPLETED |
| 09/18/2007 | 3RD PARTY REVIEW-COMMERCIAL TI | 11/06/2007 | COMPLETED |
| 11/06/2007 | POST 3RD PARTY REVIEW | 11/06/2007 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T07CM03748
Permit Status: C of o
Permit Description: TI: OFFICE
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 09/14/2007 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T07CM03748
Permit Description: TI: OFFICE
Total Completed Inspections - 27
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/07/2007 | PLUMBING - PROGRESS | RMYERS | Approved | IVRS - Inspection :* |
| 11/07/2007 | PLUMBING - ABOVE CEILING | RMYERS | Approved | IVRS - Inspection :* |
| 11/07/2007 | PLUMBING - ROUGH, SOIL | RMYERS | Approved | IVRS - Inspection :* |
| 11/07/2007 | ELECTRIC - PROGRESS | CCLEMENS | Approved | IVRS - Inspection :* |
| 11/07/2007 | MECHANICAL - INTERMEDIATE | MRAMBER | Approved | IVRS - Inspection :* |
| 11/13/2007 | ELECTRIC - INTERMEDIATE | CCLEMENS | Approved | IVRS - Inspection :* 1) OK DRYWALL-NEED TO CHECK 1, 2 AND 4 |
| 11/13/2007 | FRAMING | AQUIROZ | Approved | IVRS - Inspection :* |
| 11/19/2007 | ELECTRIC - ABOVE CEILING | CCLEMENS | Approved | IVRS - Inspection :* 1) OK CEILING TILES |
| 11/19/2007 | BUILDING ABOVE CEILING | JBURGE | Approved | IVRS - Inspection :* OK TO SET TILES |
| 11/21/2007 | SHEET ROCK NAILING | AQUIROZ | Approved | IVRS - Inspection :* |
| 12/14/2007 | PLUMBING - INTERMEDIATE | RMYERS | Approved | IVRS - Inspection :* 1. WATER CLOSETS SET WITHOUT FLANGE INSPECTION 2. CONTINUED NOT READY WILL RESULT IN A REINSPECTION FEE REINSPECTED CORRECT ADDRESS - FLANGES OK |
| 12/17/2007 | ELECTRIC - FINAL | CCLEMENS | Approved | IVRS - Inspection : See detailed listing on site.| 999* 1. POWER POWER, CALL CORRECT INSPECTION CODE IN (02062) 2. NEED TO POST POWER BOND 3. SINGLE LINE DIAGRAM NEEDS TO BE REVISED AND RESUBMITTED THROUGH PLAN REVIEW 4. EQUIPMENT TO BE OPEN/ACCESSIBLE FOR INSPECTION *BOND POSTED TO SHELL ACTIVITY? |
| 12/17/2007 | PLUMBING - FINAL | RMYERS | Approved | IVRS - Inspection :* |
| 12/17/2007 | FIRE - FINAL | LTHOMAS | Approved | Visual inspection - OK to cover |
| 12/18/2007 | MECHANICAL - FINAL | MRAMBER | Approved | IVRS - Inspection : See detailed listing on site.| 999* PROVIDE BALANCE REPORT COMPLETE ALL MECHANICAL WORK ON ROOF |
| 12/18/2007 | MECHANICAL - ABOVE CEILING | MRAMBER | Approved | IVRS - Inspection :* |
| 12/28/2007 | ELECTRIC - TEMP POWER FOR TEST | CCLEMENS | Approved | IVRS - Inspection : STILL WAITING FOR REVISED SINGLE LINE DIAGRAM |
| 01/09/2008 | TEP CLEARANCE - AM | JWEATHER | Approved | TEC CLEARED FOR BOTH METERS PER C. CLEMENS |
| 01/23/2008 | RIGHT OF WAY - FINAL | MOTERO | Approved | PER EMAIL |
| 01/23/2008 | MECHANICAL - PROGRESS | MRAMBER | Approved | IVRS - Inspection :* |
| 01/23/2008 | FIRE SPKLR - FINAL | LTHOMAS | Approved | |
| 01/23/2008 | SIGN - FINAL | JYBARRA | Approved | |
| 01/23/2008 | NPPO - FINAL | ACONNOR | Approved | |
| 01/23/2008 | LANDSCAPE - FINAL | ACONNOR | Approved | |
| 02/04/2008 | BUILDING - FINAL | JBURGE | Approved | IVRS - Inspection :* |
| 02/05/2008 | BUILDING - PROGRESS | JBURGE | Approved | PER BU FINAL |
| 02/05/2008 | ENGINEERING - FINAL | MRUSSO | Approved |