Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
C of o
Type:
COMMERCIAL ALTERATION
Address NEW:
1200 N EL DORADO PL 03
Apply Date:
07/05/2007
Applicant:
ROBERT J TAYLOR
Description:
TI:DENTAL
Contractors:
  • JON JOHNSON DESIGN & CONSTRUCTION

Permit Reviews

Permit Number - T07CM02853
Permit Status: C of o
Permit Description: TI:DENTAL
Start Date Submittal Complete Date Status  
07/05/2007 COMMERCIAL TI 07/13/2007 COMPLETED Review Details
07/13/2007 RESUBMITTAL 08/23/2007 COMPLETED Review Details
09/06/2007 REVISION - - 1ST 09/13/2007 COMPLETED Review Details
10/11/2007 REVISION - - 2ND 10/22/2007 COMPLETED Review Details
10/22/2007 REVISION - - 2ND 12/07/2007 COMPLETED Review Details
12/07/2007 REVISION - - 3RD 12/07/2007 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T07CM02853
Permit Status: C of o
Permit Description: TI:DENTAL
Total Outstanding Activity Conditions - 1
Date Name
07/05/2007 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: C of o
Permit Number: T07CM02853
Permit Description: TI:DENTAL
Total Completed Inspections - 26
Date Description Inspector Results Comments
09/14/2007 PLUMBING - MEDICAL GAS/TEST BBENEDON Approved IVRS - Inspection :*
1 1/2 ABV VAC BELOW FLOOR W/5 PSI TEST
COMPRESSED AIR SYSTEM IS REQUIRED TO BE INSTALLED
PER NFPA 99 STANDARDS FOR MEDICAL GAS.
SCHEDULE A MEDICAL GAS PRE-CON MEETING W/INSTALLER
COT, GEN. CONTRACTOR, AND THIRD PARTY SPECIAL INSPECTOR AND (OWNER REP IF POSSIBLE)
09/14/2007 PLUMBING - ROUGH, SOIL BBENEDON Approved IVRS - Inspection :*
11/01/2007 MECHANICAL - INTERMEDIATE JMILITEL Approved IVRS - Inspection :*
11/01/2007 BUILDING ABOVE CEILING JBURGE Approved IVRS - Inspection :*
OK TO SET TILE
11/01/2007 FRAMING JBURGE Approved IVRS - Inspection :*
OK TO SHEETROCK THROUGHOUT
11/01/2007 BUILDING - PROGRESS JBURGE Approved IVRS - Inspection :*
11/02/2007 ELECTRIC - INTERMEDIATE RHOLLAND Approved IVRS - Inspection :*
OK WALLS & SOFFITS
11/07/2007 SHEET ROCK NAILING JBURGE Approved IVRS - Inspection :*
OK TO TAPE THROUGHOUT
12/04/2007 MECHANICAL - ABOVE CEILING JMILITEL Approved IVRS - Inspection :*
OK FOR CEILING TILES
12/04/2007 PLUMBING - INTERMEDIATE BBENEDON Approved IVRS - Inspection :*
CLOSET FLANGE OK IF LAMINATE FLOORING
IF TILE, CLOSET FLANGE SHALL REST ON FINISHED FLOOR
12/04/2007 PLUMBING - ABOVE CEILING BBENEDON Approved IVRS - Inspection :*
12/06/2007 ELECTRIC - ABOVE CEILING RHOLLAND Approved IVRS - Inspection :*
OK TO TILE
01/04/2008 TEP CLEARANCE - AM JWEATHER Approved TMPP CLEARED FOR #320 PER R. HOLLANDER
03/12/2008 ENGINEERING - FINAL JBRUCKME Approved
03/12/2008 SIGN - FINAL JYBARRA Approved IVRS - Inspection :*
03/12/2008 NPPO - FINAL ACONNOR Approved N/A
03/12/2008 LANDSCAPE - FINAL ACONNOR Approved N/A
03/12/2008 FIRE - FINAL LTHOMAS Approved
03/12/2008 RIGHT OF WAY - FINAL PWHIDDON Approved PER EMAIL
03/13/2008 MECHANICAL - FINAL JMILITEL Approved IVRS - Inspection :*
AIR BALANCE OK
03/13/2008 PLUMBING - MD GAS/PRECONST MTG BBENEDON Approved
03/13/2008 BUILDING - FINAL JBURGE Approved IVRS - Inspection :*
03/13/2008 PLUMBING - FINAL BBENEDON Approved IVRS - Inspection :*
03/13/2008 ELECTRIC - FINAL RHOLLAND Approved IVRS - Inspection :*
03/13/2008 ELECTRIC - TEMP POWER FOR TEST RHOLLAND Approved IVRS - Inspection :*
03/14/2008 PERMIT FINALED JWEATHER Approved

Documents

File Name Document Type  
C OF O_03-17-2008.TIF CERT OF OCC VIEW
T07CM02853-R3_001.TIF CONSTRPLANS VIEW
T07CM02853-R2_001.TIF CONSTRPLANS VIEW
T07CM02853-R_001.TIF CONSTRPLANS VIEW
T07CM02853_001.TIF CONSTRPLANS VIEW
T07CM02853_002.TIF CONSTRPLANS VIEW
T07CM02853_003.TIF CONSTRPLANS VIEW
T07CM02853_004.TIF CONSTRPLANS VIEW
None DOCUMENTS VIEW