Permit: T07CM02853

Parcel: 133146610

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
03/13/2008 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
12/04/2007 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
CLOSET FLANGE OK IF LAMINATE FLOORING
IF TILE, CLOSET FLANGE SHALL REST ON FINISHED FLOOR
11/15/2007 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
YARD WATER
INSTALLED PER RED LINES
OK TO BACKFILL IN ACCORDANCE W/UPC SEC 315.4
HAND SHADE PIPE BEFORE USING MECHANICAL EQUIPT. TO COMPLETE BACKFILL
11/14/2007 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
(YARD WATER INSPECTION)
PROVIDE AN ACCURATE SITE PLAN AND INSTALL PER PLAN
NO ADHESIVE TAPE ON PEX
PVC SPECIFIED
PROVIDE A TUCSON WATER PERMIT FOR NEW RP
REMOVE ROCKS FROM TRENCH
11/01/2007 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
DOMESTIC COPPER OK
COMPLETE INSTALLATION OF HW PIPE INSULATION
SUPPORT W.B OK TO COVER WALLS
SUPPORT ABV CEILING WATER PIPING OVER TOILET RM
SEPARATE FROM TOUCHING METAL
AIR PIPING NOT PER PLAN
WILL INSPECT CLOSET FLANGE AFTER F.F
10/05/2007 PLUMBING - INTERMEDIATE Cancelled IVRS - RI canceled
09/14/2007 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
OK TO COVER FLOOR
DWV TEST TO VENTS ABV CEILING OK