Permit: T07CM02699
Permit Details
Status:
C of o
Type:
COMMERCIAL ALTERATION
Address:
501 N PARK AV #120
Address NEW:
501 N PARK AV #120
Apply Date:
06/25/2007
Applicant:
METRO PERMIT EXPRESS, INC *C
Description:
TI: NICO'S TACOS HOOD W/COOKING EQUIPMENT
Architects:
- CATALANO, VINCENT VICTOR
Contractors:
- A UNITED RESTAURANT EQUIPMENT AN
Permit Reviews
Permit Number - T07CM02699
Permit Status: C of o
Permit Description: TI: NICO'S TACOS HOOD W/COOKING EQUIPMENT
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 06/25/2007 | PLANS OK TO SUBMIT - COMM | 06/25/2007 | COMPLETED |
| 06/25/2007 | 3RD PARTY REVIEW-COMMERCIAL TI | 07/18/2007 | COMPLETED |
| 07/16/2007 | POST 3RD PARTY REVIEW | 07/30/2007 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T07CM02699
Permit Status: C of o
Permit Description: TI: NICO'S TACOS HOOD W/COOKING EQUIPMENT
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 06/25/2007 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T07CM02699
Permit Description: TI: NICO'S TACOS HOOD W/COOKING EQUIPMENT
Total Completed Inspections - 26
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/16/2007 | PLUMBING - GAS PRESSURE TEST | RLEDONNE | Approved | IVRS - Inspection :* |
| 08/17/2007 | BUILDING ABOVE CEILING | JBURGE | Approved | IVRS - Inspection :* EXISTING SYSTEM - OK TO SET TILES |
| 08/17/2007 | FRAMING | JBURGE | Approved | IVRS - Inspection :* FRAMING @ HOOD ONLY -- ALL ELSE EXISTING |
| 08/28/2007 | PLUMBING - GAS PRESS TEST FNL | RRICH | Approved | IVRS - Inspection :* |
| 08/29/2007 | ROOF NAILING | JBURGE | Approved | |
| 08/29/2007 | SHEET ROCK NAILING | JBURGE | Approved | |
| 09/04/2007 | MECHANICAL - HOODS | JMILITEL | Approved | IVRS - Inspection :* |
| 09/04/2007 | MECHANICAL - ABOVE CEILING | JMILITEL | Approved | IVRS - Inspection :* |
| 09/04/2007 | MECHANICAL - INTERMEDIATE | JMILITEL | Approved | IVRS - Inspection :* OK FOR CEILING TILES LEFT GAS CARD |
| 09/04/2007 | PLUMBING - FINAL | RRICH | Approved | IVRS - Inspection :* GAS CARD WILL BE LEFT BY MECH. INSPECTOR |
| 09/04/2007 | PLUMBING - ABOVE CEILING | RRICH | Approved | IVRS - Inspection :* |
| 09/04/2007 | PLUMBING - INTERMEDIATE | RRICH | Approved | IVRS - Inspection :* |
| 09/12/2007 | FIRE - KITCHEN EXH HOOD FINAL | LLAKEY | Approved | |
| 09/14/2007 | ELECTRIC - ABOVE CEILING | RJIROUDE | Approved | IVRS - Inspection :* |
| 09/14/2007 | ELECTRIC - INTERMEDIATE | RJIROUDE | Approved | IVRS - Inspection :* |
| 09/17/2007 | RIGHT OF WAY - FINAL | MOTERO | Approved | PER EMAIL |
| 09/17/2007 | MECHANICAL - HOOD SYSTEMS | JMILITEL | Approved | IVRS - Inspection :* |
| 09/17/2007 | NPPO - FINAL | ACONNOR | Approved | N/A |
| 09/17/2007 | LANDSCAPE - FINAL | ACONNOR | Approved | N/A |
| 09/17/2007 | FIRE - FINAL | CSCHULTZ | Approved | |
| 09/18/2007 | ENGINEERING - FINAL | MRUSSO | Approved | C OF O FOR ENGINEERING APPROVED |
| 09/19/2007 | SIGN - FINAL | JYBARRA | Approved | |
| 09/28/2007 | ELECTRIC - FINAL | DSANTACR | Approved | |
| 09/28/2007 | HEALTH DEPT - FINAL 724-7908 | MRAMSEY | Approved | |
| 09/28/2007 | BUILDING - FINAL | JBURGE | Approved | IVRS - Inspection :* |
| 09/28/2007 | MECHANICAL - FINAL | MRAMBER | Approved | IVRS - Inspection :* |