Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Permit Details

Status:
C of o
Type:
COMMERCIAL ALTERATION
Address NEW:
5633 E SPEEDWAY BL
Apply Date:
06/13/2007
Applicant:
METRO PERMIT EXPRESS, INC *C
Description:
TI: DANCE STUDIO, Adding bathroom and demising walls
Architects:
  • MCCARTHY, BRIAN PATRICK
Contractors:
  • G AND J DEVELOPMENT INC ,

Permit Reviews

Permit Number - T07CM02470
Permit Status: C of o
Permit Description: TI: DANCE STUDIO, Adding bathroom and demising walls
Start Date Submittal Complete Date Status  
06/13/2007 COMMERCIAL TI 06/25/2007 COMPLETED Review Details
06/25/2007 COMMERCIAL TI 07/16/2007 COMPLETED Review Details
07/16/2007 COMMERCIAL TI 07/16/2007 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T07CM02470
Permit Status: C of o
Permit Description: TI: DANCE STUDIO, Adding bathroom and demising walls
Total Outstanding Activity Conditions - 1
Date Name
06/13/2007 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: C of o
Permit Number: T07CM02470
Permit Description: TI: DANCE STUDIO, Adding bathroom and demising walls
Total Completed Inspections - 23
Date Description Inspector Results Comments
07/19/2007 PLUMBING - ROUGH, SOIL RRICH Approved IVRS - Inspection :*
WASTE & VENT RESTROOM THRU ROOF TO BUILDING
EXTERIOR CONNECTION TO EXISTING WATER TEST OK
PIPE WRAPS OK
RESTROOM TRAP PRIMER/FLOOR DRAIN OK

1. BE SURE TO WRAP YOUR DRINKING FOUNTAIN
DRAIN RISER
07/19/2007 NPPO - FINAL ACONNOR Approved N/A
07/19/2007 LANDSCAPE - FINAL ACONNOR Approved N/A
07/19/2007 RIGHT OF WAY - FINAL SDAMRON Approved PER EMAIL
07/19/2007 SIGN - FINAL JSONKIN Approved IVRS - Inspection :*
07/20/2007 FRAMING JBURGE Approved IVRS - Inspection :*
OK TO SHEETROCK THROUGHOUT
* RECEIVED RFI CONCERNING FRAMING STUDS
07/23/2007 SHEET ROCK NAILING JBURGE Approved IVRS - Inspection :*
OK TO TAPE THROUGHOUT
07/25/2007 MECHANICAL - ABOVE CEILING JMILITEL Approved IVRS - Inspection :*
OK FOR CEILING TILES
BE SURE ALL CONDENSATE DRAINS ARE TERMINATED TO AN APPROVED LOCATION
07/25/2007 ELECTRIC - ABOVE CEILING RMAJUTA Approved IVRS - Inspection :*
07/25/2007 ELECTRIC - INTERMEDIATE RMAJUTA Approved IVRS - Inspection :*
07/26/2007 PLUMBING - INTERMEDIATE RMYERS Approved DOOR LOCKED
NO ACCESS
07/26/2007 PLUMBING - INTERMEDIATE RRICH Approved IVRS - Inspection :*
WASTE & VENT THRU ROOF & WATER PIPING APPROVED OK
08/01/2007 MECHANICAL - FINAL JMILITEL Approved IVRS - Inspection :*
NO CFU QUANTITIES LISTED FOR SUPPLY DIFFUSERS ON PLANS - OK FOR FINAL
08/01/2007 BUILDING ABOVE CEILING JBURGE Approved IVRS - Inspection :*
OK TO SET TILES
08/01/2007 PLUMBING - PROGRESS RRICH Approved IVRS - Inspection :*
CLOSET FLANGES & OVERHEAD ABOVE CEILING OK
08/01/2007 PLUMBING - PROGRESS IVR USER Approved IVRS - RI canceled
08/07/2007 ELECTRIC - FINAL RHOLLAND Approved IVRS - Inspection :*
08/07/2007 FIRE SPKLR - FINAL LTHOMAS Approved
08/07/2007 FIRE - FINAL LTHOMAS Approved
08/08/2007 ENGINEERING - FINAL JBRUCKME Approved
08/08/2007 BUILDING - FINAL JBURGE Approved
08/08/2007 BUILDING - PROGRESS JBURGE Approved
08/08/2007 PLUMBING - FINAL RRICH Approved IVRS - Inspection :*