Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
Permit Number - T07CM02470
Inspection Description - PLUMBING - ROUGH, SOIL
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/19/2007 | PLUMBING - ROUGH, SOIL | Approved | IVRS - Inspection :* WASTE & VENT RESTROOM THRU ROOF TO BUILDING EXTERIOR CONNECTION TO EXISTING WATER TEST OK PIPE WRAPS OK RESTROOM TRAP PRIMER/FLOOR DRAIN OK 1. BE SURE TO WRAP YOUR DRINKING FOUNTAIN DRAIN RISER |
|
| 07/18/2007 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* WATER TEST FROM EXISTING THRU ROOF FOR MOP SINK WASTE & VENT OK WATER TEST BUILDING INTERIOR ONLY THRU ROOF FOR NEW RESTROOM & SINK WASTE & VENT OK 1. SHALL PROVIDE VIEWING OF CONNECTION TO EXISTING BUILDING DRAIN THRU SEWER WITH DRY MATERIAL IN DITCH, FIRM BEDDING & SHADING 2. SHALL PROVIDE PIPE WRAPS WITH INSPECTION PRIOR TO CONCRETE POUR BACK. |