Apply Date:
04/04/2007
Applicant:
FENECK, JOHN
Description:
ADDITION & REMODEL:RETAIL
Architects:
- FENECK, JOHN
Contractors:
- BELFOR U S A GROUP INC
Permit Reviews
Permit Number - T07CM01391
Permit Status: Final
Permit Description: ADDITION & REMODEL:RETAIL
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 04/04/2007 | PLANS OK TO SUBMIT - 3RD PARTY | 05/04/2007 | COMPLETED |
| 04/04/2007 | PLANS OK TO SUBMIT - SITE | 05/04/2007 | COMPLETED |
| 04/11/2007 | 3RD PARTY REVIEW-COMMERCIAL TI | 04/26/2007 | COMPLETED |
| 04/26/2007 | POST 3RD PARTY REVIEW | 05/04/2007 | COMPLETED |
| 08/30/2007 | 3RD PARTY REVIEW-REVISION/OTHER | 09/04/2007 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T07CM01391
Permit Status: Final
Permit Description: ADDITION & REMODEL:RETAIL
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 04/04/2007 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T07CM01391
Permit Description: ADDITION & REMODEL:RETAIL
Total Completed Inspections - 30
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/11/2007 | EXCAVATION/LAYOUT REBAR & ZON | JBURGE | Approved | partial for south and west wall only |
| 05/11/2007 | BUILDING PRE-SLAB | JBURGE | Approved | IVRS - Inspection :* |
| 09/11/2007 | STEM WALL/RETAINING WALL | JBURGE | Approved | NORTH WALL @ 4' OK TO GROUT |
| 09/12/2007 | REINFORCED MASONRY PRE-GROUT | JBURGE | Approved | |
| 09/12/2007 | BUILDING - PROGRESS | JBURGE | Approved | IVRS - Inspection :* INFORMATION ONLY THIS OFFICE REQUIRES AN ENGINEERING REPORT VERIFYING THE EXISTENCE OF A FOOTING UNDER THE NORTH WALL. WORK IN THIS AREA MAY NOT PROCEED UNTIL THE REPORT IS RECEIVED BY THIS OFFICE. DO NOT GROUT NORTH WALL. *PLEASE RE-OPEN 01020 - CHANGE STATUS TO NOT READY |
| 12/03/2007 | FRAMING | JBURGE | Approved | IVRS - Inspection :* APPROXIMATELY 19 DAMAGED PERLINS REPLACED TWO STEEL COLUMNS REPAIRED/WELDED AT BASES FRAMING COMPLETED AS PER PLAN - OK TO SHEETROCK PENDING ELECTRIC & PLUMBING INTERMEDIATES * * REPORT REQUIRED AS PER 9/12/07 INSPECTION |
| 12/03/2007 | ROOF NAILING | JBURGE | Approved | IVRS - Inspection : See detailed listing on site.| 999* UNABLE TO ACCESS ROOF (NO LADDER) PRESENT |
| 12/21/2007 | PLUMBING - INTERMEDIATE | BBENEDON | Approved | IVRS - Inspection : See detailed listing on site.| 999* 1) READ PREVIOUS INSPECTION: NO TEST ON WATER PIPING 2) TERMINATE VENT 1' ABOVE FAN AND PAINT 3) ALSO NEED TO SEE CONNECTION TO SEWER 4) NEED TO SEE PERMANENT CAP ON ABANDON SEWER |
| 12/21/2007 | PLUMBING - PROGRESS | BBENEDON | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
| 01/07/2008 | MECHANICAL - PROGRESS | JMILITEL | Approved | IVRS - Inspection :* |
| 01/22/2008 | SHEET ROCK NAILING | JBURGE | Approved | IVRS - Inspection :* OK TO TAPE |
| 03/05/2008 | MECHANICAL - INTERMEDIATE | JMILITEL | Approved | IVRS - Inspection :* - ON FINAL TERMINATE CONDENSATE TO AN AREA THAT CAN ABSORB THE WATER. - PERMANENTLY I.D AC UNITS - MARK UNIT DATA PLATES & FUSE ACCORDINGLY - PAINT EXPOSED PVC W/LATEX PAINT - PROVIDE AIR BALANCE REPORT |
| 03/25/2008 | TEP CLEARANCE - AM | JWEATHER | Approved | TMPP CLEARED PER R. HOLLANDER-2ND TIME SENT TO TEP |
| 03/25/2008 | TEP CLEARANCE - AM | JWEATHER | Approved | TMPP CLEARED PER R. HOLLANDER ON 3/20/08-AM |
| 04/01/2008 | PLUMBING - FINAL | RMYERS | Approved | IVRS - Inspection :* |
| 04/04/2008 | MECHANICAL - FINAL | JMILITEL | Approved | IVRS - Inspection :* |
| 04/04/2008 | ELECTRIC - UFER | RHOLLAND | Approved | |
| 04/04/2008 | ELECTRIC - FINAL | RHOLLAND | Approved | IVRS - Inspection :* |
| 04/04/2008 | ELECTRIC - PROGRESS | RHOLLAND | Approved | IVRS - Inspection :* |
| 04/04/2008 | ELECTRIC - RECONNECT | RHOLLAND | Approved | IVRS - Inspection :* |
| 04/04/2008 | ELECTRIC - SERVICE UPGRADE | RHOLLAND | Approved | IVRS - Inspection :* |
| 04/04/2008 | ELECTRIC - TEMP POWER FOR TEST | RHOLLAND | Approved | IVRS - Inspection :* |
| 04/04/2008 | ELECTRIC - INTERMEDIATE | RHOLLAND | Approved | IVRS - Inspection :* |
| 04/08/2008 | NPPO - FINAL | ACONNOR | Approved | N/A |
| 04/08/2008 | LANDSCAPE - FINAL | ACONNOR | Approved | N/A |
| 04/08/2008 | SIGN - FINAL | JYBARRA | Approved | NO SIGNS AT THIS TIME |
| 05/07/2008 | BUILDING - FINAL | JBURGE | Approved | IVRS - Inspection :* MOVE ADA PARKING SIGN TO 84" ABOVE GROUND @ BOTTOM OF SIGN |
| 05/07/2008 | FIRE - FINAL | CSCHULTZ | Approved | |
| 05/29/2008 | RIGHT OF WAY - FINAL | PWHIDDON | Approved | PER EMAIL |
| 06/04/2008 | ENGINEERING - FINAL | JBRUCKME | Approved |