Permit Details

Status:
C of o
Type:
COMMERCIAL ALTERATION
Address NEW:
4670 N CIRCUIT RD 01
Apply Date:
03/21/2007
Applicant:
N/A
Description:
TI:OFFICE
Contractors:
  • GILES CONSTRUCTION INC

Permit Reviews

Permit Number - T07CM01144
Permit Status: C of o
Permit Description: TI:OFFICE
Start Date Submittal Complete Date Status  
03/21/2007 PLANS OK TO SUBMIT - 3RD PARTY 03/22/2007 COMPLETED Review Details
03/22/2007 3RD PARTY REVIEW-COMMERCIAL TI 05/08/2007 COMPLETED Review Details
05/08/2007 POST 3RD PARTY REVIEW 02/26/2008 COMPLETED Review Details
05/12/2008 3RD PARTY REVIEW-REVISION/OTHER 05/19/2008 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T07CM01144
Permit Status: C of o
Permit Description: TI:OFFICE
Total Outstanding Activity Conditions - 1
Date Name
03/21/2007 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: C of o
Permit Number: T07CM01144
Permit Description: TI:OFFICE
Total Completed Inspections - 25
Date Description Inspector Results Comments
05/13/2008 FRAMING AQUIROZ Approved IVRS - Inspection :*
05/14/2008 MECHANICAL - INTERMEDIATE MRAMBER Approved IVRS - Inspection :*
05/18/2008 SHEET ROCK NAILING AQUIROZ Approved IVRS - Inspection :*
06/02/2008 BUILDING ABOVE CEILING AQUIROZ Approved IVRS - Inspection :*
06/02/2008 MECHANICAL - ABOVE CEILING MRAMBER Approved IVRS - Inspection :*
06/02/2008 PLUMBING - GAS PRESSURE TEST RMYERS Approved IVRS - Inspection :*
06/02/2008 PLUMBING - ABOVE CEILING RMYERS Approved IVRS - Inspection :*
06/02/2008 PLUMBING - INTERMEDIATE RMYERS Approved IVRS - Inspection :*
06/02/2008 PLUMBING - ROUGH, SOIL RMYERS Approved IVRS - Inspection :*
06/10/2008 FIRE SPKLR - FINAL LTHOMAS Approved
06/10/2008 FIRE - FINAL LTHOMAS Approved
06/11/2008 RIGHT OF WAY - FINAL MOTERO Approved PER EMAIL R/W ends at BOC
06/11/2008 NPPO - FINAL ACONNOR Approved N/A
06/11/2008 LANDSCAPE - FINAL ACONNOR Approved N/A
06/12/2008 ENGINEERING - FINAL MRUSSO Approved
06/13/2008 ELECTRIC - FINAL CCLEMENS Approved IVRS - Inspection :*
1. REMOVE SYSTEM BONDING JUMPER PANEL P3 -
NEC 250.30 A1
2. SERVER ROOM EMERGENCY LIGHT NOT WORKING
3. STAIRWELL EXIT SIGN NOT WORKING

TALK WITH ELECTRICAL CONTRACTOR AND HE WILL CORRECT
06/13/2008 MECHANICAL - FINAL MRAMBER Approved IVRS - Inspection :*
06/13/2008 ELECTRIC - ABOVE CEILING CCLEMENS Approved IVRS - Inspection :*
06/13/2008 ELECTRIC - INTERMEDIATE CCLEMENS Approved IVRS - Inspection :*
06/16/2008 PLUMBING - FINAL RMYERS Approved IVRS - Inspection :*
PLUMBING FINAL APPROVED
BLDG FINAL APPROVED
06/16/2008 BUILDING - FINAL RMYERS Approved IVRS - Inspection :*
06/16/2008 BUILDING - FINAL LHANLY Approved IVRS - Inspection :*
06/16/2008 PLUMBING - FINAL RMYERS Approved IVRS - Inspection :*
1. INSTALL MIXING VALVES AT LAVATORIES IN A WORKMANSHIP LIKE MANNER
2. PIPING HAS COME LOOSE IN THE WALL
3. PROVIDE LISTING FOR HAMMER ARRESTOR TO BE INSTALLED HORIZONTALLY
06/16/2008 PLUMBING - GAS PRESS TEST FNL RMYERS Approved IVRS - Inspection :*
07/08/2008 SIGN - FINAL JYBARRA Approved IVRS - Inspection :*

Documents

File Name Document Type  
C OF O_07-14-2008.TIF CERT OF OCC VIEW
001__T1.TIF CONSTRPLANS VIEW
002__A2.TIF CONSTRPLANS VIEW
003__CO.TIF CONSTRPLANS VIEW
004__A3.TIF CONSTRPLANS VIEW
005__A1.TIF CONSTRPLANS VIEW
006__P1.TIF CONSTRPLANS VIEW
007__P2.TIF CONSTRPLANS VIEW
008__M1.TIF CONSTRPLANS VIEW
009__M2.TIF CONSTRPLANS VIEW
010__MP1.TIF CONSTRPLANS VIEW
011__E0.1.TIF CONSTRPLANS VIEW
012__E1.1.TIF CONSTRPLANS VIEW
T07CM01144_001.TIF CONSTRPLANS VIEW
T07CM01144_002.TIF CONSTRPLANS VIEW
T07CM01144_003.TIF CONSTRPLANS VIEW
T07CM01144_004.TIF CONSTRPLANS VIEW
T07CM01144_005.TIF CONSTRPLANS VIEW
T07CM01144_006.TIF CONSTRPLANS VIEW
T07CM01144_007.TIF CONSTRPLANS VIEW
T07CM01144_008.TIF CONSTRPLANS VIEW
T07CM01144_009.TIF CONSTRPLANS VIEW
T07CM01144_010.TIF CONSTRPLANS VIEW
T07CM01144_011.TIF CONSTRPLANS VIEW
T07CM01144_012.TIF CONSTRPLANS VIEW
None DOCUMENTS VIEW