Permit: T07CM00918
Permit Details
Status:
C of o
Type:
COMMERCIAL NEW
Address:
7313 E TANQUE VERDE RD
Address NEW:
7313 E TANQUE VERDE RD
Apply Date:
03/07/2007
Applicant:
N/A
Description:
NEW VETERINARY CLINIC
Contractors:
- VENTURE WEST INC *C
Permit Reviews
Permit Number - T07CM00918
Permit Status: C of o
Permit Description: NEW VETERINARY CLINIC
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 03/07/2007 | PLANS OK TO SUBMIT - 3RD PARTY | 03/08/2007 | COMPLETED |
| 03/08/2007 | 3RD PARTY REVIEW-COMMERCIAL | 05/09/2007 | COMPLETED |
| 05/09/2007 | POST 3RD PARTY REVIEW | 05/24/2007 | COMPLETED |
| 05/24/2007 | POST 3RD PARTY REVIEW | 05/25/2007 | COMPLETED |
| 06/12/2007 | 3RD PARTY REVIEW-REVISION/OTHER | 07/31/2007 | COMPLETED |
| 07/31/2007 | 3RD PARTY REVIEW-REVISION/OTHER | 08/17/2007 | COMPLETED |
| 08/10/2007 | 3RD PARTY REVIEW-REVISION/OTHER-2ND | 08/17/2007 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T07CM00918
Permit Status: C of o
Permit Description: NEW VETERINARY CLINIC
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 03/07/2007 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T07CM00918
Permit Description: NEW VETERINARY CLINIC
Total Completed Inspections - 52
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/11/2007 | SITE - SEWER | BBENEDON | Approved | IVRS - Inspection :* |
| 06/11/2007 | PLUMBING - ROUGH, SOIL | BBENEDON | Approved | IVRS - Inspection :* |
| 06/27/2007 | ELECTRIC - UFER | RHOLLAND | Approved | IVRS - Inspection :* OK 3/0 & #6 TO REBAR |
| 06/28/2007 | BUILDING PRE-SLAB | JBURGE | Approved | IVRS - Inspection :* OK TO POUR SLAB |
| 06/28/2007 | EXCAVATION/LAYOUT REBAR & ZON | JBURGE | Approved | IVRS - Inspection :* OK TO POUR CONTINUOUS FOOTINGS |
| 07/17/2007 | REINFORCED MASONRY PRE-GROUT | JBURGE | Approved | IVRS - Inspection :* EAST & SOUTHEAST WALLS TOPPED OUT @ 18' |
| 08/16/2007 | ROOF NAILING | JBURGE | Approved | IVRS - Inspection :* OK TO DRY IN |
| 08/20/2007 | ELECTRIC - UNDERGROUND | RHOLLAND | Approved | IVRS - Inspection :* 1) OK 2-4" PVC EXISTING TO BLDG |
| 08/22/2007 | BUILDING - PROGRESS | JBURGE | Approved | IVRS - Inspection :* 6 @ DOG RUNS; 7' CMU WALLS AS PER RFI OPTION #1 REBAR PLACED PER OPTION 1 OK TO POUR WALLS |
| 08/29/2007 | EXT METAL CLIPS/EXT SHEATHING | JBURGE | Approved | IVRS - Inspection :* OK TO COVER EXTERIOR SHEATHING |
| 08/29/2007 | PLUMBING - YARD WTR LINE/TEST | RLEDONNE | Approved | IVRS - Inspection :* PER REDLINE DRAWING TEST UP TO VALVE AT BUILDING OK |
| 09/05/2007 | ELECTRIC - OUTDOOR LIGHTING | RHOLLAND | Approved | IVRS - Inspection :* OK SOFFIT CANS 1. DO NOT COVER WITHOUT INSPECTIONS |
| 09/10/2007 | PLUMBING - MD GAS/PRECONST MTG | BBENEDON | Approved | IVRS - Inspection :* STEVE W/CACTUS DONNIE W/AZ PRO. ROBERT JOINED US DURING INSP. LONNIE & SHERRI W/VENTURE WEST SPECIAL INSPECTORS PRESENTS REQUIRED FOR PRE-CON INSTALLERS PRESENT FOR PRE-CON ONLY INSTALLER MAY INSTALL PIPING HELPER MAY NOT ASSEMBLE PIPE |
| 09/12/2007 | FRAMING | JBURGE | Approved | IVRS - Inspection :* OK TO SHEETROCK ONE SIDE |
| 09/12/2007 | PLUMBING - ROOF DRAINS | BBENEDON | Approved | IVRS - Inspection :* |
| 09/13/2007 | PLUMBING - INTERMEDIATE | BBENEDON | Approved | IVRS - Inspection :* - REDLINE CHANGES AT AAV AND DF - PLAN REVISION REQUIRED AT DF - OK TO COVER SUBJECT TO REVISION AND APPROVAL OF MED GAS TEST |
| 09/13/2007 | PLUMBING - MEDICAL GAS/TEST | BBENEDON | Approved | IVRS - Inspection :* |
| 09/20/2007 | STUCCO MESH | JBURGE | Approved | IVRS - Inspection :* 1) OK TO STUCCO |
| 09/24/2007 | MECHANICAL - INTERMEDIATE | JMILITEL | Approved | IVRS - Inspection :* SUPPLY & EXHAUST IN RESTROOMS OK TO COVER CHECKED CONDENSATE DRAIN LINES |
| 10/10/2007 | SHEET ROCK NAILING | JBURGE | Approved | IVRS - Inspection :* OK TO TAPE THROUGHOUT |
| 12/03/2007 | MECHANICAL - ABOVE CEILING | JMILITEL | Approved | IVRS - Inspection :* OK FOR CEILING TILES |
| 12/03/2007 | BUILDING ABOVE CEILING | JBURGE | Approved | IVRS - Inspection :* OK TO SET TILES |
| 12/11/2007 | ELECTRIC - TEMP POWER FOR TEST | RHOLLAND | Approved | IVRS - Inspection :* |
| 12/12/2007 | TEP CLEARANCE - AM | JWEATHER | Approved | TMPP CLEARED PER R. HOLLANDER |
| 12/13/2007 | PLUMBING - ABOVE CEILING | BBENEDON | Approved | IVRS - Inspection :* NO CHANGE SINCE LAST INSP. COMPLETE MEDICAL GAS PIPING AND PIPE LABELS. OTHER AREAS OK TO COVER |
| 12/14/2007 | ELECTRIC - ABOVE CEILING | RHOLLAND | Approved | IVRS - Inspection :* OK TO TILE EXCEPT AS NOTED 1. NEED TO SEE CONNECTIONS OF SURGERY LIGHTS |
| 12/19/2007 | ELECTRIC - INTERMEDIATE | RHOLLAND | Approved | IVRS - Inspection :* OK RECEPT COUNTER |
| 01/16/2008 | MECHANICAL - FINAL | JMILITEL | Approved | IVRS - Inspection :* AIR BALANCE OK |
| 01/16/2008 | MECHANICAL - PROGRESS | JMILITEL | Approved | IVRS - Inspection :* |
| 01/16/2008 | MECHANICAL - HOOD SYSTEMS | JMILITEL | Approved | IVRS - Inspection :* |
| 01/16/2008 | U VALUE FOR WINDOW | JBURGE | Approved | IVRS - Inspection :* TEMPERED THERMAL PANE SYSTEM |
| 01/16/2008 | PLUMBING - PROGRESS | BBENEDON | Approved | IVRS - Inspection :* |
| 01/16/2008 | PLUMBING - PRE SLAB | BBENEDON | Approved | IVRS - Inspection :* |
| 01/16/2008 | SIGN - FINAL | JYBARRA | Approved | IVRS - Inspection :* |
| 01/16/2008 | NPPO - FINAL | ACONNOR | Approved | N/A |
| 01/16/2008 | LANDSCAPE - FINAL | ACONNOR | Approved | N/A |
| 01/16/2008 | FIRE SPKLR - UG PIPING FLUSH | LTHOMAS | Approved | |
| 01/16/2008 | FIRE SPKLR - OH PIPING & HYDRO | LTHOMAS | Approved | |
| 01/16/2008 | FIRE SPKLR - FINAL | LTHOMAS | Approved | |
| 01/16/2008 | FIRE SPKLR - UG, PIPING, HYDRO | LTHOMAS | Approved | |
| 01/16/2008 | FIRE - FINAL | LTHOMAS | Approved | |
| 01/16/2008 | RIGHT OF WAY - FINAL | PWHIDDON | Approved | PER EMAIL |
| 01/18/2008 | PLUMBING - FINAL | BBENEDON | Approved | IVRS - Inspection :* |
| 01/18/2008 | PLUMBING - MEDICAL GAS/FINAL | BBENEDON | Approved | IVRS - Inspection :* |
| 01/18/2008 | OUTDOOR LIGHTING FINAL | RHOLLAND | Approved | IVRS - Inspection :* |
| 01/18/2008 | ELECTRIC - FINAL | RHOLLAND | Approved | IVRS - Inspection :* |
| 01/18/2008 | ELECTRIC - PROGRESS | RHOLLAND | Approved | IVRS - Inspection :* |
| 01/18/2008 | ELECTRIC - TEMPORARY SERVICE | RHOLLAND | Approved | IVRS - Inspection :* |
| 01/18/2008 | ELECTRIC - CABLE DROP | RHOLLAND | Approved | IVRS - Inspection :* |
| 02/14/2008 | BUILDING - FINAL | JBURGE | Approved | IVRS - Inspection :* ALL NOTED CORRECTIONS COMPLETE |
| 03/21/2008 | ENGINEERING - FINAL | JBRUCKME | Approved | APPROVED ON CONDITION, NO OTHER C OF O'S WILL BE GRANTED UNTIL FINAL GRADING INSPECTION APPROVAL. Tanque Verde Place T04BU02272 Preliminary Grading Punch list March 20, 2008 The following item must be completed prior to final approval of the grading permit and Certificate of Occupancy for lots 9, 10, 32-37 AND ALL LOTS OUTSTANDING. 1. Construct all sidewalks as shown on the approved plans. 2. Construct all sidewalk scuppers per approved plans. 3. Construct drainage swale behind lots 44-47 per plan. 4. Clean drainage pipe behind lots 28, 29. 5. Grout rip rap outfalls per approved plan. 6. Install concrete gutters or revise plan. 7. Revise the grading plan per red line drawings. 8. Install stop signs per plan. 9. Expose all storm drain manhole covers. 10. Submit an Engineers certification for lots 1-14. 11. Repair/ replace all broken or damaged sidewalk and ramps that have two or more through cracks per panel. 12. Trim basin and swale slopes to match plan grades and cross section. 13. Show slope grades at southeast side of lot 57. Slopes steeper then 2:1 require grouted rip rap. 14. Covered parking canopies extend 1 foot into the required PAAL. Have Engineer address with Zoning. 15. Provide detail for both type I and II bicycle parking, and provide lighting as noted on approved plan. 16. Show location of all handrails on as-built plan. 17. Provide inlet and outlet flow line elevation for all underground pipe. 18. Provide detail for drainage swale along west edge of property. Sidewalk/porch extends into area for swale. 19. Insure a minimum of 4 ft sidewalk clearance at building pop outs, electrical panels, etc. 20. Insure a minimum 24 ft PAAL at lot 2. 21. Insure water does not pond at all curb ramps. 22. Provide type B post barricades in trash enclosures per approved plan. Please address above items and call for reinspection. |
| 03/26/2008 | PERMIT FINALED | LJACKSON | Approved |