Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Final
Type:
SINGLE FAMILY OTHER
Address:
2910 E 23RD ST
Address NEW:
2910 E 23RD ST
Apply Date:
09/19/2006
Applicant:
SYLVIA RAMOS
Description:
REPL GAS LINE & WATER HEATER

Outstanding Activity Conditions

Permit Number - T06PL01679
Permit Status: Final
Permit Description: REPL GAS LINE & WATER HEATER
Total Outstanding Activity Conditions - 1
Date Name
09/19/2006 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: Final
Permit Number: T06PL01679
Permit Description: REPL GAS LINE & WATER HEATER
Total Completed Inspections - 3
Date Description Inspector Results Comments
10/11/2006 PLUMBING - FINAL BBENEDON Approved IVRS - Inspection :
See detailed listing on site.| 999*
- THE ENTIRE GAS SYSTEM SHALL BE BROUGHT UP TO CURRENT CODE REQUIREMENTS.
- THE INSTALLATION AND RELOCATION OF NEW HEAT PUMP AND INSTANTANEOUS WH REQUIRE SEPARATE PERMITS.
- OBTAIN A MECHANICAL PERMIT AND HAVE FURNACE INSPECTED PRIOR TO GAS PIPING INSPECTION.
- ALSO, PROVIDE PROOF OF STRUCTURAL FRAMING INSPECTION FOR NEW ROOF. NOTE: PLUMBING VENTS NEED TO TERMINATE ABOVE NEW ROOF.
- 3/4" GAS PIPING TO 199,000 BTU WH AND 69,000 BTU FURNACE, STOVE AND DRYER IS UNDERSIZED. PLEASE PROVIDE A CITY APPROVED ISOMETRIC DRAWING OF GAS SYSTEM.
- OLD FURNACE & PIPING SHALL BE REMOVED IF NOT OPERABLE
- VENTING ON WH NOT CORRECTLY INSTALLED
- BELOW GRADE PIPING SHALL BE PRIMERED AND WRAPPED AT FITTINGS & TEST MARKS, 15 PSI GAUGE REQUIRED FOR TEST.
10/11/2006 PLUMBING - GAS PRESSURE TEST BBENEDON Approved IVRS - Inspection :
See detailed listing on site.| 999*
05/01/2007 PERMIT FINALED BFLORES Approved

Documents

File Name Document Type  
None DOCUMENTS VIEW
None CONSTRPLANS VIEW