Permit: T06PL01679
Permit Details
Apply Date:
09/19/2006
Applicant:
SYLVIA RAMOS
Description:
REPL GAS LINE & WATER HEATER
Outstanding Activity Conditions
Permit Number - T06PL01679
Permit Status: Final
Permit Description: REPL GAS LINE & WATER HEATER
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 09/19/2006 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T06PL01679
Permit Description: REPL GAS LINE & WATER HEATER
Total Completed Inspections - 3
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/11/2006 | PLUMBING - FINAL | BBENEDON | Approved | IVRS - Inspection : See detailed listing on site.| 999* - THE ENTIRE GAS SYSTEM SHALL BE BROUGHT UP TO CURRENT CODE REQUIREMENTS. - THE INSTALLATION AND RELOCATION OF NEW HEAT PUMP AND INSTANTANEOUS WH REQUIRE SEPARATE PERMITS. - OBTAIN A MECHANICAL PERMIT AND HAVE FURNACE INSPECTED PRIOR TO GAS PIPING INSPECTION. - ALSO, PROVIDE PROOF OF STRUCTURAL FRAMING INSPECTION FOR NEW ROOF. NOTE: PLUMBING VENTS NEED TO TERMINATE ABOVE NEW ROOF. - 3/4" GAS PIPING TO 199,000 BTU WH AND 69,000 BTU FURNACE, STOVE AND DRYER IS UNDERSIZED. PLEASE PROVIDE A CITY APPROVED ISOMETRIC DRAWING OF GAS SYSTEM. - OLD FURNACE & PIPING SHALL BE REMOVED IF NOT OPERABLE - VENTING ON WH NOT CORRECTLY INSTALLED - BELOW GRADE PIPING SHALL BE PRIMERED AND WRAPPED AT FITTINGS & TEST MARKS, 15 PSI GAUGE REQUIRED FOR TEST. |
| 10/11/2006 | PLUMBING - GAS PRESSURE TEST | BBENEDON | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
| 05/01/2007 | PERMIT FINALED | BFLORES | Approved |