Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T06PL00667
Permit Details
Apply Date:
04/25/2006
Applicant:
KBP ARCHITECTURE LLC
Description:
NEW GAS LINE INSTALLATION
Contractors:
- M L COLLINS INC /PLUMB HAPPY *C
Permit Reviews
Permit Number - T06PL00667
Permit Status: Final
Permit Description: NEW GAS LINE INSTALLATION
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
04/25/2006 | PLUMBING | 04/25/2006 | COMPLETED |
09/28/2007 | PLUMBING | 09/28/2007 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T06PL00667
Permit Status: Final
Permit Description: NEW GAS LINE INSTALLATION
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
04/25/2006 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T06PL00667
Permit Description: NEW GAS LINE INSTALLATION
Total Completed Inspections - 3
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/21/2007 | PLUMBING - GAS PRESSURE TEST | RRICH | Approved | WILL BE REOPENED FOR GAS PIPING TEST, SYSTEM WILL BE RETESTED WHEN CORRECT REGULATION OF 5 PSI GAS TO CORRECT PRESSURES AT EACH APPLIANCE IS ACHEIVED AND VERIFIED. ALL REGUALTORS SHALL BE LABELED PROPERLY PER SECTION 1209.7.7 2006 UPC. ALL VENTS FROM REGULATORS TO BE FULL SIZE PIPING PROPERLY TERMINATED PER SECTION 1209.7.5 OF 2006 UPC AND NFPA 54:.8.5.1 WITH CORRECT DISTANCE FROM INTAKES AND SOURCES OF IGNITATION. ALL VENT TERMINATIONS SHALL PREVENT ON TRY OF WATER, INSECTS AND OTHER FOREIGN MATERIALS. TUCSON PLUMBING IS CONTRACTOR OF RECORD TO BE CHANGED ON THIS PERMIT ACTIVITY PLEASE PROVIDE A QUALIFIED REPRESENTATIVE TO VERIFY AND START UP ALL EQUIPMENT |
12/21/2007 | PLUMBING - FINAL | RRICH | Approved | IVRS - Inspection :* |
02/21/2008 | PERMIT FINALED | BFLORES | Approved |