Permit: T06PL00467
Permit Details
Status:
Expired
Type:
SINGLE FAMILY OTHER
Address:
8820 E SHENANDOAH PL
Address NEW:
8820 E SHENANDOAH PL
Apply Date:
03/17/2006
Applicant:
TAMAYO JESUS EDUARDO PENNOCK &
Description:
GAS RECONNECT
Outstanding Activity Conditions
Permit Number - T06PL00467
Permit Status: Expired
Permit Description: GAS RECONNECT
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 03/17/2006 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T06PL00467
Permite Description: GAS RECONNECT
Total Outstanding Inspections - 3
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/20/2006 | PLUMBING - GAS PRESS TEST FNL | N/A | Not ready for Inspection | IVRS - Inspection :* 1. VENT FROM WATER HEATER & FURNACE TO BE MADE UP CORRECTLY AND HAVE 3-GALV SCREWS AT EACH JOINT OF FLUE VENT PIPE. 2. PROVIDE RIDGID PIPE THRU FURNACE APPLIANCE HOUSING. 3. SECURE GAS PIPING IN FURNACE/WATER HEATER CLOSET 4. PROVIDE BONDING OF BUILDING GAS PIPING. MAKE CORRECTIONS AND PROVIDE RETEST OF GAS SYSTEM THIS IS NOT A RECONNECT. |
| 03/22/2006 | PLUMBING - GAS PRESSURE TEST | N/A | Partial Approval | 15 PSI TEST OVERHEAD TO FURNACE & WATER HEATER ONLY OK |
| 03/23/2006 | PLUMBING - FINAL | N/A | Not ready for Inspection | 1. SEE NOTES FROM 3/17/06 INSPECTION WATER HEATER TEMPERATURE & PRESSURE RELIEF CANNOT GO UP THRU ROOF. SEE NOTES ABOUT VENT TERMINATION FROM WATER HEATER & FURNACE. SEE NOTE #4 FROM 3/17/06 INSPECTION. |
Completed Inspections
Permit Status: Expired
Permit Number: T06PL00467
Permit Description: GAS RECONNECT
Total Completed Inspections - 1
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/24/2006 | PLUMBING - GAS RECONNECT | JMILITEL | Approved | IVRS - Inspection :* 14 PSI TEST IS OK LEFT GAS CARD CORRECTIONS HAVE BEEN MADE |