Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Final
Type:
COMMERCIAL OTHER
Apply Date:
02/16/2006
Applicant:
AC ARTISANS ELECTRICAL CONT *T
Description:
UPGR: ELEC 200 AMP (APA)
Contractors:
  • AC ARTISANS ELECTRICAL CONT *T

Permit Reviews

Permit Number - T06EL00321
Permit Status: Final
Permit Description: UPGR: ELEC 200 AMP (APA)
Start Date Submittal Complete Date Status  
04/25/2007 ELECTRICAL 04/25/2007 COMPLETED Review Details
11/21/2007 OTHER 11/26/2007 COMPLETED Review Details
12/14/2007 ELECTRICAL 12/14/2007 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T06EL00321
Permit Status: Final
Permit Description: UPGR: ELEC 200 AMP (APA)
Total Outstanding Activity Conditions - 1
Date Name
02/16/2006 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: Final
Permit Number: T06EL00321
Permit Description: UPGR: ELEC 200 AMP (APA)
Total Completed Inspections - 5
Date Description Inspector Results Comments
04/30/2007 ELECTRIC - INTERMEDIATE RMAJUTA Approved IVRS - Inspection :*
10/10/2007 ELECTRIC - FINAL RJIROUDE Approved IVRS - Inspection :
See detailed listing on site.| 999*
1. CHECK OUTDOOR GFI RECEPTACLES SECURED TO BUILDING SURFACE
2. INSTALL MISSING DEVICE PLATES
3. INSTALL FIXTURE TRIMS
4. CHECK WATTAGE ON CLOSET LAMPS
5. OPEN GROUND ON GFI RECEPT KITCHEN
6. OUTDOOR WALL SCONCE INSTALLED UPSIDE DOWN
7. INSTALL DISPOSAL
8. FINISH SHEET ROCKING
9. FINISH KITCHEN ISLAND & INSTALL ISLAND RECEPTACLES
10. SMOKE DETECTORS TO BE INTERCONNECTED
11. LABEL ALL CIRCUITS AT PANEL
12. INSTALL FILLER PLATES ON OPEN BREAKER POSITION AT PANEL
13. SMOKE DETECTOR CIRCUIT TO BE AFCI
14. WIRING IN ATTIC NOT PER CODE
15. INSTALL K.O SEALS IN JUNCTION BOXES
16. NEED TO DERATE CONDUCTORS IN 1 1/2" EMT TO JUNCTION BOXES IN ATTIC
17. INSTALL SERVICE RECEPTACLE FOR AC UNIT
18. PROVIDE PAPERWORK/PREVIOUS INSPECTONS SHOWING OUTDOOR LIGHTING RACEWAYS INSPECTED
19. GENERAL LIGHTING & GATE OPERATURE SHOULD BE ON HOUSE PANEL NOT TENANTS PANEL
20. GROUND ALL METAL BOXES
01/04/2008 TEP CLEARANCE - AM JWEATHER Approved INCR CLEARED FOR #1 PER R. MAJUTA
03/12/2008 ELECTRIC - SERVICE UPGRADE RMAJUTA Approved
03/13/2008 PERMIT FINALED JWEATHER Approved

Documents

File Name Document Type  
None CONSTRPLANS VIEW
None DOCUMENTS VIEW