Permit: T06CM06548
Permit Details
Status:
Expired
Type:
COMMERCIAL OTHER
Address:
6541 S CAMINO DE LA TIERRA
Address NEW:
6541 S CAMINO DE LA TIERRA
Apply Date:
12/28/2006
Applicant:
DORATHY DOLAN - TUCSON WATER
Description:
BOOSTER STATION (TUCSON WATER)
Contractors:
- P AND H CONTRACTING INC ,
Permit Reviews
Permit Number - T06CM06548
Permit Status: Expired
Permit Description: BOOSTER STATION (TUCSON WATER)
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 12/28/2006 | PLANS OK TO SUBMIT - COMM | 12/28/2006 | COMPLETED |
| 12/28/2006 | COMMERCIAL NEW | 03/09/2007 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T06CM06548
Permit Status: Expired
Permit Description: BOOSTER STATION (TUCSON WATER)
Total Outstanding Activity Conditions - 5
| Date | Name |
|---|---|
| 12/28/2006 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
| 01/29/2007 | SPECIAL INSPECTION FOR CONCRETE IS REQUIRED.. |
| 01/29/2007 | SPECIAL INSPECTION FOR STRUCTURAL MASONRY IS REQUIRED. |
| 01/29/2007 | SPECIAL INSPECTION FOR REINFORCING STEEL AND PRE-STRESSING TENDONS IS REQUIRED PER U.A.C SECTION 306. |
| 04/17/2007 | 1) DS Sec.10-02.2.3.1.2.F: All conditions of the PCFCD Permit (FPUP) No.06-613 apply. 2) DS Sec.10-02.2.3.1.2.F.1: Submit a copy of the PCFCD accepted as-built certification letter from an Arizona registered Civil Engineer as required per the Pima County Floodplain Use Permit to the City of Tucson Development Services Engineering Division Floodplain. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T06CM06548
Permite Description: BOOSTER STATION (TUCSON WATER)
Total Outstanding Inspections - 3
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| ELECTRIC - UFER | N/A | Not Inspected | ||
| 10/11/2007 | ELECTRIC - CABLE DROP | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. APPROVED PLANS CALL FOR NEUTRAL CONDUCTOR TO BE INSTALLED AT SERVICE EQUIP. SEE SHEET 19 2. NEC REQUIRES NEUTRAL PER 250.4 A-5, 250.24 B 3. PROVIDE LETTER OF TORQUE FOR SERVICE EQUIP. |
| 10/25/2007 | ELECTRIC - FINAL | N/A | Partial Approval | IVRS - Inspection :* CALL FOR FINAL POWER CHECKED BY CONTR. |
Completed Inspections
Permit Status: Expired
Permit Number: T06CM06548
Permit Description: BOOSTER STATION (TUCSON WATER)
Total Completed Inspections - 13
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/02/2007 | EXCAVATION/LAYOUT REBAR & ZON | AALEGRIA | Approved | IVRS - Inspection :* |
| 04/05/2007 | BUILDING PRE-SLAB | AALEGRIA | Approved | IVRS - Inspection :* |
| 06/04/2007 | ROOF NAILING | AALEGRIA | Approved | IVRS - Inspection :* IN ACCORDANCE WITH APPROVED PLANS AND SPECIFIC REQ. ON SHEET 14 AND GENERAL NOTES REGARDING ALT. #5 @ 12" O.C E.W SPECIAL INSPECTION REPORT IN COMPLIANCE OK TO POUR |
| 06/04/2007 | REINFORCED MASONRY PRE-GROUT | AALEGRIA | Approved | IVRS - Inspection :* |
| 10/25/2007 | BUILDING - FINAL | JBURGE | Approved | IVRS - Inspection :* PENDING ELECTRIC POWER CHECK |
| 10/25/2007 | STEM WALL/RETAINING WALL | JBURGE | Approved | |
| 10/25/2007 | ELECTRIC - OUTDOOR LIGHTING | DSANTACR | Approved | IVRS - Inspection :* |
| 10/25/2007 | ELECTRIC - SERVICE UPGRADE | DSANTACR | Approved | IVRS - Inspection :* |
| 10/25/2007 | ELECTRIC - TEMP POWER FOR TEST | DSANTACR | Approved | IVRS - Inspection :* |
| 10/25/2007 | ELECTRIC - ABOVE CEILING | DSANTACR | Approved | IVRS - Inspection :* |
| 10/25/2007 | ELECTRIC - INTERMEDIATE | DSANTACR | Approved | IVRS - Inspection :* |
| 10/25/2007 | ELECTRIC - UNDERGROUND | DSANTACR | Approved | IVRS - Inspection :* |
| 10/26/2007 | TEP CLEARANCE - AM | JWEATHER | Approved | TEC CLEARED PER D. SANTACRUZ |