Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
C of o
Type:
COMMERCIAL ALTERATION
Apply Date:
11/30/2006
Applicant:
ISLES, SCOTT EMORY
Description:
TI: ACCOUNTING OFFICE REVISION 1 DELTA 1 CLARIFICATION OF ACCESSIBLE RESTROOM ONLY
Architects:
  • ISLES, SCOTT EMORY
Contractors:
  • WARRIOR CONSTRUCTION L L C

Permit Reviews

Permit Number - T06CM06118
Permit Status: C of o
Permit Description: TI: ACCOUNTING OFFICE REVISION 1 DELTA 1 CLARIFICATION OF ACCESSIBLE RESTROOM ONLY
Start Date Submittal Complete Date Status  
01/12/2007 REVISION - - 1ST 01/12/2007 COMPLETED Review Details
11/30/2006 COMMERCIAL TI 12/01/2006 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T06CM06118
Permit Status: C of o
Permit Description: TI: ACCOUNTING OFFICE REVISION 1 DELTA 1 CLARIFICATION OF ACCESSIBLE RESTROOM ONLY
Total Outstanding Activity Conditions - 1
Date Name
11/30/2006 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: C of o
Permit Number: T06CM06118
Permit Description: TI: ACCOUNTING OFFICE REVISION 1 DELTA 1 CLARIFICATION OF ACCESSIBLE RESTROOM ONLY
Total Completed Inspections - 10
Date Description Inspector Results Comments
12/21/2006 BUILDING - FINAL LHANLY Approved IVRS - Inspection :
See detailed listing on site.| 999*
1. 12" ADDRESS DISPLAY REQUIRED PER PCZO
2. 3" SUITE # REQUIRED
3. SPLIT FRONT TOILET SEATS REQUIRED
4. MAX HEIGHT OF ACCESSIBLE LAVATORY IS 34"
5. GRAB BARS PER ANSI 117.1 REQUIRED
6. PLAN SHOWS INCORRECT BATHROOM AS ACCESSIBLE
7. SIGNAGE PER CHAPTER 11 IBC MISSING
8. LEVER HANDLE HARDWARE REQUIRED ON ACCESSIBLE DOORS.
9. THRESHOLDS ON ACCESSIBLE ROUTES TO MEET
CHAPTER 11 IBC REQUIREMENTS.
12/21/2006 RIGHT OF WAY - FINAL LLOPEZ Approved TEMP ONLY
12/21/2006 ENGINEERING - FINAL MAVERY Approved
12/21/2006 CERTIFICATE OF OCCUPANCY LHANLY Approved IVRS - Inspection :
See detailed listing on site.| 999*
12/21/2006 NPPO - FINAL ACONNOR Approved
12/21/2006 LANDSCAPE - FINAL ACONNOR Approved
12/21/2006 SIGN - FINAL JYBARRA Approved IVRS - Inspection :*
12/21/2006 FIRE - FINAL LTHOMAS Approved
12/26/2006 ELECTRIC - OUTDOOR LIGHTING DSANTACR Approved
12/26/2006 ELECTRIC - FINAL DSANTACR Approved

Documents

File Name Document Type  
C OF O_05-01-2009.TIF CERT OF OCC VIEW
C OF O_08-28-2006.TIF CERT OF OCC VIEW
None DOCUMENTS VIEW
FLOOR PLAN_11-30-2006.TIF CONSTRPLANS VIEW
6118-01-0001-01-ORIGINAL002.TIF CONSTRPLANS VIEW