Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
C of o
Type:
COMMERCIAL ALTERATION
Apply Date:
11/17/2006
Applicant:
DAVID PAPANIKOLAS
Description:
TI:AZ PARTSMASTER,
Architects:
  • GIACHETTI, RICHARD EDWARD
Contractors:
  • ALTA CONSTRUCTORS ,

Permit Reviews

Permit Number - T06CM05956
Permit Status: C of o
Permit Description: TI:AZ PARTSMASTER,
Start Date Submittal Complete Date Status  
01/22/2007 REVISION - - 1ST 01/29/2007 COMPLETED Review Details
01/29/2007 REVISION - - 1ST 01/29/2007 COMPLETED Review Details
03/01/2007 3RD PARTY REVIEW-REVISION/OTHER 03/08/2007 COMPLETED Review Details
03/22/2007 REVISION - - 1ST 03/23/2007 ACTIVE Review Details
11/20/2006 COMMERCIAL TI 11/20/2006 COMPLETED Review Details
11/20/2006 3RD PARTY REVIEW-COMMERCIAL 12/07/2006 COMPLETED Review Details
11/30/2006 RESUBMITTAL 12/06/2006 COMPLETED Review Details
12/06/2006 RESUBMITTAL 12/12/2006 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T06CM05956
Permit Status: C of o
Permit Description: TI:AZ PARTSMASTER,
Total Outstanding Activity Conditions - 1
Date Name
11/17/2006 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: C of o
Permit Number: T06CM05956
Permit Description: TI:AZ PARTSMASTER,
Total Completed Inspections - 22
Date Description Inspector Results Comments
12/15/2006 FRAMING AALEGRIA Approved IVRS - Inspection :*
PARTITIONS APPROVED 02, 04 OFFICE, NEW DOOR
COMPLETE FRAMING AND REQUEST INSPECTION
NOT MORE PARTIALS ON FRAMING.
12/21/2006 ELECTRIC - INTERMEDIATE DSANTACR Approved IVRS - Inspection :*
OK NEW WALLS PHASE ONE
12/26/2006 PLUMBING - INTERMEDIATE RRICH Approved WOMENS RESTROOM HAS FLOOR DRAIN REQUIRED
BY 2003 UPC. THAT NEEDS TO BE INSTALLED. PLAN IS APPROVED IN ERROR. MENS RESTROOM SHOWS EXISTING FLOOR DRAIN THAT DOES NOT EXIST AND IS ALSO REQUIRED BY 2003 UPC. PLAN SHOWS HOT WATER DETAIL 204 FOR LAVS AND IT APPEARS INSTA-HOT WATER HEATERS ARE TO BE INSTALLED. PLEASE HAVE REVISED APPROVED PLAN FOR THIS WORK. SHALL USE APPROVED LONG RADIUS DRAINAGE FITTING FOR URINAL DRAINAGE. INSTALL WALL CLEANOUT PER PLAN FOR LAV. TYPICAL. PLEASE TEMPORARILY PLUG ALL OPEN SEWER DRAINS IN BUILDING.
12/26/2006 PLUMBING - ROUGH, SOIL RRICH Approved IVRS - Inspection :*
CAP OF EXISTING UNDER SLAB COLUMN LINE OK
12/28/2006 SHEET ROCK NAILING AALEGRIA Approved IVRS - Inspection :*
1) NOTE: MUST PROVIDE FRAMING INSPECTION ON THE REST AREAS, DO NOT COVER DOOR SHOP FRAMING ARE NOT IN COMPLIANCE WITH APPROVED PLANS
2) VERIFY ADA RESTROOM IN COMPLIANCE WITH ANSI CODE
01/22/2007 NPPO - FINAL ACONNOR Approved
01/22/2007 LANDSCAPE - FINAL ACONNOR Approved
01/23/2007 PLUMBING - GAS PRESSURE TEST RLEDONNE Approved IVRS - Inspection :*
01/31/2007 RIGHT OF WAY - FINAL LLOPEZ Approved PER EMAIL
01/31/2007 SIGN - FINAL JYBARRA Approved IVRS - Inspection :*
03/14/2007 ELECTRIC - ABOVE CEILING DSANTACR Approved IVRS - Inspection :*
03/19/2007 ELECTRIC - FINAL DSANTACR Approved IVRS - Inspection :*
03/20/2007 MECHANICAL - FINAL JMILITEL Approved IVRS - Inspection :*
03/20/2007 MECHANICAL - ABOVE CEILING JMILITEL Approved IVRS - Inspection :*
OK FOR FINAL
03/29/2007 PLUMBING - FINAL RLEDONNE Approved IVRS - Inspection :*
03/30/2007 PLUMBING - PROGRESS RMYERS Approved
04/04/2007 ENGINEERING - FINAL MAVERY Approved
04/04/2007 BUILDING - FINAL AALEGRIA Approved IVRS - Inspection :*
04/05/2007 FIRE SPKLR - FINAL LTHOMAS Approved
04/05/2007 FIRE - FINAL LTHOMAS Approved
04/06/2007 PERMIT FINALED LJACKSON Approved
04/06/2007 BUILDING ABOVE CEILING AALEGRIA Approved

Documents

File Name Document Type  
None DOCUMENTS VIEW
None CERT OF OCC VIEW
5956-01-0001-01-REVISION2004.TIF CONSTRPLANS VIEW
5956-01-0001-01-REVISION2003.TIF CONSTRPLANS VIEW
5956-01-0001-01-REVISION2002.TIF CONSTRPLANS VIEW
5956-01-0001-01-REVISION2001.TIF CONSTRPLANS VIEW
5956-01-0001-01-REVISION003.TIF CONSTRPLANS VIEW
5956-01-0001-01-REVISION002.TIF CONSTRPLANS VIEW
5956-01-0001-01-REVISION001.TIF CONSTRPLANS VIEW
5956-01-0001-01-ORIGINAL001.TIF CONSTRPLANS VIEW
5956-01-0001-01-ORIGINAL002.TIF CONSTRPLANS VIEW
5956-01-0001-01-ORIGINAL003.TIF CONSTRPLANS VIEW
5956-01-0001-01-ORIGINAL004.TIF CONSTRPLANS VIEW
5956-01-0001-01-ORIGINAL005.TIF CONSTRPLANS VIEW
5956A-01-0001-01-ORIGINAL001.TIF CONSTRPLANS VIEW
5956A-01-0001-01-ORIGINAL002.TIF CONSTRPLANS VIEW
5956A-01-0001-01-ORIGINAL003.TIF CONSTRPLANS VIEW
5956A-01-0001-01-ORIGINAL004.TIF CONSTRPLANS VIEW
5956A-01-0001-01-ORIGINAL005.TIF CONSTRPLANS VIEW
5956A-01-0001-01-ORIGINAL006.TIF CONSTRPLANS VIEW
5956A-01-0001-01-ORIGINAL007.TIF CONSTRPLANS VIEW
5956A-01-0001-01-ORIGINAL008.TIF CONSTRPLANS VIEW
5956A-01-0001-01-ORIGINAL009.TIF CONSTRPLANS VIEW
5956A-01-0001-01-ORIGINAL010.TIF CONSTRPLANS VIEW
5956A-01-0001-01-ORIGINAL011.TIF CONSTRPLANS VIEW
5956A-01-0001-01-ORIGINAL012.TIF CONSTRPLANS VIEW
5956A-01-0001-01-ORIGINAL013.TIF CONSTRPLANS VIEW
5956A-01-0001-01-ORIGINAL014.TIF CONSTRPLANS VIEW
5956A-01-0001-01-ORIGINAL015.TIF CONSTRPLANS VIEW
5956A-01-0001-01-ORIGINAL016.TIF CONSTRPLANS VIEW
5956A-01-0001-01-ORIGINAL017.TIF CONSTRPLANS VIEW
5956A-01-0001-01-ORIGINAL018.TIF CONSTRPLANS VIEW