Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Final
Type:
SINGLE FAMILY NEW
Apply Date:
10/25/2006
Applicant:
VIZA ENTERPRISES L L C
Description:
NEW SFR TD# 16-83-60 T06-M0281 R1 Delete septic connection & show HCS R2 REVISE PUMP BASIN 8/25/08
Contractors:
  • VIZA ENTERPRISES L L C

Permit Reviews

Permit Number - T06CM05602
Permit Status: Final
Permit Description: NEW SFR TD# 16-83-60 T06-M0281 R1 Delete septic connection & show HCS R2 REVISE PUMP BASIN 8/25/08
Start Date Submittal Complete Date Status  
01/05/2007 RESIDENTIAL BLDG/WWM 01/10/2007 COMPLETED Review Details
01/10/2007 RESUBMITTAL 01/24/2007 COMPLETED Review Details
01/24/2007 RESUBMITTAL 01/30/2007 COMPLETED Review Details
01/30/2007 RESUBMITTAL 04/10/2007 COMPLETED Review Details
03/12/2008 REVISION - - 2ND 06/12/2008 COMPLETED Review Details
05/23/2007 REVISION - - 1ST 05/23/2007 COMPLETED Review Details
07/22/2008 3RD PARTY REVIEW-REVISION/OTHER 07/22/2008 COMPLETED Review Details
08/26/2008 REVISION - - 4TH 08/26/2008 COMPLETED Review Details
10/08/2008 REVISION - - 5TH 10/08/2008 COMPLETED Review Details
10/25/2006 RESIDENTIAL BLDG-MODEL PLAN/ENGINE/WALK THRU 01/05/2007 COMPLETED Review Details

Outstanding Inspections

Permit Status: Final
Permit Number: T06CM05602
Permite Description: NEW SFR TD# 16-83-60 T06-M0281 R1 Delete septic connection & show HCS R2 REVISE PUMP BASIN 8/25/08
Total Outstanding Inspections - 1
Last Inspection Date Description Inspector Results Comments
03/19/2008 ASSURANCE N/A Not ready for Inspection

Completed Inspections

Permit Status: Final
Permit Number: T06CM05602
Permit Description: NEW SFR TD# 16-83-60 T06-M0281 R1 Delete septic connection & show HCS R2 REVISE PUMP BASIN 8/25/08
Total Completed Inspections - 26
Date Description Inspector Results Comments
05/24/2007 PLUMBING - ROUGH, SOIL CRUIZ Approved IVRS - Inspection :*
1) DRAWINGS HAVE BEEN REVISED TO HCS FROM SEWER
06/11/2007 BUILDING PRE-SLAB EDURAZO Approved IVRS - Inspection :*
06/11/2007 EXCAVATION/LAYOUT REBAR & ZON EDURAZO Approved IVRS - Inspection :*
06/12/2007 ELECTRIC - UFER CRUIZ Approved IVRS - Inspection :*
07/10/2007 ROOF NAILING WNORTH Approved IVRS - Inspection :*
09/18/2007 EXT METAL CLIPS/EXT SHEATHING RCAMACHO Approved IVRS - Inspection :*
11/14/2007 U VALUE FOR WINDOW RCAMACHO Approved IVRS - Inspection :*
11/14/2007 STUCCO MESH RCAMACHO Approved IVRS - Inspection :*
11/16/2007 FRAMING RCAMACHO Approved IVRS - Inspection :
See detailed listing on site.| 999*
1) MISSING BLOCKING GARAGE SHEARWALL 1
2) MISSING 50 X 50 WINDOW PANTRY
3) FIRESTOP SOFFIT MASTER BEDROOM
4) FIRESTOP ARCH WALL GREAT ROOM WEST
5) PROVIDE WATER TEST DWV SYSTEM POTABLE WATER OK
6) EXCESSIVE CHANGE IN CAN LIGHTING THROUGHOUT-REVISE PLAN TO SHOW AS BUILTS OR BUILD TO PLAN
7) NAIL PROTECT PEX LINES MASTER GARDEN TUB
8) MISSING WALL BEDROOM ? BATH BETWEEN SHOWER AND WATER CLOSET
9) FIRE BLOCK DROPPED CEILING POWDER ROOM
10) NAIL PROTECT ABS VANITY POWDER ROOM TOP PLATE
11) DBL STUD REQUIRED AT HOLDOWN AT GARAGE CLOSET WEST WALL-RETRO FIT REQUIRED
12) OMIT REAR PORCH AT MASTER BEDROOM FROM PLAN OR BUILD TO PLAN
13) NO GAS SCHEMATIC FOUND FOR GAS LINES ON PLAN
14) STOPPED INSPECTION
11/16/2007 MECHANICAL - INTERMEDIATE RCAMACHO Approved IVRS - Inspection :
See detailed listing on site.| 999*
11/16/2007 PLUMBING - INTERMEDIATE RCAMACHO Approved IVRS - Inspection :
See detailed listing on site.| 999*
11/16/2007 ELECTRIC - INTERMEDIATE RCAMACHO Approved IVRS - Inspection :
See detailed listing on site.| 999*
03/18/2008 SHEET ROCK NAILING RCAMACHO Approved IVRS - Inspection :*
04/01/2008 ELECTRIC - CABLE DROP RCAMACHO Approved IVRS - Inspection :*
1) CANCELLED BY OWNER
04/01/2008 ELECTRIC - TEMPORARY SERVICE RCAMACHO Approved IVRS - Inspection :*
04/02/2008 TEP CLEARANCE - AM BFLORES Approved ECO PER R.CAMACHO
09/12/2008 PLUMBING - SEWER HCS CONNECT RCAMACHO Approved IVRS - Inspection :*
10/28/2008 NPPO - FINAL ACONNOR Approved
10/28/2008 LANDSCAPE - FINAL ACONNOR Approved
10/29/2008 PLUMBING - FINAL WNORTH Approved IVRS - Inspection :*
11/04/2008 PLUMBING - YARD WTR LINE/TEST RCAMACHO Approved IVRS - Inspection :*
11/04/2008 MECHANICAL - FINAL RCAMACHO Approved IVRS - Inspection :*
11/04/2008 ELECTRIC - FINAL RCAMACHO Approved IVRS - Inspection :*
11/05/2008 BUILDING - FINAL RCAMACHO Approved IVRS - Inspection :*
07/12/2013 PERMIT FINALED jgreen Approved
07/12/2013 ENGINEERING - FINAL jgreen Approved

Documents

File Name Document Type  
None DOCUMENTS VIEW
5602-01-0001-01-ORIGINAL001.TIF CONSTRPLANS VIEW
5602-01-0001-01-ORIGINAL002.TIF CONSTRPLANS VIEW
5602-01-0001-01-ORIGINAL003.TIF CONSTRPLANS VIEW
001__10.TIF CONSTRPLANS VIEW
002__9.TIF CONSTRPLANS VIEW
None CONSTRPLANS VIEW