Apply Date:
10/25/2006
Applicant:
VIZA ENTERPRISES L L C
Description:
NEW SFR TD# 16-83-60 T06-M0281 R1 Delete septic connection & show HCS R2 REVISE PUMP BASIN 8/25/08
Contractors:
- VIZA ENTERPRISES L L C
Permit Reviews
Permit Number - T06CM05602
Permit Status: Final
Permit Description: NEW SFR TD# 16-83-60 T06-M0281
R1 Delete septic connection & show HCS
R2 REVISE PUMP BASIN 8/25/08
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
01/05/2007 | RESIDENTIAL BLDG/WWM | 01/10/2007 | COMPLETED |
01/10/2007 | RESUBMITTAL | 01/24/2007 | COMPLETED |
01/24/2007 | RESUBMITTAL | 01/30/2007 | COMPLETED |
01/30/2007 | RESUBMITTAL | 04/10/2007 | COMPLETED |
03/12/2008 | REVISION - - 2ND | 06/12/2008 | COMPLETED |
05/23/2007 | REVISION - - 1ST | 05/23/2007 | COMPLETED |
07/22/2008 | 3RD PARTY REVIEW-REVISION/OTHER | 07/22/2008 | COMPLETED |
08/26/2008 | REVISION - - 4TH | 08/26/2008 | COMPLETED |
10/08/2008 | REVISION - - 5TH | 10/08/2008 | COMPLETED |
10/25/2006 | RESIDENTIAL BLDG-MODEL PLAN/ENGINE/WALK THRU | 01/05/2007 | COMPLETED |
Outstanding Inspections
Permit Status: Final
Permit Number: T06CM05602
Permite Description: NEW SFR TD# 16-83-60 T06-M0281
R1 Delete septic connection & show HCS
R2 REVISE PUMP BASIN 8/25/08
Total Outstanding Inspections - 1
Last Inspection Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/19/2008 | ASSURANCE | N/A | Not ready for Inspection |
Completed Inspections
Permit Status: Final
Permit Number: T06CM05602
Permit Description: NEW SFR TD# 16-83-60 T06-M0281
R1 Delete septic connection & show HCS
R2 REVISE PUMP BASIN 8/25/08
Total Completed Inspections - 26
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/24/2007 | PLUMBING - ROUGH, SOIL | CRUIZ | Approved | IVRS - Inspection :* 1) DRAWINGS HAVE BEEN REVISED TO HCS FROM SEWER |
06/11/2007 | BUILDING PRE-SLAB | EDURAZO | Approved | IVRS - Inspection :* |
06/11/2007 | EXCAVATION/LAYOUT REBAR & ZON | EDURAZO | Approved | IVRS - Inspection :* |
06/12/2007 | ELECTRIC - UFER | CRUIZ | Approved | IVRS - Inspection :* |
07/10/2007 | ROOF NAILING | WNORTH | Approved | IVRS - Inspection :* |
09/18/2007 | EXT METAL CLIPS/EXT SHEATHING | RCAMACHO | Approved | IVRS - Inspection :* |
11/14/2007 | U VALUE FOR WINDOW | RCAMACHO | Approved | IVRS - Inspection :* |
11/14/2007 | STUCCO MESH | RCAMACHO | Approved | IVRS - Inspection :* |
11/16/2007 | FRAMING | RCAMACHO | Approved | IVRS - Inspection : See detailed listing on site.| 999* 1) MISSING BLOCKING GARAGE SHEARWALL 1 2) MISSING 50 X 50 WINDOW PANTRY 3) FIRESTOP SOFFIT MASTER BEDROOM 4) FIRESTOP ARCH WALL GREAT ROOM WEST 5) PROVIDE WATER TEST DWV SYSTEM POTABLE WATER OK 6) EXCESSIVE CHANGE IN CAN LIGHTING THROUGHOUT-REVISE PLAN TO SHOW AS BUILTS OR BUILD TO PLAN 7) NAIL PROTECT PEX LINES MASTER GARDEN TUB 8) MISSING WALL BEDROOM ? BATH BETWEEN SHOWER AND WATER CLOSET 9) FIRE BLOCK DROPPED CEILING POWDER ROOM 10) NAIL PROTECT ABS VANITY POWDER ROOM TOP PLATE 11) DBL STUD REQUIRED AT HOLDOWN AT GARAGE CLOSET WEST WALL-RETRO FIT REQUIRED 12) OMIT REAR PORCH AT MASTER BEDROOM FROM PLAN OR BUILD TO PLAN 13) NO GAS SCHEMATIC FOUND FOR GAS LINES ON PLAN 14) STOPPED INSPECTION |
11/16/2007 | MECHANICAL - INTERMEDIATE | RCAMACHO | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
11/16/2007 | PLUMBING - INTERMEDIATE | RCAMACHO | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
11/16/2007 | ELECTRIC - INTERMEDIATE | RCAMACHO | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
03/18/2008 | SHEET ROCK NAILING | RCAMACHO | Approved | IVRS - Inspection :* |
04/01/2008 | ELECTRIC - CABLE DROP | RCAMACHO | Approved | IVRS - Inspection :* 1) CANCELLED BY OWNER |
04/01/2008 | ELECTRIC - TEMPORARY SERVICE | RCAMACHO | Approved | IVRS - Inspection :* |
04/02/2008 | TEP CLEARANCE - AM | BFLORES | Approved | ECO PER R.CAMACHO |
09/12/2008 | PLUMBING - SEWER HCS CONNECT | RCAMACHO | Approved | IVRS - Inspection :* |
10/28/2008 | NPPO - FINAL | ACONNOR | Approved | |
10/28/2008 | LANDSCAPE - FINAL | ACONNOR | Approved | |
10/29/2008 | PLUMBING - FINAL | WNORTH | Approved | IVRS - Inspection :* |
11/04/2008 | PLUMBING - YARD WTR LINE/TEST | RCAMACHO | Approved | IVRS - Inspection :* |
11/04/2008 | MECHANICAL - FINAL | RCAMACHO | Approved | IVRS - Inspection :* |
11/04/2008 | ELECTRIC - FINAL | RCAMACHO | Approved | IVRS - Inspection :* |
11/05/2008 | BUILDING - FINAL | RCAMACHO | Approved | IVRS - Inspection :* |
07/12/2013 | PERMIT FINALED | jgreen | Approved | |
07/12/2013 | ENGINEERING - FINAL | jgreen | Approved |