Permit: T06CM05602

Parcel: 116300530

Inspection Status: Approved

Inspection History: BUILDING - FINAL

Permit Number - T06CM05602

Inspection Description - BUILDING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
11/05/2008 BUILDING - FINAL Approved IVRS - Inspection :*
11/04/2008 BUILDING - FINAL Partial Approval IVRS - Inspection :*
1) PENDING CERTS
10/31/2008 BUILDING - FINAL Not ready for Inspection IVRS - Inspection :*
1) CANCELLED PER ALEX
10/30/2008 BUILDING - FINAL Not ready for Inspection IVRS - Inspection :*
1) CANCELLED PER ALEX
10/29/2008 BUILDING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NEED SECONDARY CUT OFF SWITCH ON FURNACES
2) OPEN GROUND DEN RECEPTACLES
3) POST STREET ADDRESS
4) A/C MAX FUSE 40 AMPS. FILL HOLE IN DISCONNECT. EAST UNIT
5) MARK FURNACE LABEL FOR HEAT STRIP
6) INSTALL FUSES WATER HEATER
7) A/C MAX FUSE 50 AMPS NORTH UNIT
8) CHANGE NORTH SIDE A/C BREAKER TO 50 AMPS USE ONLY CUTLER HAMMER BREAKERS.
9) ONLY THE TWO RECEPTACLES ON OUTSIDE OF GARAGE TEST GFI
10) OTHERS OUTSIDE DON'T TEST. KITCHEN RECEPT S.E. CORNER DOESN'T TEST GFI