Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T06CM05602
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/14/2008 | FRAMING | Approved | IVRS - Inspection :* | |
02/13/2008 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NO GATE CODE LEFT |
|
01/11/2008 | FRAMING | Partial Approval | IVRS - Inspection :* 1) OK TO INSULATE 2) NEED ELECTRIC TO FURNACES 3) ADD RECEPT S.W. BATHROOM LAV 4) NEED ELECTRIC TO NORTH WATER HEATER 5) NEED DUCT FOR KITCHEN EXHAUST 6) NEED LINE SETS FOR A/C UNITS |
|
11/16/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) MISSING BLOCKING GARAGE SHEARWALL 1 2) MISSING 50 X 50 WINDOW PANTRY 3) FIRESTOP SOFFIT MASTER BEDROOM 4) FIRESTOP ARCH WALL GREAT ROOM WEST 5) PROVIDE WATER TEST DWV SYSTEM POTABLE WATER OK 6) EXCESSIVE CHANGE IN CAN LIGHTING THROUGHOUT-REVISE PLAN TO SHOW AS BUILTS OR BUILD TO PLAN 7) NAIL PROTECT PEX LINES MASTER GARDEN TUB 8) MISSING WALL BEDROOM ? BATH BETWEEN SHOWER AND WATER CLOSET 9) FIRE BLOCK DROPPED CEILING POWDER ROOM 10) NAIL PROTECT ABS VANITY POWDER ROOM TOP PLATE 11) DBL STUD REQUIRED AT HOLDOWN AT GARAGE CLOSET WEST WALL-RETRO FIT REQUIRED 12) OMIT REAR PORCH AT MASTER BEDROOM FROM PLAN OR BUILD TO PLAN 13) NO GAS SCHEMATIC FOUND FOR GAS LINES ON PLAN 14) STOPPED INSPECTION |
|
11/14/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PROVIDE LEGIBLE COMPLETE SET OF PLANS |
|
11/13/2007 | FRAMING | Not ready for Inspection | IVRS - Inspection :* 1) CANCELLED PER OWNER EDMUNDO |
|
11/09/2007 | FRAMING | Not ready for Inspection | IVRS - Inspection :* | |
07/10/2007 | FRAMING | Not ready for Inspection | IVRS - Inspection :* |