Permit Details

Status:
C of o
Type:
COMMERCIAL ALTERATION
Address:
1050 E NAVAJO RD
Address NEW:
1050 E NAVAJO RD
Apply Date:
10/04/2006
Applicant:
METRO PERMIT EXPRESS, INC *C
Description:
TI: REHAB HOUSE
Contractors:
  • CAYLOR CONSTRUCTION COMPANY , RO

Permit Reviews

Permit Number - T06CM05266
Permit Status: C of o
Permit Description: TI: REHAB HOUSE
Start Date Submittal Complete Date Status  
10/04/2006 PLANS OK TO SUBMIT - 3RD PARTY 10/13/2006 COMPLETED Review Details
10/13/2006 3RD PARTY REVIEW-COMMERCIAL TI 10/27/2006 COMPLETED Review Details
10/27/2006 POST 3RD PARTY REVIEW 11/16/2006 COMPLETED Review Details
11/16/2006 RESUBMITTAL 01/02/2007 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T06CM05266
Permit Status: C of o
Permit Description: TI: REHAB HOUSE
Total Outstanding Activity Conditions - 1
Date Name
10/04/2006 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: C of o
Permit Number: T06CM05266
Permit Description: TI: REHAB HOUSE
Total Completed Inspections - 25
Date Description Inspector Results Comments
11/21/2006 MECHANICAL - ABOVE CEILING JMILITEL Approved IVRS - Inspection :*
11/21/2006 MECHANICAL - INTERMEDIATE JMILITEL Approved IVRS - Inspection :*
OK FOR SHEETROCK
11/27/2006 BUILDING ABOVE CEILING GDABBS Approved IVRS - Inspection :*
11/27/2006 FRAMING GDABBS Approved IVRS - Inspection :*
11/27/2006 ROOF NAILING GDABBS Approved IVRS - Inspection :*
11/29/2006 PLUMBING - INTERMEDIATE RMYERS Approved IVRS - Inspection :*
OK TO COVER ALL AREAS
12/04/2006 BUILDING - FINAL LHANLY Approved IVRS - Inspection :*
BEFORE FINAL YOU NEED
1. TO ADD CURB RAIL FOR RAMP PER ANSI A117.1
2. IF ACCESSIBLE UNIT THEN REMOVE THRESHOLD AT ENTRY IF ACCESS ADAPTABLE YOU MAY LEAVE THRESHOLD.
12/04/2006 SHEET ROCK NAILING LHANLY Approved IVRS - Inspection :*
12/08/2006 RIGHT OF WAY - FINAL MOTERO Approved PER EMAIL
12/08/2006 ELECTRIC - INTERMEDIATE CCLEMENS Approved IVRS - Inspection :*
CALL WHEN READY FOR FINAL
12/08/2006 FIRE - FINAL SHIGGINB Approved
12/08/2006 ELECTRIC - ABOVE CEILING CCLEMENS Approved IVRS - Inspection :*
12/08/2006 NPPO - FINAL ACONNOR Approved
12/08/2006 LANDSCAPE - FINAL ACONNOR Approved
12/08/2006 SIGN - FINAL JYBARRA Approved IVRS - Inspection :*
01/02/2007 MECHANICAL - FINAL JMILITEL Approved IVRS - Inspection :*
01/02/2007 ELECTRIC - SERVICE UPGRADE CCLEMENS Approved
01/02/2007 ELECTRIC - FINAL CCLEMENS Approved IVRS - Inspection :
The wiring is not complete or does not comply with code.| 245*
1. TIGHTEN ALL LOOSE DEVICES - NEC 406.4
2. LIGHT FIXTURES IN CLOSETS NEED 12" CLEARANCE TO SHELF -- NEC 410.8
3. PROVIDE ARC FAULT PROTECTION FOR SMOKE DETECTORS
NEC 210.12
4. RECEPTACLE FACES TO BE FLUSH WITH COVER PLATE, NO TWISTED OR SETBACK - NEC 406.4D
5. NEED SWITCHED LIGHT OR RECEPTACLE IN LIVING ROOM
NEC 210.70
6. AT WATER HEATER:
A. PROVIDE PROPER DISCONNECTING MEANS - NEC 422.31
(NOT TOGGLE SWITCH)
B. SCREW J-BOX COVER PLATE TO BOX
C. STRAP MC WITHIN 12" OF TERMINATIONS - NEC 330.30
D. IDENTIFY WHITE USED AS HOT - NEC 200.6
7. USE CONNECTOR FOR ROMEX ENTERING HOOD - NEC 334
8. INSTALL DISPOSAL WIRING & COVER FOR ITS RECEPTACLE
9. EAST PORCH LIGHT NOT WORKING
10. AT SERVICE
A. PANEL DIRECTORY NEEDS TO BE CORRECTLY IDENTIFIED IN A CLEAR, PERMANENT, AND LEGIBLE MANNER - NEC 408.4
B. EXPOSE GROUND RODS - NEC 250.53G
C. BOND GAS PIPE - NEC 250.104
D. BURY GROUNDING ELECTRODE CONDUCTOR MINIMUM 12" OR SECURE TO STRUCTURE - NEC 300.5, 250.64
E. MAXIMUM 15 AMPS ON 14GA CONDUCTOR - NEC 310.15
11. PROVIDE SERVICE RECEPTACLE FOR ROOFTOP UNIT --
NEC 210.63
01/02/2007 ELECTRIC - FINAL CCLEMENS Approved IVRS - Inspection :*
01/02/2007 OUTDOOR LIGHTING FINAL CCLEMENS Approved IVRS - Inspection :*
01/02/2007 ELECTRIC - SERVICE UPGRADE CCLEMENS Approved IVRS - Inspection :*
01/02/2007 ENGINEERING - FINAL JBRUCKME Approved
01/12/2007 PLUMBING - FINAL LHANLY Approved
01/12/2007 PLUMBING - FINAL BBENEDON Approved IVRS - Inspection :
See detailed listing on site.| 999*
1. MISSING HB VACUUM BREAKERS
2. T&P SHALL TERMINATE 6"-24" ABOVE GRADE

BACTERIA REPORT RECOVERED
OTHER CORRECTIONS OK
01/16/2007 PERMIT FINALED LJACKSON Approved

Documents

File Name Document Type  
None DOCUMENTS VIEW
C OF O_01-16-2007.TIF CERT OF OCC VIEW