Permit: T06CM05266
Permit Details
Apply Date:
10/04/2006
Applicant:
METRO PERMIT EXPRESS, INC *C
Description:
TI: REHAB HOUSE
Contractors:
- CAYLOR CONSTRUCTION COMPANY , RO
Permit Reviews
Permit Number - T06CM05266
Permit Status: C of o
Permit Description: TI: REHAB HOUSE
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 10/04/2006 | PLANS OK TO SUBMIT - 3RD PARTY | 10/13/2006 | COMPLETED |
| 10/13/2006 | 3RD PARTY REVIEW-COMMERCIAL TI | 10/27/2006 | COMPLETED |
| 10/27/2006 | POST 3RD PARTY REVIEW | 11/16/2006 | COMPLETED |
| 11/16/2006 | RESUBMITTAL | 01/02/2007 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T06CM05266
Permit Status: C of o
Permit Description: TI: REHAB HOUSE
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 10/04/2006 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T06CM05266
Permit Description: TI: REHAB HOUSE
Total Completed Inspections - 25
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/21/2006 | MECHANICAL - ABOVE CEILING | JMILITEL | Approved | IVRS - Inspection :* |
| 11/21/2006 | MECHANICAL - INTERMEDIATE | JMILITEL | Approved | IVRS - Inspection :* OK FOR SHEETROCK |
| 11/27/2006 | BUILDING ABOVE CEILING | GDABBS | Approved | IVRS - Inspection :* |
| 11/27/2006 | FRAMING | GDABBS | Approved | IVRS - Inspection :* |
| 11/27/2006 | ROOF NAILING | GDABBS | Approved | IVRS - Inspection :* |
| 11/29/2006 | PLUMBING - INTERMEDIATE | RMYERS | Approved | IVRS - Inspection :* OK TO COVER ALL AREAS |
| 12/04/2006 | BUILDING - FINAL | LHANLY | Approved | IVRS - Inspection :* BEFORE FINAL YOU NEED 1. TO ADD CURB RAIL FOR RAMP PER ANSI A117.1 2. IF ACCESSIBLE UNIT THEN REMOVE THRESHOLD AT ENTRY IF ACCESS ADAPTABLE YOU MAY LEAVE THRESHOLD. |
| 12/04/2006 | SHEET ROCK NAILING | LHANLY | Approved | IVRS - Inspection :* |
| 12/08/2006 | RIGHT OF WAY - FINAL | MOTERO | Approved | PER EMAIL |
| 12/08/2006 | ELECTRIC - INTERMEDIATE | CCLEMENS | Approved | IVRS - Inspection :* CALL WHEN READY FOR FINAL |
| 12/08/2006 | FIRE - FINAL | SHIGGINB | Approved | |
| 12/08/2006 | ELECTRIC - ABOVE CEILING | CCLEMENS | Approved | IVRS - Inspection :* |
| 12/08/2006 | NPPO - FINAL | ACONNOR | Approved | |
| 12/08/2006 | LANDSCAPE - FINAL | ACONNOR | Approved | |
| 12/08/2006 | SIGN - FINAL | JYBARRA | Approved | IVRS - Inspection :* |
| 01/02/2007 | MECHANICAL - FINAL | JMILITEL | Approved | IVRS - Inspection :* |
| 01/02/2007 | ELECTRIC - SERVICE UPGRADE | CCLEMENS | Approved | |
| 01/02/2007 | ELECTRIC - FINAL | CCLEMENS | Approved | IVRS - Inspection : The wiring is not complete or does not comply with code.| 245* 1. TIGHTEN ALL LOOSE DEVICES - NEC 406.4 2. LIGHT FIXTURES IN CLOSETS NEED 12" CLEARANCE TO SHELF -- NEC 410.8 3. PROVIDE ARC FAULT PROTECTION FOR SMOKE DETECTORS NEC 210.12 4. RECEPTACLE FACES TO BE FLUSH WITH COVER PLATE, NO TWISTED OR SETBACK - NEC 406.4D 5. NEED SWITCHED LIGHT OR RECEPTACLE IN LIVING ROOM NEC 210.70 6. AT WATER HEATER: A. PROVIDE PROPER DISCONNECTING MEANS - NEC 422.31 (NOT TOGGLE SWITCH) B. SCREW J-BOX COVER PLATE TO BOX C. STRAP MC WITHIN 12" OF TERMINATIONS - NEC 330.30 D. IDENTIFY WHITE USED AS HOT - NEC 200.6 7. USE CONNECTOR FOR ROMEX ENTERING HOOD - NEC 334 8. INSTALL DISPOSAL WIRING & COVER FOR ITS RECEPTACLE 9. EAST PORCH LIGHT NOT WORKING 10. AT SERVICE A. PANEL DIRECTORY NEEDS TO BE CORRECTLY IDENTIFIED IN A CLEAR, PERMANENT, AND LEGIBLE MANNER - NEC 408.4 B. EXPOSE GROUND RODS - NEC 250.53G C. BOND GAS PIPE - NEC 250.104 D. BURY GROUNDING ELECTRODE CONDUCTOR MINIMUM 12" OR SECURE TO STRUCTURE - NEC 300.5, 250.64 E. MAXIMUM 15 AMPS ON 14GA CONDUCTOR - NEC 310.15 11. PROVIDE SERVICE RECEPTACLE FOR ROOFTOP UNIT -- NEC 210.63 |
| 01/02/2007 | ELECTRIC - FINAL | CCLEMENS | Approved | IVRS - Inspection :* |
| 01/02/2007 | OUTDOOR LIGHTING FINAL | CCLEMENS | Approved | IVRS - Inspection :* |
| 01/02/2007 | ELECTRIC - SERVICE UPGRADE | CCLEMENS | Approved | IVRS - Inspection :* |
| 01/02/2007 | ENGINEERING - FINAL | JBRUCKME | Approved | |
| 01/12/2007 | PLUMBING - FINAL | LHANLY | Approved | |
| 01/12/2007 | PLUMBING - FINAL | BBENEDON | Approved | IVRS - Inspection : See detailed listing on site.| 999* 1. MISSING HB VACUUM BREAKERS 2. T&P SHALL TERMINATE 6"-24" ABOVE GRADE BACTERIA REPORT RECOVERED OTHER CORRECTIONS OK |
| 01/16/2007 | PERMIT FINALED | LJACKSON | Approved |