Permit: T06CM04571
Permit Details
Apply Date:
08/14/2006
Applicant:
METRO PERMIT EXPRESS, INC *C
Description:
TI: RESTAURANT
Contractors:
- HIDDEN HOLLOW CONSTRUCTION
Permit Reviews
Permit Number - T06CM04571
Permit Status: C of o
Permit Description: TI: RESTAURANT
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
01/23/2007 | 3RD PARTY REVIEW-REVISION/OTHER | 02/01/2007 | COMPLETED |
04/23/2007 | REVISION - - 1ST | 04/24/2007 | COMPLETED |
08/14/2006 | PLANS OK TO SUBMIT - COMM | 08/15/2006 | COMPLETED |
08/15/2006 | 3RD PARTY REVIEW-COMMERCIAL TI | 09/15/2006 | COMPLETED |
09/15/2006 | POST 3RD PARTY REVIEW | 09/28/2006 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T06CM04571
Permit Status: C of o
Permit Description: TI: RESTAURANT
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
08/14/2006 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T06CM04571
Permit Description: TI: RESTAURANT
Total Completed Inspections - 43
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/14/2006 | MECHANICAL - INTERMEDIATE | JMILITEL | Approved | IVRS - Inspection :* 1. SUSPENDED ROUGH DUCT, FAN COILS, CONDENSATE LINES OK TO PROCEED. 2. PROVIDE BUSHINGS IN FAN COIL CABINET AT REFER LINE CONNECTION. 3. PROVIDE DRAIN PANS UNDER FAN COILS. |
12/14/2006 | FRAMING | GDABBS | Approved | IVRS - Inspection :* |
12/22/2006 | PLUMBING - ROUGH, SOIL | RMYERS | Approved | IVRS - Inspection :* ABS DWV THRU ROOF OK WATER TEST OK CLOSET FLANGES OK |
12/22/2006 | PLUMBING - BACK WATER VALVE | RMYERS | Approved | IVRS - Inspection :* |
12/22/2006 | PLUMBING - PRE SLAB | RMYERS | Approved | IVRS - Inspection :* |
01/12/2007 | PLUMBING - GAS PRESSURE TEST | BBENEDON | Approved | IVRS - Inspection :* |
01/12/2007 | PLUMBING - INTERMEDIATE | BBENEDON | Approved | IVRS - Inspection :* |
02/02/2007 | BUILDING ABOVE CEILING | AALEGRIA | Approved | IVRS - Inspection :* |
02/06/2007 | SHEET ROCK NAILING | AQUIROZ | Approved | IVRS - Inspection :* |
02/09/2007 | MECHANICAL - HOODS | JMILITEL | Approved | IVRS - Inspection :* FANS, GREASE DUCTS, CLEANOUTS, FIRE WRAP OK STILL NEED TO SEE ACCESS DOORS 2ND FLOOR CHECKED FAN COILS OK FOR CEILING TILES. |
02/15/2007 | ELECTRIC - ABOVE CEILING | RMAJUTA | Approved | IVRS - Inspection :* 1ST & BASEMENT |
02/20/2007 | PLUMBING - GAS PRESS TEST FNL | RLEDONNE | Approved | IVRS - Inspection :* |
02/20/2007 | PLUMBING - GAS RECONNECT | RLEDONNE | Approved | IVRS - Inspection :* |
02/26/2007 | ELECTRIC - INTERMEDIATE | RMAJUTA | Approved | IVRS - Inspection :* |
04/10/2007 | RIGHT OF WAY - FINAL | MOTERO | Approved | |
04/10/2007 | RIGHT OF WAY - FINAL | MOTERO | Approved | PER EMAIL |
04/10/2007 | ENGINEERING - FINAL | MRUSSO | Approved | |
04/10/2007 | SIGN - FINAL | JYBARRA | Approved | IVRS - Inspection :* |
04/10/2007 | NPPO - FINAL | ACONNOR | Approved | N/A |
04/10/2007 | LANDSCAPE - FINAL | ACONNOR | Approved | N/A |
04/20/2007 | ELECTRIC - OUTDOOR LIGHTING | DSANTACR | Approved | |
04/20/2007 | ELECTRIC - FINAL | DSANTACR | Approved | IVRS - Inspection :* |
04/23/2007 | OUTDOOR LIGHTING FINAL | DSANTACR | Approved | |
04/23/2007 | ELECTRIC - TEMPORARY SERVICE | DSANTACR | Approved | |
04/23/2007 | ELECTRIC - CONSTRUCTION POWER | DSANTACR | Approved | |
04/23/2007 | ELECTRIC - TEMP POWER FOR TEST | DSANTACR | Approved | |
04/23/2007 | ELECTRIC - SERVICE UPGRADE | DSANTACR | Approved | |
04/23/2007 | ELECTRIC - RECONNECT | DSANTACR | Approved | |
04/23/2007 | ELECTRIC - PROGRESS | DSANTACR | Approved | |
04/24/2007 | HEALTH DEPT - FINAL 724-7908 | MVANDERE | Approved | |
04/24/2007 | PLUMBING - FINAL | RMYERS | Approved | IVRS - Inspection :* 1. PLEASE PROVIDE THE LISTING FOR THE ICE MAKER THAT STATES THAT IT HAS AN INTERNAL AIR GAP AND/OR HAS BEEN TESTED UNDER ACTUAL BACKFLOW CONDITIONS. 2. BOB RICH & I VISUALLY DETERMINED A ONE INCH AIR GAP IN LIEU OF A LISTING 3. OK FOR C OF O S.T.O.I |
04/24/2007 | PLUMBING - PROGRESS | RMYERS | Approved | IVRS - Inspection :* |
04/24/2007 | FIRE - KITCHEN EXH HOOD FINAL | LLAKEY | Approved | |
04/24/2007 | FIRE - FINAL | LLAKEY | Approved | PER PLAN RECHECK PANIC HARDWARE NOT REQUIRED |
04/25/2007 | MECHANICAL - FINAL | JMILITEL | Approved | AIR BALANCE REPORT OK OK FOR FINAL |
04/25/2007 | MECHANICAL - PROGRESS | JMILITEL | Approved | |
04/25/2007 | MECHANICAL - HOOD SYSTEMS | JMILITEL | Approved | |
04/27/2007 | BUILDING - FINAL | AALEGRIA | Approved | IVRS - Inspection :* BUILDING FINAL IN COMPLIANCE WITH APPROVED PLAN AND SPECIFICATIONS ALSO, IN COMPLIANCE WITH SECTION 109.3.10 OK TO FILE FOR CERTIFICATE OF OCCUPANCY. |
04/27/2007 | FIRE SPKLR - FINAL | LLAKEY | Approved | |
04/30/2007 | U VALUE FOR WINDOW | AALEGRIA | Approved | |
04/30/2007 | BUILDING - PROGRESS | AALEGRIA | Approved | |
04/30/2007 | EXCAVATION/LAYOUT REBAR & ZON | AALEGRIA | Approved | |
04/30/2007 | BUILDING PRE-SLAB | AALEGRIA | Approved |