Permit Reviews

Permit Number - T06CM03833
Permit Status: C of o
Permit Description: SFR:TD#16-51-41 T05-M0271
Start Date Submittal Complete Date Status  
06/29/2006 RESIDENTIAL BLDG-MODEL PLAN/ENGINE/WALK THRU 06/29/2006 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T06CM03833
Permit Status: C of o
Permit Description: SFR:TD#16-51-41 T05-M0271
Total Outstanding Activity Conditions - 1
Date Name
06/29/2006 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: C of o
Permit Number: T06CM03833
Permit Description: SFR:TD#16-51-41 T05-M0271
Total Completed Inspections - 26
Date Description Inspector Results Comments
08/04/2006 ELECTRIC - UFER JRIVA Approved IVRS - Inspection :*
08/04/2006 BUILDING PRE-SLAB JRIVA Approved IVRS - Inspection :*
08/04/2006 EXCAVATION/LAYOUT REBAR & ZON JRIVA Approved IVRS - Inspection :*
08/04/2006 PLUMBING - SEWER HCS CONNECT JRIVA Approved IVRS - Inspection :*
08/04/2006 PLUMBING - YARD WTR LINE/TEST JRIVA Approved IVRS - Inspection :*
08/04/2006 PLUMBING - ROUGH, SOIL JRIVA Approved IVRS - Inspection :*
10/11/2006 ROOF NAILING CRUIZ Approved IVRS - Inspection :*
11/01/2006 EXT METAL CLIPS/EXT SHEATHING JRIVA Approved IVRS - Inspection :*
1) ITEMS 4 AND 6 NOT DONE
2) HAVE PLAN CHANGES APPROVED BY CITY OF TUCSON
3) HOUSE OK TO DRY IN
11/27/2006 U VALUE FOR WINDOW CTREVILL Approved IVRS - Inspection :
See detailed listing on site.| 999*
11/30/2006 FRAMING JRIVA Approved IVRS - Inspection :
See detailed listing on site.| 999*
1) LATHE NOT COMPLETE FRONT OVER PATIO
2) SEAL ALL LATHE PENETRATIONS
3) FLOOR TRUSS IN GARAGE TOP CHORD CUT BY PLUMBING. PROVIDE CITY OF TUCSON APPROVED TRUSS REPAIR DOCUMENT
4) PLAN CALLS FOR FLOR TRUSSES AT 16" ON CENTER INSTALLED AT 24" ON CENTER. BUILD TO PLAN OR REVERSE PLAN TO AS BUILT
5) 4 X 12 BEAM CARRING FLOOR TRUSSES IS NOT ON PLAN. REVISE PLAN. WHAT IS IT TO BEAR ON ?
6) STAIR HEADER TRUSS CUT. PROVIDE CITY OF TUCSON APPROVED ENGINGEERING REPAIR
7) PROVIDE APPROVED TRUSS DRAWINGS
8) STAIRS EXCEED 7 3/4" RISE
9) STOPPED INSPECTION-TOO MANY ITEMS
11/30/2006 PLUMBING - GAS PRESSURE TEST JRIVA Approved IVRS - Inspection :
See detailed listing on site.| 999*
11/30/2006 MECHANICAL - INTERMEDIATE JRIVA Approved IVRS - Inspection :
See detailed listing on site.| 999*
11/30/2006 PLUMBING - INTERMEDIATE JRIVA Approved IVRS - Inspection :
See detailed listing on site.| 999*
11/30/2006 ELECTRIC - INTERMEDIATE JRIVA Approved IVRS - Inspection :
See detailed listing on site.| 999*
11/30/2006 STUCCO MESH JRIVA Approved IVRS - Inspection :
See detailed listing on site.| 999*
02/20/2007 SHEET ROCK NAILING EDURAZO Approved IVRS - Inspection :*
04/05/2007 ELECTRIC - TEMPORARY SERVICE JRIVA Approved IVRS - Inspection :*
04/05/2007 ELECTRIC - CABLE DROP JRIVA Approved IVRS - Inspection :*
05/16/2007 TEP CLEARANCE - AM JWEATHER Approved ECO CLEARED PER J. RIVA
11/06/2007 BUILDING - FINAL JRIVA Approved IVRS - Inspection :
Work is not complete enough to inspect.| 950*
1) SECURE A/C CONDENSOR FLEX CONDUIT WITHIN 12" OF DISCONNECT
2) PROVIDE POST TENSION TAG AT WATER SHUT OFF VALVE
3) REPAIR DAMAGED WIRE AND LABEL IRRIGATION CIRCUIT
4) IMPROPER COLOR CODE OF A/C WIRES WHITE CANNOT BE HOT
5) NO REAR PORCH LIGHT OR BALCONY LIGHT
6) BALCONY DRAIN CANNOT HAVE OPENING GREATER THAN 4"
7) PROVIDE 1/4" PER FOOT PITCH ON A/C DRAIN PAN
8) SECURE FURNACE WHIP WITHIN 12" OF DISCONNECT
9) WIRE COLOR CODE WRONG
10) SECURE WIRE WITHIN 8" OF DISCONNECT
11) MARK FAU HEAT STRIP LABEL
12) STOPPED INSPECTION-TO MANY ITEMS
13) NO PLAN ON SITE
11/06/2007 MECHANICAL - FINAL JRIVA Approved IVRS - Inspection :
Work is not complete enough to inspect.| 950*
11/06/2007 PLUMBING - FINAL JRIVA Approved IVRS - Inspection :
Work is not complete enough to inspect.| 950*
11/06/2007 ELECTRIC - FINAL JRIVA Approved IVRS - Inspection :
Work is not complete enough to inspect.| 950*
03/18/2010 PLUMBING - GAS PRESS TEST FNL RFREIDIN Approved
03/18/2010 OUTDOOR LIGHTING FINAL RFREIDIN Approved
03/18/2010 ELECTRIC - OUTDOOR LIGHTING RFREIDIN Approved