| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 06/12/2006 | RESIDENTIAL BLDG-MODEL PLAN/ENGINE/WALK THRU | 06/14/2006 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T06CM03460
Permit Status: C of o
Permit Description: SFR TD # 16-63-57 T06-M0056
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 06/12/2006 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T06CM03460
Permit Description: SFR TD # 16-63-57 T06-M0056
Total Completed Inspections - 23
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/24/2006 | ELECTRIC - UFER | CRUIZ | Approved | IVRS - Inspection :* |
| 08/24/2006 | BUILDING PRE-SLAB | CRUIZ | Approved | IVRS - Inspection :* |
| 08/24/2006 | EXCAVATION/LAYOUT REBAR & ZON | CRUIZ | Approved | IVRS - Inspection :* |
| 12/12/2006 | PLUMBING - ROUGH, SOIL | CRUIZ | Approved | |
| 12/12/2006 | PLUMBING - YARD WTR LINE/TEST | CRUIZ | Approved | NEED ANTI-SIPHON AT HOSE BIB OK TO BACKFILL |
| 12/12/2006 | PLUMBING - SEWER HCS CONNECT | CRUIZ | Approved | IVRS - Inspection :* |
| 12/26/2006 | EXT METAL CLIPS/EXT SHEATHING | RFREIDIN | Approved | IVRS - Inspection : See detailed listing on site.| 999* 1) MISSING WIND BRACING 2ND FLOOR 2) STHD-10 NORTH WALL TO BE IN LINE WITH SHEARWALL RUNNING N. & SOUTH 3) REAR WALL MISSING (D) P.A.'S 4) KITCHEN WINDOW CRIPPLES NOT PLUMB 5) NORTH WALL AT MISSING STHD-10 STRAPM POST TO BEAM SEE 18/D3 6) NAIL BOTTOM PLATE SHEARWALL AT/STAIR 2ND FLOOR 7) MISSING HANGERS ROOF USE CORRECT TYPE 8) DBL TOP PLATE SPLICES TO BE STAGGERED OR USE LARGE FHA STRAPS NORTH WALL 9) WINDOW NORTH WALL ADD CRIPPLES, SHIM HEADER 10) MORE NAILS IN HANGER STAIR, HEADER 11) FROM GIRDER ROOF BLOCK BETWEEN FLOORS UNDER DBL STUDS 12) STRAPS ACROSS FRONT WINDOW NAILS MISSED BLOCKS 13) LOOSE B/PLATE FRONT DOOR 14) MISSING NAILING ON ROOF, MARKED ON FLOOR BELOW, NAIL ALL FRIEZE BLOCKS 15) ?/D6 BLOCKS MISSING 16) FULL LENGTH STUDS LTT20 AT INT. STAIR SHEAR, FINISH H.D.'S STRAP ABOVE |
| 12/26/2006 | ROOF NAILING | RFREIDIN | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
| 01/18/2007 | PLUMBING - GAS PRESSURE TEST | WNORTH | Approved | IVRS - Inspection :* |
| 01/18/2007 | ELECTRIC - INTERMEDIATE | WNORTH | Approved | IVRS - Inspection :* |
| 01/18/2007 | STUCCO MESH | WNORTH | Approved | IVRS - Inspection :* |
| 01/29/2007 | MECHANICAL - INTERMEDIATE | CTREVILL | Approved | IVRS - Inspection :* |
| 01/29/2007 | PLUMBING - INTERMEDIATE | CTREVILL | Approved | IVRS - Inspection :* |
| 01/29/2007 | FRAMING | CTREVILL | Approved | IVRS - Inspection :* |
| 02/06/2007 | SHEET ROCK NAILING | CRUIZ | Approved | IVRS - Inspection :* |
| 02/12/2007 | ELECTRIC - TEMPORARY SERVICE | WLAHR | Approved | IVRS - Inspection :* |
| 02/12/2007 | ELECTRIC - CABLE DROP | WLAHR | Approved | IVRS - Inspection :* |
| 02/13/2007 | TEP CLEARANCE - AM | JWEATHER | Approved | ECO CLEARED PER W. LAHR |
| 03/30/2007 | MECHANICAL - FINAL | WNORTH | Approved | IVRS - Inspection :* |
| 03/30/2007 | PLUMBING - FINAL | WNORTH | Approved | IVRS - Inspection :* |
| 03/30/2007 | ELECTRIC - FINAL | WNORTH | Approved | IVRS - Inspection :* |
| 03/30/2007 | BUILDING - FINAL | WNORTH | Approved | IVRS - Inspection :* |
| 04/24/2007 | PERMIT FINALED | JWEATHER | Approved |