Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
C of o
Type:
SINGLE FAMILY NEW
Address:
8392 S OTIS DR
Address NEW:
8392 S OTIS DR
Apply Date:
06/12/2006
Applicant:
D R HORTON HOMES *C
Description:
SFR TD # 16-63-57 T06-M0056
Contractors:
  • D R HORTON HOMES *C

Permit Reviews

Permit Number - T06CM03460
Permit Status: C of o
Permit Description: SFR TD # 16-63-57 T06-M0056
Start Date Submittal Complete Date Status  
06/12/2006 RESIDENTIAL BLDG-MODEL PLAN/ENGINE/WALK THRU 06/14/2006 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T06CM03460
Permit Status: C of o
Permit Description: SFR TD # 16-63-57 T06-M0056
Total Outstanding Activity Conditions - 1
Date Name
06/12/2006 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: C of o
Permit Number: T06CM03460
Permit Description: SFR TD # 16-63-57 T06-M0056
Total Completed Inspections - 23
Date Description Inspector Results Comments
08/24/2006 ELECTRIC - UFER CRUIZ Approved IVRS - Inspection :*
08/24/2006 BUILDING PRE-SLAB CRUIZ Approved IVRS - Inspection :*
08/24/2006 EXCAVATION/LAYOUT REBAR & ZON CRUIZ Approved IVRS - Inspection :*
12/12/2006 PLUMBING - ROUGH, SOIL CRUIZ Approved
12/12/2006 PLUMBING - YARD WTR LINE/TEST CRUIZ Approved NEED ANTI-SIPHON AT HOSE BIB
OK TO BACKFILL
12/12/2006 PLUMBING - SEWER HCS CONNECT CRUIZ Approved IVRS - Inspection :*
12/26/2006 EXT METAL CLIPS/EXT SHEATHING RFREIDIN Approved IVRS - Inspection :
See detailed listing on site.| 999*
1) MISSING WIND BRACING 2ND FLOOR
2) STHD-10 NORTH WALL TO BE IN LINE WITH SHEARWALL RUNNING N. & SOUTH
3) REAR WALL MISSING (D) P.A.'S
4) KITCHEN WINDOW CRIPPLES NOT PLUMB
5) NORTH WALL AT MISSING STHD-10 STRAPM POST TO BEAM SEE 18/D3
6) NAIL BOTTOM PLATE SHEARWALL AT/STAIR 2ND FLOOR
7) MISSING HANGERS ROOF USE CORRECT TYPE
8) DBL TOP PLATE SPLICES TO BE STAGGERED OR USE LARGE FHA STRAPS NORTH WALL
9) WINDOW NORTH WALL ADD CRIPPLES, SHIM HEADER
10) MORE NAILS IN HANGER STAIR, HEADER
11) FROM GIRDER ROOF BLOCK BETWEEN FLOORS UNDER DBL STUDS
12) STRAPS ACROSS FRONT WINDOW NAILS MISSED BLOCKS
13) LOOSE B/PLATE FRONT DOOR
14) MISSING NAILING ON ROOF, MARKED ON FLOOR BELOW, NAIL ALL FRIEZE BLOCKS
15) ?/D6 BLOCKS MISSING
16) FULL LENGTH STUDS LTT20 AT INT. STAIR SHEAR, FINISH H.D.'S STRAP ABOVE
12/26/2006 ROOF NAILING RFREIDIN Approved IVRS - Inspection :
See detailed listing on site.| 999*
01/18/2007 PLUMBING - GAS PRESSURE TEST WNORTH Approved IVRS - Inspection :*
01/18/2007 ELECTRIC - INTERMEDIATE WNORTH Approved IVRS - Inspection :*
01/18/2007 STUCCO MESH WNORTH Approved IVRS - Inspection :*
01/29/2007 MECHANICAL - INTERMEDIATE CTREVILL Approved IVRS - Inspection :*
01/29/2007 PLUMBING - INTERMEDIATE CTREVILL Approved IVRS - Inspection :*
01/29/2007 FRAMING CTREVILL Approved IVRS - Inspection :*
02/06/2007 SHEET ROCK NAILING CRUIZ Approved IVRS - Inspection :*
02/12/2007 ELECTRIC - TEMPORARY SERVICE WLAHR Approved IVRS - Inspection :*
02/12/2007 ELECTRIC - CABLE DROP WLAHR Approved IVRS - Inspection :*
02/13/2007 TEP CLEARANCE - AM JWEATHER Approved ECO CLEARED PER W. LAHR
03/30/2007 MECHANICAL - FINAL WNORTH Approved IVRS - Inspection :*
03/30/2007 PLUMBING - FINAL WNORTH Approved IVRS - Inspection :*
03/30/2007 ELECTRIC - FINAL WNORTH Approved IVRS - Inspection :*
03/30/2007 BUILDING - FINAL WNORTH Approved IVRS - Inspection :*
04/24/2007 PERMIT FINALED JWEATHER Approved

Documents

File Name Document Type  
None DOCUMENTS VIEW
None CONSTRPLANS VIEW
None CERT OF OCC VIEW