Permit: T06CM03460

Parcel: 141332210


Addresses:

8392 S OTIS DR


Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T06CM03460

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
02/05/2007 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
01/04/2007 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
1) MISSING TWO RETRO'S
01/02/2007 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) COMPLY WITH PRIOR INSPECTION
12/26/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) MISSING WIND BRACING 2ND FLOOR
2) STHD-10 NORTH WALL TO BE IN LINE WITH SHEARWALL RUNNING N. & SOUTH
3) REAR WALL MISSING (D) P.A.'S
4) KITCHEN WINDOW CRIPPLES NOT PLUMB
5) NORTH WALL AT MISSING STHD-10 STRAPM POST TO BEAM SEE 18/D3
6) NAIL BOTTOM PLATE SHEARWALL AT/STAIR 2ND FLOOR
7) MISSING HANGERS ROOF USE CORRECT TYPE
8) DBL TOP PLATE SPLICES TO BE STAGGERED OR USE LARGE FHA STRAPS NORTH WALL
9) WINDOW NORTH WALL ADD CRIPPLES, SHIM HEADER
10) MORE NAILS IN HANGER STAIR, HEADER
11) FROM GIRDER ROOF BLOCK BETWEEN FLOORS UNDER DBL STUDS
12) STRAPS ACROSS FRONT WINDOW NAILS MISSED BLOCKS
13) LOOSE B/PLATE FRONT DOOR
14) MISSING NAILING ON ROOF, MARKED ON FLOOR BELOW, NAIL ALL FRIEZE BLOCKS
15) ?/D6 BLOCKS MISSING
16) FULL LENGTH STUDS LTT20 AT INT. STAIR SHEAR, FINISH H.D.'S STRAP ABOVE
12/01/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
Work is not complete enough to inspect.| 950*
1) NO OSHA APPROVED ACCESS TO ROOF
2) NO TRUSS DRAWINGS ON SITE
3) CLIP STUDS TOP AND BOTTOM THAT HAVE CS 20 STRAPS
4) 2/D2 KNEE BRACES NOT INSTALLED
5) 19/D3 NOT COMPLIED WITH REAR PORCH
6) HPAHD 22 MISSING AT PATIO DOOR-PROVIDE CITY OF TUCSON/ENGINEERS APPROVED REPAIR
7) HPAHD 22 HOLDOWN IN WRONG LOCATION BY ENTRY. MUST BE ON POST UNDER SHEARWALL ABOVE. PROVIDE CITY OF TUCSON ENGINEERS APPROVED REPAIR
8) STOPPED INSPECTION-TOO MANY ITEMS