Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
C of o
Type:
COMMERCIAL NEW
Address:
6044 E 30TH ST
Address NEW:
6044 E 30TH ST
Apply Date:
06/12/2006
Applicant:
SHAMBACH, DAVID E.
Description:
NEW OFFICE BLDG
Architects:
  • SHAMBACH, DAVID E.
Contractors:
  • TUCSON BUILDING AND REMODELING I

Permit Reviews

Permit Number - T06CM03457
Permit Status: C of o
Permit Description: NEW OFFICE BLDG
Start Date Submittal Complete Date Status  
02/08/2007 3RD PARTY REVIEW-REVISION/OTHER 02/08/2007 COMPLETED Review Details
04/05/2007 3RD PARTY REVIEW-REVISION/OTHER 04/05/2007 COMPLETED Review Details
06/12/2006 PLANS OK TO SUBMIT - 3RD PARTY 06/12/2006 COMPLETED Review Details
06/12/2006 3RD PARTY REVIEW-COMMERCIAL TI 07/18/2006 COMPLETED Review Details
07/06/2007 REVISION - - 1ST 07/06/2007 COMPLETED Review Details
08/21/2006 POST 3RD PARTY REVIEW 09/14/2006 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T06CM03457
Permit Status: C of o
Permit Description: NEW OFFICE BLDG
Total Outstanding Activity Conditions - 1
Date Name
08/21/2006 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: C of o
Permit Number: T06CM03457
Permit Description: NEW OFFICE BLDG
Total Completed Inspections - 37
Date Description Inspector Results Comments
11/16/2006 PLUMBING - YARD WTR LINE/TEST BBENEDON Approved IVRS - Inspection :*
11/20/2006 SITE - SEWER BBENEDON Approved IVRS - Inspection :*
SITE SEWER FROM TWO WAY CLEANOUT TO PROPERTY LINE IS OK TO COVER.
HCS CONNECTION ON ADJACENT PROPERTY IS NOT PER PLAN.
HCS CONNECTION APPROVAL IS SUBJECT TO PLAN REVISION.
11/29/2006 PLUMBING - SEWER HCS CONNECT RRICH Approved IVRS - Inspection :*
FROM BUILDING WATER TEST DOWNSTREAM TO EXISTING HCS STUB ON PROPERTY OF 6026 E. 30TH. ST.
1. SHALL PROVIDE LEGAL DOCUMENT GIVING RIGHT OF WAY FOR SEWER ON ANOTHER OWNERS PROPERTY.
2. SHALL PROVIDE UNDERGROUND RATED WIRE NOT FOR TRACER WIRE.
3. SHALL INSTALL CLEANOUT NOT TO EXCEED 100' INCLUDING RISE BETWEEN PROPERTY LINE CLEANOUT & 1ST UPSTREAM CLEANOUT & PROVIDE TEST.
12/06/2006 PLUMBING - ROUGH, SOIL RRICH Approved IVRS - Inspection :*
VENT FOR SHOWER OK

SHALL RETEST FOR P-TRAP INSTALLATION OF SHOWER.
12/06/2006 PLUMBING - PRE SLAB RRICH Approved IVRS - Inspection :*
12/07/2006 BUILDING PRE-SLAB GDABBS Approved IVRS - Inspection :*
12/07/2006 EXCAVATION/LAYOUT REBAR & ZON GDABBS Approved IVRS - Inspection :*
12/08/2006 ELECTRIC - UFER RMAJUTA Approved IVRS - Inspection :*
01/09/2007 ROOF NAILING GDABBS Approved IVRS - Inspection :*
01/09/2007 EXT METAL CLIPS/EXT SHEATHING GDABBS Approved IVRS - Inspection :*
02/20/2007 STUCCO MESH GDABBS Approved IVRS - Inspection :*
NOTE: REINSPECTED ROOF NAILING -- OK TO ROOF
03/05/2007 MECHANICAL - INTERMEDIATE JMILITEL Approved IVRS - Inspection :*
1. PLANS & CODE REQUIRE R5 DUCT INSULATION
R4.2 WAS USED.
2. PLANS MAY HAVE BEEN APPROVED IN ERROR 1 1/2" DUCT INSULATION IS NOT ADEQUATE.
3. PROVIDE BACKING AROUND CEILING BOXES.
4. PROVIDE CONDENSATE DRAIN LINE.
5. DO NOT SUPPORT DUCTING WITH 2X4'S PILED UP UNDER DUCT.
03/05/2007 ELECTRIC - INTERMEDIATE RMAJUTA Approved
03/05/2007 FRAMING GDABBS Approved IVRS - Inspection :*
03/19/2007 PLUMBING - INTERMEDIATE RRICH Approved IVRS - Inspection :*
03/27/2007 SHEET ROCK NAILING GDABBS Approved IVRS - Inspection :*
04/25/2007 MECHANICAL - ABOVE CEILING JMILITEL Approved IVRS - Inspection :*
OK FOR CEILING TILES
PROVIDE A OVERFLOW SENSOR ON SECONDARY DRAIN OUTLET
05/24/2007 ELECTRIC - OUTDOOR LIGHTING RJIROUDE Approved IVRS - Inspection :*
05/30/2007 TEP CLEARANCE - AM JWEATHER Approved ECO CLEARED FOR #1 PER R. MAJUTA
06/14/2007 MECHANICAL - FINAL AALEGRIA Approved IVRS - Inspection :*
1) THIS INSPECTION IN COMPLIANCE WITH SECTION 104.4 AND 107.1 (B) FINAL INSPECTION IN ACCORDANCE WITH IMC AND APPROVED PLANS
06/14/2007 FIRE - FINAL CSCHULTZ Approved
06/14/2007 NPPO - FINAL ACONNOR Approved
06/14/2007 LANDSCAPE - FINAL ACONNOR Approved
06/14/2007 U VALUE FOR WINDOW GDABBS Approved IVRS - Inspection :*
06/14/2007 RIGHT OF WAY - FINAL SDAMRON Approved PER EMAIL
07/10/2007 ENGINEERING - FINAL NKALAHAR Approved ALL ITEMS HAVE BEEN ADDRESSED FROM 6/14 INSPECTION
SWALE WAS REMOVED FROM PLANS
SITE IS NOW STABILIZED
SPLASH BLOCKS IN PLACE
DUMPSTER WAS REMOVED
07/10/2007 OUTDOOR LIGHTING FINAL RJIROUDE Approved IVRS - Inspection :*
07/10/2007 ELECTRIC - FINAL RJIROUDE Approved IVRS - Inspection :*
07/10/2007 PLUMBING - FINAL RRICH Approved IVRS - Inspection :*
07/10/2007 BUILDING - FINAL GDABBS Approved IVRS - Inspection :*
07/10/2007 SIGN - FINAL JYBARRA Approved IVRS - Inspection :*
07/11/2007 PERMIT FINALED GDABBS Approved
07/11/2007 MECHANICAL - UNDERGROUND AALEGRIA Approved
07/11/2007 ELECTRIC - UNDERGROUND RJIROUDE Approved
07/11/2007 ELECTRIC - CABLE DROP RJIROUDE Approved
07/11/2007 ELECTRIC - TEMPORARY SERVICE RJIROUDE Approved
07/11/2007 ELECTRIC - CONSTRUCTION POWER RJIROUDE Approved

Documents

File Name Document Type  
None DOCUMENTS VIEW
None CERT OF OCC VIEW
30THST.JPG SIGNS VIEW
T06CM03457-R4_001.TIF CONSTRPLANS VIEW
T06CM03457-R4_002.TIF CONSTRPLANS VIEW
T06CM03457-R3_01.TIF CONSTRPLANS VIEW
T06CM03457-R3_02.TIF CONSTRPLANS VIEW
REVISION2.TIF CONSTRPLANS VIEW
3457-01-0002-01-0002.TIF CONSTRPLANS VIEW
3457-01-0002-01-0003.TIF CONSTRPLANS VIEW
3457-01-0002-01-0004.TIF CONSTRPLANS VIEW
REVISION1.TIF CONSTRPLANS VIEW
ORIGINAL.TIF CONSTRPLANS VIEW
3457-01-0001-01-0003.TIF CONSTRPLANS VIEW
3457-01-0001-01-0004.TIF CONSTRPLANS VIEW
3457-01-0001-01-0005.TIF CONSTRPLANS VIEW
3457-01-0001-01-0006.TIF CONSTRPLANS VIEW
3457-01-0001-01-0007.TIF CONSTRPLANS VIEW
3457-01-0001-01-0008.TIF CONSTRPLANS VIEW
3457-01-0001-01-0009.TIF CONSTRPLANS VIEW