Permit: T06CM03457

Parcel: 131120280


Addresses:

6044 E 30TH ST

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
03/19/2007 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
03/15/2007 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
1. PLEASE SEE REQUIREMENTS FOR SHOWER VALVE LOCATION IN 36" X 36" TRANSFER SHOWER. VALVE SHALL BE 38"-48" ABOVE FINISHED FLOOR DIRECTLY OPPOSITE SEAT
PAGE 57, 58, 59 2003 AMERICAN NATIONAL STANDARD ICC ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES BOOK.
2. INSTALL CLOSET FLANGE FOR INSPECTION PER INSTALLATION STANDARD #5 2003 UPC PRIOR TO SETTING STOOL.
03/05/2007 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
WATER TEST WASTE & VENT THRU ROOF OK
WATER PIPING OK
1. SHALL SEE FINAL INSTALL OF H/C SHOWER WITH SHOWER VALVE INSTALL PROPERLY SUPPORTED.
2. SUPPORT 3" VENT OVERHEAD IN RESTROOM