Permit: T06CM03421
Permit Details
Apply Date:
06/08/2006
Applicant:
ARCHITECTURAL DESIGN GROUP INC
Description:
TI: PAWN SHOP
Architects:
- ARCHITECTURAL DESIGN GROUP INC
Contractors:
- DIVISION II CONSTRUCTION COMPANY
Permit Reviews
Permit Number - T06CM03421
Permit Status: Expired
Permit Description: TI: PAWN SHOP
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 06/08/2006 | PLANS OK TO SUBMIT - 3RD PARTY | 06/09/2006 | COMPLETED |
| 06/09/2006 | 3RD PARTY REVIEW-COMMERCIAL TI | 06/27/2006 | COMPLETED |
| 06/27/2006 | POST 3RD PARTY REVIEW | 06/29/2006 | COMPLETED |
| 07/03/2006 | RESUBMITTAL | 07/05/2006 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T06CM03421
Permit Status: Expired
Permit Description: TI: PAWN SHOP
Total Outstanding Activity Conditions - 3
| Date | Name |
|---|---|
| 06/08/2006 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
| 06/27/2006 | SPECIAL INSPECTION FOR FIELD WELDING IS REQUIRED. |
| 06/27/2006 | SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T06CM03421
Permite Description: TI: PAWN SHOP
Total Outstanding Inspections - 4
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/04/2006 | BUILDING - FINAL | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. 12" ADDRESS DISPLAY REQUIRED PER PCZO AT FRONT OF BUILDING. 2. NON-ACCESSIBLE THRESHOLDS AT RESTROOMS AND PATH TO RESTROOM (MUST COMPLY WITH ANSI 117.1) 3. MUST PROVIDE NON-PERMEABLE WALL SURFACE BEHIND W.C'S 4. NOTE: MOBILE MINI INSTALLED ON SOUTHSIDE MUST BE APPROVED BY ZONING & ENGINEERING. |
| 12/04/2006 | ELECTRIC - INTERMEDIATE | N/A | Denied | IVRS - Inspection : The wiring is not complete or does not comply with code.| 245* |
| 12/04/2006 | ELECTRIC - FINAL | N/A | Denied | IVRS - Inspection : The wiring is not complete or does not comply with code.| 245* 1. IDENTIFY PANEL "B" DISCONNECT & PROPERLY GROUND IT 2. REIDENTIFY PANEL "A" DIRECTORY 3. REVISE PLANS TO SHOW ACTUAL SCOPE OF WORK 4. CORRECTLY IDENTIFY PANEL "B" PANEL DIRECTORY AND STRAP FEEDER EMT WITHIN 3' OF PANEL. 5. MAX 20 AMP OVERCURRENT ON INSTA-HOTS, STRAP FLEX AND DISCONNECT TO DISCONNECT ALL HOTS - 2 POLE SWITCH? 6. STORAGE ROOM EMERGENCY LIGHT NOT WORKING AND IS BLOCKED BY STORAGE RACK. 7. TIGHTEN LOOSE DEVICES, REPLACE CRACKED PLATES 8. MAX 360 DEG. IN RACEWAYS -- BOX TO PANEL 9. PROVIDE ACCESS TO J-BOX 10. GROUND ALL J-BOXES SHEET METAL SCREWS NOT ALLOWED. |
| 12/04/2006 | SIGN - FINAL | N/A | Partial Approval | IVRS - Inspection :*TEMP C/O; MUST FINAL ELEC ON TO6OT02140 AND MUST PERMIT OR REMOVE BANNER ON DF |
Completed Inspections
Permit Status: Expired
Permit Number: T06CM03421
Permit Description: TI: PAWN SHOP
Total Completed Inspections - 17
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/26/2006 | FRAMING | AQUIROZ | Approved | IVRS - Inspection :* EXCLUDES RESTROOM |
| 07/26/2006 | EXCAVATION/LAYOUT REBAR & ZON | AQUIROZ | Approved | IVRS - Inspection :* |
| 08/23/2006 | EXT METAL CLIPS/EXT SHEATHING | AQUIROZ | Approved | IVRS - Inspection :* |
| 08/30/2006 | U VALUE FOR WINDOW | AQUIROZ | Approved | IVRS - Inspection :* |
| 09/19/2006 | STUCCO MESH | AQUIROZ | Approved | IVRS - Inspection :* |
| 10/31/2006 | PLUMBING - ROUGH, SOIL | RLEDONNE | Approved | IVRS - Inspection :* |
| 11/08/2006 | ELECTRIC - CABLE DROP | IVR USER | Approved | IVRS - AP canceled |
| 11/14/2006 | PLUMBING - INTERMEDIATE | RMYERS | Approved | IVRS - Inspection :* OK TO COVER ALL AREAS |
| 11/14/2006 | PLUMBING - PRE SLAB | RMYERS | Approved | IVRS - Inspection :* |
| 11/17/2006 | SHEET ROCK NAILING | AQUIROZ | Approved | IVRS - Inspection :* |
| 12/04/2006 | RIGHT OF WAY - FINAL | MOTERO | Approved | PER EMAIL |
| 12/04/2006 | MECHANICAL - FINAL | JMILITEL | Approved | IVRS - Inspection :* OK FOR FINAL |
| 12/04/2006 | MECHANICAL - INTERMEDIATE | JMILITEL | Approved | IVRS - Inspection :* |
| 12/04/2006 | PLUMBING - FINAL | RMYERS | Approved | IVRS - Inspection :* |
| 12/04/2006 | FIRE - FINAL | LTHOMAS | Approved | |
| 12/04/2006 | NPPO - FINAL | ACONNOR | Approved | |
| 12/04/2006 | LANDSCAPE - FINAL | ACONNOR | Approved |