Permit Reviews

Permit Number - T06CM03031
Permit Status: Final
Permit Description: SHELL BUILDING
Start Date Submittal Complete Date Status  
05/22/2006 PLANS OK TO SUBMIT - 3RD PARTY 05/22/2006 COMPLETED Review Details
05/22/2006 3RD PARTY REVIEW-COMMERCIAL 08/08/2006 COMPLETED Review Details
05/23/2007 RESUBMITTAL 05/23/2007 COMPLETED Review Details
07/20/2006 SITE 10/13/2006 COMPLETED Review Details
08/08/2006 POST 3RD PARTY REVIEW 10/13/2006 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T06CM03031
Permit Status: Final
Permit Description: SHELL BUILDING
Total Outstanding Activity Conditions - 1
Date Name
05/22/2006 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: Final
Permit Number: T06CM03031
Permit Description: SHELL BUILDING
Total Completed Inspections - 33
Date Description Inspector Results Comments
05/31/2007 ELECTRIC - UFER RJIROUDE Approved IVRS - Inspection :*
OK 40' 2/0 COPPER IN FOOTING FOR UFER
06/13/2007 PLUMBING - PRE SLAB BBENEDON Approved IVRS - Inspection :*
06/14/2007 BUILDING PRE-SLAB JBURGE Approved IVRS - Inspection :*
1) AB, VAPOR BARRIER-POST TREATMENT; 4" OF SAND OK TO POUR
07/18/2007 REINFORCED MASONRY PRE-GROUT JBURGE Approved IVRS - Inspection :*
ALL EXTERIOR WALLS ARE TOPPED OUT AS PER ELEVATION PLANS -- OK TO GROUT & CAP
LINE A/3 TO A.75/5
08/29/2007 EXCAVATION/LAYOUT REBAR & ZON JBURGE Approved LOADING DOCK - OK TO POUR RAMP
10/05/2007 ROOF NAILING JBURGE Approved IVRS - Inspection :*
FINAL TRUSS IN PLACE, CORRUGATED METAL ROOF SYSTEM DRIED IN
10/17/2007 ELECTRIC - INTERMEDIATE CCLEMENS Approved IVRS - Inspection :*
OK SERVICE SECONDARY RACEWAY COVER - INSTALL WARNING RIBBON - NEC 300.5 D3 (2 -3" PVC)
10/18/2007 PLUMBING - SEWER HCS CONNECT RRICH Approved IVRS - Inspection :*
APPROVED PLAN ON SITE
10/26/2007 PLUMBING - ROOF DRAINS RRICH Approved IVRS - Inspection :*
6" OFRD AT NORTHEAST WATER TEST OK
10/26/2007 PLUMBING - FINAL RRICH Approved IVRS - Inspection :*
10/26/2007 PLUMBING - YARD WTR LINE/TEST RRICH Approved IVRS - Inspection :*
10/26/2007 PLUMBING - ROUGH, SOIL RRICH Approved IVRS - Inspection :*
11/01/2007 FRAMING JBURGE Approved MAIN ENTRY CANOPY & EAST CANOPY - APPROVED
11/01/2007 U VALUE FOR WINDOW JBURGE Approved IVRS - Inspection :*
3/16 CLEAR TEMPERED GLASS SYSTEM
11/01/2007 STUCCO MESH JBURGE Approved IVRS - Inspection :*
STUCCO SYSTEM APPLIED EXCEPT @ MAIN ENTRY & CANOPY
11/01/2007 EXT METAL CLIPS/EXT SHEATHING JBURGE Approved IVRS - Inspection :*
PLYWOOD SHEATHING @ MAIN ENTRY
11/01/2007 SHEET ROCK NAILING JBURGE Approved IVRS - Inspection :*
01/31/2008 RIGHT OF WAY - FINAL MOTERO Approved PER EMAIL
01/31/2008 ELECTRIC - FINAL RJIROUDE Approved IVRS - Inspection :*
SHELL BUILDING ONLY NO POWER
TO BE TURNED ON AT THIS TIME.
01/31/2008 OUTDOOR LIGHTING FINAL RJIROUDE Approved IVRS - Inspection :*
01/31/2008 ELECTRIC - OUTDOOR LIGHTING RJIROUDE Approved IVRS - Inspection :*
01/31/2008 ELECTRIC - CONSTRUCTION POWER RJIROUDE Approved IVRS - Inspection :*
01/31/2008 ELECTRIC - TEMPORARY SERVICE RJIROUDE Approved IVRS - Inspection :*
01/31/2008 ELECTRIC - CABLE DROP RJIROUDE Approved IVRS - Inspection :*
01/31/2008 SIGN - FINAL JYBARRA Approved IVRS - Inspection :*
01/31/2008 NPPO - FINAL ACONNOR Approved
01/31/2008 LANDSCAPE - FINAL ACONNOR Approved
01/31/2008 MECHANICAL - FINAL MRAMBER Approved IVRS - Inspection :*
01/31/2008 MECHANICAL - INTERMEDIATE MRAMBER Approved IVRS - Inspection :*
02/01/2008 ENGINEERING - FINAL MRUSSO Approved
02/01/2008 FIRE SPKLR - FINAL LTHOMAS Approved
02/01/2008 FIRE - FINAL LTHOMAS Approved
02/01/2008 BUILDING - FINAL JBURGE Approved

Documents

File Name Document Type  
STRUCCALC.TIF DOCUMENTS VIEW
REPORT OF SPECIAL INSPECTION.TIF DOCUMENTS VIEW
None DOCUMENTS VIEW
3031-01-0001-01-ORIGINAL001.TIF CONSTRPLANS VIEW
3031-01-0001-01-ORIGINAL002.TIF CONSTRPLANS VIEW
3031-01-0001-01-ORIGINAL003.TIF CONSTRPLANS VIEW
3031-01-0001-01-ORIGINAL004.TIF CONSTRPLANS VIEW
3031-01-0001-01-ORIGINAL005.TIF CONSTRPLANS VIEW
3031-01-0001-01-ORIGINAL006.TIF CONSTRPLANS VIEW
3031-01-0001-01-ORIGINAL007.TIF CONSTRPLANS VIEW
3031-01-0001-01-ORIGINAL008.TIF CONSTRPLANS VIEW
3031-01-0001-01-ORIGINAL009.TIF CONSTRPLANS VIEW
3031-01-0001-01-ORIGINAL010.TIF CONSTRPLANS VIEW
3031-01-0001-01-ORIGINAL011.TIF CONSTRPLANS VIEW
3031-01-0001-01-ORIGINAL012.TIF CONSTRPLANS VIEW
3031-01-0001-01-ORIGINAL013.TIF CONSTRPLANS VIEW
3031-01-0001-01-ORIGINAL014.TIF CONSTRPLANS VIEW
3031-01-0001-01-ORIGINAL015.TIF CONSTRPLANS VIEW
3031-01-0001-01-ORIGINAL016.TIF CONSTRPLANS VIEW
3031-01-0001-01-ORIGINAL017.TIF CONSTRPLANS VIEW
3031-01-0001-01-ORIGINAL018.TIF CONSTRPLANS VIEW
3031-01-0001-01-ORIGINAL019.TIF CONSTRPLANS VIEW
3031-01-0001-01-ORIGINAL020.TIF CONSTRPLANS VIEW
3031-01-0001-01-ORIGINAL021.TIF CONSTRPLANS VIEW
3031-01-0001-01-ORIGINAL022.TIF CONSTRPLANS VIEW
3031-01-0001-01-ORIGINAL023.TIF CONSTRPLANS VIEW
3031-01-0001-01-ORIGINAL024.TIF CONSTRPLANS VIEW
3031-01-0001-01-ORIGINAL025.TIF CONSTRPLANS VIEW