Inspection History Details
Inspection Status: Approved
Inspection History: REINFORCED MASONRY PRE-GROUT
Permit Number - T06CM03031
Inspection Description - REINFORCED MASONRY PRE-GROUT
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/18/2007 | REINFORCED MASONRY PRE-GROUT | Approved | IVRS - Inspection :* ALL EXTERIOR WALLS ARE TOPPED OUT AS PER ELEVATION PLANS -- OK TO GROUT & CAP LINE A/3 TO A.75/5 |
|
07/17/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* NORTH WALL - A/3 TO A/4.75; NE & E WALL 4/4.75 TO B/5 @ 24' OK TO GROUT |
|
07/16/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* NORTHWALL @ 20'; LINE A/3 TO A/4.5, NE CORNER @ 20' LINE A/4.5 TO A-8/5 OK TO GROUT |
|
07/13/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* LINE A/3 TO B/5 @ 54" ABOVE BEAM OK TO GROUT & SET EMBEDS |
|
07/05/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* SE WALLS LINES D.5/5 - D.5/5.5; D.5/5.5 TO E/6 NE POPOUTS - TOPPED OUT -- OK TO GROUT PROGRESS AREAS |
|
07/03/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* SOUTH WALL @ 27' LINE E/2 - E/3; NORTH & NW POP-OUTS @ 20' OK TO GROUT PROGRESS AREAS |
|
07/02/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 2 @ PIERS @ 11'4", A/4.7 TO A.5/5; EAST WALL @ 24'8" LINE A/5 TO D.5/5 D.5/5 TO D.5/6 @ 24'8", D.5/6 TO E/6, E/6 TO E/1 @ 24'8" SW POPOUTS @ 20' --- OK TO GROUT PROGRESS AREAS |
|
06/29/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* EAST WALL B.5/1 TO C.5/1 2 20'8" POPOUTS A/1.2 TO A/3' D.5/1 TO E/1.2 @ 16' -- OK TO GROUT |
|
06/28/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* EAST WALL A/5 TO E/6 @ 20'8" SOUTH WALL E/1 TO E/6 WEST WALL D/1 TO E/1; B.25/1 TO A/1.2 @ 20'8" POPOUTS @ 12'; C/1 & C.5/1 @ 16' OK TO GROUT PROGRESS AREAS |
|
06/27/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 2 @ PIERS @ A/4.8 AND A.25/5 - 8' - OK TO GROUT POPOUTS ON NORTH, WEST & SOUTH WALLS (3RD LIFT) OK TO GROUT |
|
06/26/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* LINE A/5 TO D.5/5; D.5/5 TO D/6; D/6 TO E/6; E/6 TO E/4.5 LINE C/1 TO A/1; A/1 TO A/3 @ 16'8" OK TO GROUT |
|
06/25/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* LINE E/1 TO E/5 @ 12'8 TO 16'8; LINE D/5 TO D/6; D/6 TO E/5 @ 12'8" -- OK TO GROUT |
|
06/22/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* NORTH WALL @ 12' LINE A/1 TO A/3; WEST WALL @ 12' LINE A/1 TO E/1 SOUTH WALL @ 12' LINE E/1 TO E/5 EAST WALL @ 12' LINE A/5 TO E/5 ALL POPOUTS @ 2ND LIFT OK TO GROUT |
|
06/21/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* LINES E/1 TO E/6 @ 12'; B.5/1 TO E/1 @ 12' POPOUTS A/1 TO A/3 @ 4'8"; B.5/1 TO E/1; E/1 TO E/1.2 WALL: A/1 TO P 1/3 @ 8' -- OK TO GROUT |
|
06/20/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* A/1.2 TO A/3 @ 4' A/5 TO E/6 @ 8' E/1 TO E/6 @ 8' A/1 TO E/1 @ @ 8' OK TO GROUT |
|
06/19/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* FIRST LIFT 2 4' LINES E/6 TO E/1; TO A/1 OK TO GROUT |
|
06/12/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* EAST LOADING DOCK WALL - TOPPED OUT @ 10' BOND BEAM W/2 @ #4'S -- OK TO GROUT |
|
06/11/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* EAST LOADING DOCK WALL @ 4'8" -- OK TO GROUT |
|
06/07/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* CONTINUOUS FOOTINGS @ 24" - COLUMN FOOTINGS @ 24" LOADING DOCK AREA - BOND BEAM @ 16" - REBAR @ 8" O.C FOOTING @ 64" OK TO POUR |