Permit: T06CM03030
Permit Details
Apply Date:
05/22/2006
Applicant:
ME DEVELOPMENT
Description:
TOWN HOME TD # 16-48-04 T05-M0206
Contractors:
- BOBRU CONSTRUCTION L L C
Permit Reviews
Permit Number - T06CM03030
Permit Status: C of o
Permit Description: TOWN HOME TD # 16-48-04 T05-M0206
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
05/22/2006 | RESIDENTIAL BLDG-MODEL PLAN/ENGINE/WALK THRU | 06/02/2006 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T06CM03030
Permit Status: C of o
Permit Description: TOWN HOME TD # 16-48-04 T05-M0206
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
05/22/2006 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T06CM03030
Permit Description: TOWN HOME TD # 16-48-04 T05-M0206
Total Completed Inspections - 30
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/23/2006 | PLUMBING - ROUGH, SOIL | RMYERS | Approved | IVRS - Inspection :* 1. PVC DWV UNDERGROUND OK TO COVER 2. PVC SEWER OK TO COVER |
06/23/2006 | PLUMBING - SEWER HCS CONNECT | RMYERS | Approved | IVRS - Inspection :* |
07/28/2006 | BUILDING PRE-SLAB | AQUIROZ | Approved | IVRS - Inspection :* |
07/28/2006 | EXCAVATION/LAYOUT REBAR & ZON | AQUIROZ | Approved | IVRS - Inspection :* |
07/28/2006 | ELECTRIC - UFER | CCLEMENS | Approved | IVRS - Inspection :* |
12/14/2006 | EXT METAL CLIPS/EXT SHEATHING | AALEGRIA | Approved | IVRS - Inspection :* |
12/18/2006 | FRAMING | JBURGE | Approved | IVRS - Inspection :* ENSURE ALL FIRE BLOCKING IS PROPERLY INSTALLED; ALL DUCT VENTS & EXHAUST FANS ARE BLOCKED ON THREE SIDES. |
12/18/2006 | ROOF NAILING | JBURGE | Approved | IVRS - Inspection :* 1. ALL ROOF AREAS EXCEPT REAR PATIO & MAIN ENTRY AREAS RECALL WHEN METAL ROOF SYSTEM IS INSTALLED. |
12/28/2006 | ELECTRIC - INTERMEDIATE | CCLEMENS | Approved | IVRS - Inspection : The wiring is not complete or does not comply with code.| 245* INSPECTION FOR COMMON WALL ONLY: 1) NAILS NOT ALLOWED IN BOXES-NEC 314.23 B1 2) DISPOSAL SWITCH BOX OVER FILLED-NEC 314.16 3) FINISH WIRING TO COUNTER RECEPTACLES 4) NAIL PLATE AS NEEDED-NEC 300.4 |
02/08/2007 | REINFORCED MASONRY PRE-GROUT | JBURGE | Approved | IVRS - Inspection :* 1) FIREPLACE AT 12' OK TO GROUT |
02/15/2007 | MECHANICAL - INTERMEDIATE | JMILITEL | Approved | IVRS - Inspection :* OK FOR SHEETROCK |
02/15/2007 | STUCCO MESH | JBURGE | Approved | IVRS - Inspection :* OK TO STUCCO |
02/15/2007 | PLUMBING - GAS PRESSURE TEST | BBENEDON | Approved | IVRS - Inspection :* |
02/15/2007 | U VALUE FOR WINDOW | JBURGE | Approved | IVRS - Inspection :* |
02/23/2007 | SHEET ROCK NAILING | JBURGE | Approved | IVRS - Inspection :* OK TO TAPE & TEXTURE |
05/10/2007 | ELECTRIC - TEMPORARY SERVICE | CCLEMENS | Approved | IVRS - Inspection :* |
05/10/2007 | ELECTRIC - CABLE DROP | CCLEMENS | Approved | IVRS - Inspection :* |
05/11/2007 | TEP CLEARANCE - AM | JWEATHER | Approved | TEC CLEARED PER C. CLEMENS |
07/30/2007 | SITE - SEWER | RMYERS | Approved | IVRS - Inspection :* |
07/30/2007 | PLUMBING - GAS PRESS TEST FNL | RMYERS | Approved | IVRS - Inspection :* |
07/30/2007 | PLUMBING - PROGRESS | RMYERS | Approved | IVRS - Inspection :* |
07/30/2007 | BUILDING - FINAL | AQUIROZ | Approved | IVRS - Inspection :* |
07/31/2007 | ELECTRIC - FINAL | DWALKER | Approved | IVRS - Inspection :* |
07/31/2007 | BUILDING - PROGRESS | AQUIROZ | Approved | |
08/01/2007 | PLUMBING - FINAL | RMYERS | Approved | |
08/01/2007 | MECHANICAL - FINAL | JBURGE | Approved | IVRS - Inspection :* |
08/02/2007 | ASSURANCE | MCARREON | Approved | |
08/02/2007 | OUTDOOR LIGHTING FINAL | DWALKER | Approved | |
08/02/2007 | ELECTRIC - PROGRESS | DWALKER | Approved | |
08/02/2007 | ELECTRIC - OUTDOOR LIGHTING | DWALKER | Approved |