Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T06CM03030

Parcel: 112081040


Addresses:

2896 E CANNES ST


Inspection Status: Approved

Inspection History: MECHANICAL - FINAL

Permit Number - T06CM03030

Inspection Description - MECHANICAL - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
08/01/2007 MECHANICAL - FINAL Approved IVRS - Inspection :*
07/30/2007 MECHANICAL - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
- GAS FLEX NOT SIZED CORRECTLY
- PAINT PVC W/LATEX PAINT
- PROVIDE MIN. 3 SCREWS IN ALL JOINTS OF WATER HEATER VENT CONNECTOR.
- PROVIDE SCREEN IN EXHAUST FAN T-TOP