Permit: T06CM02574
Permit Details
Apply Date:
05/01/2006
Applicant:
N/A
Description:
TOWNHOUSE:TD#16-49-76 T05-M0258
Contractors:
- BOBRU CONSTRUCTION L L C
Permit Reviews
Permit Number - T06CM02574
Permit Status: C of o
Permit Description: TOWNHOUSE:TD#16-49-76 T05-M0258
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 05/01/2006 | RESIDENTIAL BLDG-MODEL PLAN/ENGINE/WALK THRU | 05/02/2006 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T06CM02574
Permit Status: C of o
Permit Description: TOWNHOUSE:TD#16-49-76 T05-M0258
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 05/01/2006 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T06CM02574
Permit Description: TOWNHOUSE:TD#16-49-76 T05-M0258
Total Completed Inspections - 27
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/28/2006 | PLUMBING - ROUGH, SOIL | RMYERS | Approved | IVRS - Inspection :* 1) PVC DWV UNDERGROUND OK. WATER TEST ONE RISER TO TEN FEET 2) PVC SEWER TO HCS CONNECTION OK. OK TO COVER UNDERGROUND |
| 06/28/2006 | PLUMBING - SEWER HCS CONNECT | RMYERS | Approved | IVRS - Inspection :* |
| 07/07/2006 | ELECTRIC - UFER | CCLEMENS | Approved | IVRS - Inspection :* |
| 07/07/2006 | BUILDING PRE-SLAB | AALEGRIA | Approved | IVRS - Inspection :* |
| 07/07/2006 | EXCAVATION/LAYOUT REBAR & ZON | AALEGRIA | Approved | IVRS - Inspection :* |
| 09/28/2006 | U VALUE FOR WINDOW | AQUIROZ | Approved | IVRS - Inspection :* INCOMPLETE |
| 09/29/2006 | PLUMBING - INTERMEDIATE | RMYERS | Approved | IVRS - Inspection :* |
| 10/12/2006 | FRAMING | LHANLY | Approved | IVRS - Inspection : See detailed listing on site.| 999* 1. NEED PETITION TO BUILDING OFFICIAL OFFICIAL FOR PLUMBING KICKOUT AT COMMON WALL. 2. REMOVE ALL PLUMBING FROM COMMON WALLS. 3. REVISE PLAN FOR MECH. EXHAUST VENT RELOCATION (WATER HEATER) |
| 10/12/2006 | MECHANICAL - INTERMEDIATE | CWILLIAM | Approved | IVRS - Inspection :* APP. PLAN SHOWS B-1 WATER HTR. VENT UP THRU ROOF AS INSTALLED, ITS OFFSETTING THRU GARAGE IF ACCEPTABLE AS INSTALLED, TOTAL VERTICAL WILL NEED TO BE 25% LONGER THAN THE HORIZONTAL. |
| 10/12/2006 | ROOF NAILING | LHANLY | Approved | IVRS - Inspection :* |
| 10/12/2006 | EXT METAL CLIPS/EXT SHEATHING | LHANLY | Approved | IVRS - Inspection :* |
| 10/13/2006 | ELECTRIC - INTERMEDIATE | RMAJUTA | Approved | IVRS - Inspection :* |
| 02/05/2007 | PLUMBING - GAS PRESSURE TEST | RMYERS | Approved | IVRS - Inspection :* |
| 02/21/2007 | STUCCO MESH | AQUIROZ | Approved | IVRS - Inspection :* |
| 03/05/2007 | SHEET ROCK NAILING | AQUIROZ | Approved | IVRS - Inspection :* |
| 04/06/2007 | ELECTRIC - TEMPORARY SERVICE | RJIROUDE | Approved | IVRS - Inspection :* |
| 04/06/2007 | ELECTRIC - CABLE DROP | RJIROUDE | Approved | IVRS - Inspection :* |
| 04/09/2007 | TEP CLEARANCE - AM | JWEATHER | Approved | TMPP CLEARED PER R. JIROUDEK |
| 04/30/2007 | MECHANICAL - FINAL | JMILITEL | Approved | IVRS - Inspection :* |
| 04/30/2007 | BUILDING - FINAL | AQUIROZ | Approved | IVRS - Inspection :* |
| 04/30/2007 | BUILDING - PROGRESS | AQUIROZ | Approved | IVRS - Inspection :* |
| 04/30/2007 | ELECTRIC - FINAL | CCLEMENS | Approved | IVRS - Inspection :* |
| 04/30/2007 | OUTDOOR LIGHTING FINAL | CCLEMENS | Approved | IVRS - Inspection :* |
| 04/30/2007 | ELECTRIC - OUTDOOR LIGHTING | CCLEMENS | Approved | IVRS - Inspection :* |
| 05/01/2007 | PERMIT FINALED | BFLORES | Approved | |
| 05/01/2007 | PLUMBING - FINAL | RMYERS | Approved | IVRS - Inspection :* PLUMBING FINAL OK OK FOR C OF O |
| 05/01/2007 | PLUMBING - GAS PRESS TEST FNL | RMYERS | Approved | IVRS - Inspection :* |