Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
C of o
Type:
SINGLE FAMILY NEW
Apply Date:
04/19/2006
Applicant:
N/A
Description:
TH: TD#16-65-37 T06-M0067
Contractors:
  • LOUIS MARSON AND SONS INC

Permit Reviews

Permit Number - T06CM02256
Permit Status: C of o
Permit Description: TH: TD#16-65-37 T06-M0067
Start Date Submittal Complete Date Status  
04/19/2006 RESIDENTIAL BLDG-MODEL PLAN/ENGINE/WALK THRU 04/19/2006 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T06CM02256
Permit Status: C of o
Permit Description: TH: TD#16-65-37 T06-M0067
Total Outstanding Activity Conditions - 1
Date Name
04/19/2006 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: C of o
Permit Number: T06CM02256
Permit Description: TH: TD#16-65-37 T06-M0067
Total Completed Inspections - 34
Date Description Inspector Results Comments
05/01/2006 PLUMBING - ROUGH, SOIL RMYERS Approved IVRS - Inspection :*
1. ABS DWV UNDERSLAB OK TO COVER
INSTALLED DUAL ROUGH
05/09/2006 BUILDING PRE-SLAB JBURGE Approved IVRS - Inspection :*
05/09/2006 EXCAVATION/LAYOUT REBAR & ZON JBURGE Approved IVRS - Inspection :*
05/16/2006 ELECTRIC - UFER RSUBA Approved IVRS - Inspection :
See detailed listing on site.| 999*
11/13/2006 EXT METAL CLIPS/EXT SHEATHING AQUIROZ Approved IVRS - Inspection :*
11/15/2006 MECHANICAL - INTERMEDIATE JMILITEL Approved IVRS - Inspection :*
PROVIDE BACKING AROUND ALL CEILING BOXES PRIOR TO SHEETROCK.
11/21/2006 PLUMBING - INTERMEDIATE RMYERS Approved IVRS - Inspection :*
OK TO COVER ALL AREAS
12/04/2006 ROOF NAILING LHANLY Approved IVRS - Inspection :*
12/08/2006 ELECTRIC - INTERMEDIATE CCLEMENS Approved IVRS - Inspection :*
STILL NEED RECEPTACLE @ MASTER BEDROOM BY DOOR

OK INTERIOR ELECTRICAL COVER AFTER CORRECTION
12/11/2006 FRAMING AQUIROZ Approved IVRS - Inspection :*
12/20/2006 STUCCO MESH AQUIROZ Approved IVRS - Inspection :*
EXCLUDES GARAGE FRONTS
12/29/2006 SHEET ROCK NAILING AQUIROZ Approved IVRS - Inspection :*
03/22/2007 TEP CLEARANCE - AM JWEATHER Approved TEC CLEARED PER C. CLEMENS
04/02/2007 PLUMBING - YARD WTR LINE/TEST RMYERS Approved IVRS - Inspection :*
OK TO COVER
04/02/2007 PLUMBING - SEWER HCS CONNECT RMYERS Approved IVRS - Inspection :*
04/03/2007 ELECTRIC - CABLE DROP CCLEMENS Approved IVRS - Inspection :*
HUB BLANK SCREWS STILL NOT INSTALLED TOP OF SERVICE
06/05/2007 PLUMBING - PROGRESS BBENEDON Approved IVRS - Inspection :*
SHOWER PAN LINERS OK
06/20/2007 MECHANICAL - FINAL JMILITEL Approved IVRS - Inspection :*
06/21/2007 MECHANICAL - PROGRESS JMILITEL Approved
06/21/2007 MECHANICAL - ABOVE CEILING JMILITEL Approved
07/02/2007 ELECTRIC - FINAL CCLEMENS Approved IVRS - Inspection :*
07/03/2007 ELECTRIC - OUTDOOR LIGHTING CCLEMENS Approved
07/03/2007 OUTDOOR LIGHTING FINAL CCLEMENS Approved
07/03/2007 ELECTRIC - PROGRESS CCLEMENS Approved
07/03/2007 ELECTRIC - TEMPORARY SERVICE CCLEMENS Approved
07/03/2007 ELECTRIC - ABOVE CEILING CCLEMENS Approved
07/18/2007 PLUMBING - FINAL BBENEDON Approved IVRS - Inspection :*
KIT SINK DRAINS SLOW
07/19/2007 PLUMBING - GAS PRESSURE TEST BBENEDON Approved
07/19/2007 PLUMBING - GAS PRESS TEST FNL BBENEDON Approved
07/19/2007 PLUMBING - ABOVE CEILING BBENEDON Approved
08/07/2007 BUILDING - PROGRESS AQUIROZ Approved PER INSP COPY
08/07/2007 U VALUE FOR WINDOW AQUIROZ Approved PER INSP COPY
08/07/2007 BUILDING ABOVE CEILING AQUIROZ Approved PER INSP COPY
08/07/2007 BUILDING - FINAL AQUIROZ Approved PER INSP COPY