Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
C of o
Type:
SINGLE FAMILY NEW
Apply Date:
01/26/2006
Applicant:
T F ROBERTSON COMPANIES
Description:
TOWNHOUSE:MODEL

Permit Reviews

Permit Number - T06CM00584
Permit Status: C of o
Permit Description: TOWNHOUSE:MODEL
Start Date Submittal Complete Date Status  
01/26/2006 RESIDENTIAL BLDG-MODEL PLAN/ENGINE/WALK THRU 01/26/2006 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T06CM00584
Permit Status: C of o
Permit Description: TOWNHOUSE:MODEL
Total Outstanding Activity Conditions - 1
Date Name
01/26/2006 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: C of o
Permit Number: T06CM00584
Permit Description: TOWNHOUSE:MODEL
Total Completed Inspections - 23
Date Description Inspector Results Comments
02/02/2006 ELECTRIC - UFER LHANLY Approved IVRS - Inspection :*
02/02/2006 BUILDING PRE-SLAB LHANLY Approved IVRS - Inspection :*
02/02/2006 EXCAVATION/LAYOUT REBAR & ZON LHANLY Approved IVRS - Inspection :*
02/24/2006 REINFORCED MASONRY PRE-GROUT LHANLY Approved IVRS - Inspection :*
02/24/2006 ROOF NAILING LHANLY Approved IVRS - Inspection :*
02/24/2006 EXT METAL CLIPS/EXT SHEATHING LHANLY Approved IVRS - Inspection :*
04/11/2006 U VALUE FOR WINDOW LHANLY Approved IVRS - Inspection :*
04/11/2006 STUCCO MESH LHANLY Approved IVRS - Inspection :*
04/11/2006 FRAMING LHANLY Approved IVRS - Inspection :*
04/14/2006 ELECTRIC - CABLE DROP DSANTACR Approved IVRS - Inspection :*
04/14/2006 ELECTRIC - INTERMEDIATE DSANTACR Approved IVRS - Inspection :*
04/17/2006 TEP CLEARANCE - AM JWEATHER Approved TEC CLEARED PER D. SANTACRUZ
04/18/2006 MECHANICAL - INTERMEDIATE CWILLIAM Approved IVRS - Inspection :*
05/02/2006 PLUMBING - INTERMEDIATE BBENEDON Approved YARD WATER REQUIRED TO HAVE CLEAN COMPACTABLE DIRT.
ALL CLOTHES DRYERS ARE REQUIRED TO BE ELEVATED 18" ABOVE THE FLOOR IN A GARAGE.
I RECOMMEND THAT YOU RAISE YOUR GAS VALVE AND DRYER VENT BOX TO AVOID PROBLEMS INSTALLING DRYER.
DRYERS NOT ELEVATED IN A GARAGE MAY RESULT IN DEATH, EXPLOSION OR FIRE.
06/09/2006 MECHANICAL - FINAL CWILLIAM Approved IVRS - Inspection :*
06/14/2006 PLUMBING - ROUGH, SOIL LHANLY Approved IVRS - Inspection :*
06/14/2006 SHEET ROCK NAILING LHANLY Approved IVRS - Inspection :*
06/15/2006 ELECTRIC - FINAL DSANTACR Approved IVRS - Inspection :*
06/15/2006 PLUMBING - FINAL BBENEDON Approved IVRS - Inspection :*
06/15/2006 PLUMBING - GAS PRESSURE TEST BBENEDON Approved IVRS - Inspection :*
06/16/2006 BUILDING - FINAL AALEGRIA Approved IVRS - Inspection :*
06/19/2006 PERMIT FINALED BFLORES Approved
06/19/2006 ELECTRIC - UNDERGROUND DSANTACR Approved

Documents

File Name Document Type  
C OF O_07-21-2006.TIF CERT OF OCC VIEW
None DOCUMENTS VIEW