Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Closed
Type:
COMMERCIAL OTHER
Address:
308 W GLENN ST
Address NEW:
308 W GLENN ST
Apply Date:
01/25/2006
Applicant:
RICK ENGINEERING
Description:
GRADING CUT 6300 FILL 6000
Contractors:
  • DIVERSIFED DESIGN AND CONSTRUCTION RESIDENTIAL I

Permit Reviews

Permit Number - T06BU00192
Permit Status: Closed
Permit Description: GRADING CUT 6300 FILL 6000
Start Date Submittal Complete Date Status  
01/25/2006 PLANS OK TO SUBMIT - GRADING 01/25/2006 COMPLETED Review Details
01/25/2006 GRADING 03/20/2006 COMPLETED Review Details
02/28/2007 GRADING 03/16/2007 COMPLETED Review Details
05/26/2009 REVISION - GRADING 06/09/2009 COMPLETED Review Details
09/25/2008 REVISION - GRADING 10/13/2008 COMPLETED Review Details
10/03/2007 REVISION - GRADING 10/16/2007 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T06BU00192
Permit Status: Closed
Permit Description: GRADING CUT 6300 FILL 6000
Total Outstanding Activity Conditions - 2
Date Name
01/25/2006 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.
03/01/2007 LANDSCAPE INSPECTION REQUIRED.

Completed Inspections

Permit Status: Closed
Permit Number: T06BU00192
Permit Description: GRADING CUT 6300 FILL 6000
Total Completed Inspections - 8
Date Description Inspector Results Comments
07/19/2007 STORMWATER INSTALL OF CONTROLS MRUSSO Approved 1) RE-INSTALL SILT FENCE ALONG NE CORNER OF SITE/OR ADD ROCK TO AREA AND USE AS ENTRANCE. - AREA BEING USED FOR CONSTRUCTION ENTRANCE.
2) SWEEP UP TRACKED MATERIAL OFF OF BALBOA.
3) ENSURE A DESIGNATED CONCRETE WASH OUT IS INSTALLED AS SOON AS PRACTICABLE.
4) ENSURE ROUTINE STORM WATER MAINT. SELF INSPECTIONS ARE PERFORMED AND DOCUMENTED.
5) POST A SIGNED COPY OF YOUR NOI ON SITE.
6) CONTINUE TO MAINTAIN SEDIMENT CONTROLS AS NEEDED UNTIL THE SITE IS 100% STABILIZED.
07/19/2007 ENGINEERING PRE-CONSTRUCTION MRUSSO Approved 1) RE-INSTALL SILT FENCE ALONG NE CORNER OF SITE/OR ADD ROCK TO AREA AND USE AS ENTRANCE. - AREA BEING USED FOR CONSTRUCTION ENTRANCE.
2) SWEEP UP TRACKED MATERIAL OFF OF BALBOA.
3) ENSURE A DESIGNATED CONCRETE WASH OUT IS INSTALLED AS SOON AS PRACTICABLE.
4) ENSURE ROUTINE STORM WATER MAINT. SELF INSPECTIONS ARE PERFORMED AND DOCUMENTED.
5) POST A SIGNED COPY OF YOUR NOI ON SITE.
6) CONTINUE TO MAINTAIN SEDIMENT CONTROLS AS NEEDED UNTIL THE SITE IS 100% STABILIZED.
11/01/2007 GRADING - INTERMEDIATE MRUSSO Approved ANY SIGNIFICANT CHANGES MADE TO THE APPROVED GRADING PLAN MUST BE SUBMITTED BY THE ENGINEER OF RECORD AND APPROVED BY THE CITY OF TUCSON.

PROVIDE A DRAINAGE CERTIFICATION STATEMNET FRON THE ENGINEER OF RECORD PRIOR TO FINAL GARDING APPROVAL

APPROVAL FOR A C OF O FOR ENGINEERING WILL NOT BE GIVEN UNTIL THE FINAL GRADING INSPECTION IS APPROVED.
11/20/2007 STORMWATER FOLLOW-UP INSP MRUSSO Approved
11/20/2007 STORMWATER FOLLOW-UP INSP MRUSSO Approved ALL ITEMS HAVE BEEN ADDRESSED, NO ADDITIONAL STORM WATER CONCERNS AT THIS TIME
07/17/2008 GRADING - FINAL MRUSSO Approved 1) CLEAN OUT BUBBLER CATCH BASIN (SEE NOTE #18 - DETAIL 0/5) SHOWN ON APPROVED GRADING PLAN.
2) INSTALL ROCK RIP RAP PAD AT OUTLET OF BUBBLER, NW CORNER.
3) COMPLETE INSTALLATION OF RAILING ALONG RET/DET BASIN AT NE CORNER.
4) PATCH ASPHALT AT CURBING ALONG PUBLIC ROADWAYS ON NE CORNER.
5) CLEAN OUT - 8" OUTLET PIPE OF RET/DET BASIN.
6) REPAIR EROSION DAMAGE FROM ROOF DRAINS LOCATED ON EAST SIDE OF LOADING DOCK AREA - INSTALL SPLASH PADS
7) PROVIDE AN APPROVED DRAWING SHAOWING CHANGES MADE TO VAN DROP OFF AREA SEE NOTES #6 AND #7 ON APPROVED GRADING PLAN
8) ENSURE BOTTOM WIDTH OF RET/DET BASIN NORTH OF CULVERT CROSSING IS 11' ACCROSS.
.........TO BE CONTINUED
02/23/2009 STORMWATER FINAL INSPECTION MRUSSO Approved
03/24/2011 LANDSCAPE INSPECTION ACONNOR Approved

Documents

File Name Document Type  
REVISION_001.TIF GRADING PLANS VIEW
APPROVED_02.TIF GRADING PLANS VIEW
APPROVED_03.TIF GRADING PLANS VIEW
APPROVED_04.TIF GRADING PLANS VIEW
APPROVED_05.TIF GRADING PLANS VIEW
None DOCUMENTS VIEW
T06BU00192.PDF DOCUMENTS VIEW