Permit: T05PL01752
Permit Details
Status:
Expired
Type:
SINGLE FAMILY OTHER
Address:
4763 S GOLDENROD DR
Address NEW:
4763 S GOLDENROD DR
Apply Date:
10/31/2005
Applicant:
ADAMS SAMUEL L
Description:
GAS LINE:NEW
Permit Reviews
Permit Number - T05PL01752
Permit Status: Expired
Permit Description: GAS LINE:NEW
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 10/31/2005 | PLUMBING | 10/31/2005 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T05PL01752
Permit Status: Expired
Permit Description: GAS LINE:NEW
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 10/31/2005 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T05PL01752
Permite Description: GAS LINE:NEW
Total Outstanding Inspections - 1
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/07/2005 | PLUMBING - FINAL | N/A | Not ready for Inspection | IVRS - Inspection :* 1) VENT FROM WATER HEATER TO BE 3' ABOVE TOP OF COOLER INTAKE WHEN WITHIN 10' 2) VENT FROM FURNACE TO BE 2' ABOVE TOP OF COOLER INTAKE WHEN WITHIN 10' 3) PROVIDE BONDING AT WATER HEATER CLOSET 4) PROVIDE 90 DEGREE DOWN AND DRYWALL AT T & P TERMINATION |
Completed Inspections
Permit Status: Expired
Permit Number: T05PL01752
Permit Description: GAS LINE:NEW
Total Completed Inspections - 1
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/07/2005 | PLUMBING - GAS PRESSURE TEST | RRICH | Approved | IVRS - Inspection :* 1) 15 PSI TEST FROM METER TO WATER HEATER AND FURNACE 2) GAS CARD AT METER |