Permit: T05PL01752

Parcel: 136382740


Addresses:

4763 S GOLDENROD DR

Inspection Status: Not ready for Inspection

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
11/07/2005 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1) VENT FROM WATER HEATER TO BE 3' ABOVE TOP OF COOLER INTAKE WHEN WITHIN 10'
2) VENT FROM FURNACE TO BE 2' ABOVE TOP OF COOLER INTAKE WHEN WITHIN 10'
3) PROVIDE BONDING AT WATER HEATER CLOSET
4) PROVIDE 90 DEGREE DOWN AND DRYWALL AT T & P TERMINATION
11/01/2005 PLUMBING - FINAL Denied IVRS - Inspection :
There is no access to the site.| 920*PLEASE SCHEDULE AN INSPECTION WHEN SOMEONE WILL BE HOME