Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Permit Details

Status:
Final
Type:
DUPLEX NEW
Address NEW:
4084 N 1ST AV #01
Apply Date:
12/27/2005
Applicant:
DAVID BLAIR
Description:
DUPLEX TD # 16-53-17
Contractors:
  • BOULDER CANYON BUILDERS INC ,

Permit Reviews

Permit Number - T05CM06452
Permit Status: Final
Permit Description: DUPLEX TD # 16-53-17
Start Date Submittal Complete Date Status  
12/27/2005 RESIDENTIAL BLDG-MODEL PLAN/ENGINE/WALK THRU 12/28/2005 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T05CM06452
Permit Status: Final
Permit Description: DUPLEX TD # 16-53-17
Total Outstanding Activity Conditions - 1
Date Name
12/27/2005 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: Final
Permit Number: T05CM06452
Permit Description: DUPLEX TD # 16-53-17
Total Completed Inspections - 29
Date Description Inspector Results Comments
01/20/2006 SITE - SEWER RMYERS Approved IVRS - Inspection :*
1. 4" SEWER FROM TAP AT MAIN INCLUDING DIRECTIONAL CLEAN OUT AT P.L AND ALL THE WAY TO WITHIN TEN FEET FROM THE BLDG 3 PLACES - OK
2. GREEN TRACER WIRE INSTALLED PER H.B. 2256 AND PCWWM DETAIL #4
3. OK TO COVER
01/20/2006 SITE - SEWER RMYERS Approved IVRS - Inspection :*EXCEPT FOR THE TWO WAY CLEAN OUT, WHERE THE BLDG. DRAIN & BLDG. SEWER CONNECT, CLEAN OUTS SHALL OPEN IN THE DIRECTION OF FLOW. CLEAN OUTS ARE REQUIRED WHEN YOU EXCEED ONE HUNDRED FEET, AND HWN YOU EXCEED 135 DEGREE CHANGE OF DIRECTION. A DIRECTIONAL CLEAN OUT IS REQUIRED AT THE PROPERTY LINE-PER PCWWM DETAIL 104. TRACER WIRE IS REQUIRED PER DETAIL 104 PCWWM AND HOUSE BILL 2256
01/25/2006 PLUMBING - SEWER HCS CONNECT RMYERS Approved IVRS - Inspection :*
1. SEWER APPROVED ON 12/06
2. UNDERGROUND NOT INSTALLED PER PLAN
NO REDLINES ON SITE
INSTALL PER PLAN OR REVISE PLAN
01/26/2006 PLUMBING - ROUGH, SOIL RMYERS Approved IVRS - Inspection :*
1) CORRECTION MADE OK
2) ROUGH SOIL OK TO COVER
3) RED LINES ON SITE
02/06/2006 ELECTRIC - UFER CCLEMENS Approved IVRS - Inspection :*
02/14/2006 BUILDING PRE-SLAB AQUIROZ Approved IVRS - Inspection :*
02/14/2006 EXCAVATION/LAYOUT REBAR & ZON AQUIROZ Approved IVRS - Inspection :*
03/20/2006 EXT METAL CLIPS/EXT SHEATHING AQUIROZ Approved IVRS - Inspection :*
03/21/2006 ROOF NAILING AQUIROZ Approved IVRS - Inspection :*
04/07/2006 ELECTRIC - CABLE DROP CCLEMENS Approved IVRS - Inspection :*
1) DRIVE GROUND RODS
04/07/2006 ELECTRIC - TEMPORARY SERVICE CCLEMENS Approved
04/13/2006 PLUMBING - YARD WTR LINE/TEST RMYERS Approved IVRS - Inspection :*
OK TO COVER
04/26/2006 FRAMING AQUIROZ Approved IVRS - Inspection :*
04/27/2006 MECHANICAL - INTERMEDIATE JMILITEL Approved OK FOR SHEETROCK
1ST FLOOR BACKDRAFT DAMPER MISSING IN EXHAUST FAN
2ND FLOOR DAMPER STUCK
WILL CHECK ON FINAL.
04/27/2006 PLUMBING - INTERMEDIATE RMYERS Approved 1. PVC DWV THRU ROOF OK
2. PEX OK
3. TUBS OK
4. CLOSET FLANGES OK
OK TO COVER ALL AREAS
05/10/2006 SHEET ROCK NAILING AQUIROZ Approved IVRS - Inspection :*
05/12/2006 STUCCO MESH AQUIROZ Approved IVRS - Inspection :*
06/30/2006 TEP CLEARANCE - AM JWEATHER Approved ECO CLEARED FOR UNIT #2 PER C. CLEMENS
07/20/2006 PLUMBING - FINAL RMYERS Approved IVRS - Inspection :*
PLUMBING FINAL OK
OK FOR C OF O S.T.O.I
07/20/2006 MECHANICAL - FINAL CWILLIAM Approved IVRS - Inspection :*
07/23/2006 OUTDOOR LIGHTING FINAL RHOLLAND Approved IVRS - Inspection :*
07/23/2006 ELECTRIC - FINAL RHOLLAND Approved IVRS - Inspection :*
07/23/2006 ELECTRIC - OUTDOOR LIGHTING RHOLLAND Approved IVRS - Inspection :*
07/23/2006 ELECTRIC - INTERMEDIATE RHOLLAND Approved IVRS - Inspection :*
07/23/2006 ELECTRIC - UNDERGROUND RHOLLAND Approved IVRS - Inspection :*
07/25/2006 BUILDING - FINAL AQUIROZ Approved IVRS - Inspection :*
07/25/2006 U VALUE FOR WINDOW AQUIROZ Approved IVRS - Inspection :*
07/25/2006 STEM WALL/RETAINING WALL AQUIROZ Approved IVRS - Inspection :*
07/26/2006 PERMIT FINALED BFLORES Approved