Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Final
Type:
DUPLEX NEW
Apply Date:
12/27/2005
Applicant:
DAVID BLAIR
Description:
DUPLEX TD # 16-53-17
Contractors:
  • BOULDER CANYON BUILDERS INC ,

Permit Reviews

Permit Number - T05CM06452
Permit Status: Final
Permit Description: DUPLEX TD # 16-53-17
Start Date Submittal Complete Date Status  
12/27/2005 RESIDENTIAL BLDG-MODEL PLAN/ENGINE/WALK THRU 12/28/2005 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T05CM06452
Permit Status: Final
Permit Description: DUPLEX TD # 16-53-17
Total Outstanding Activity Conditions - 1
Date Name
12/27/2005 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: Final
Permit Number: T05CM06452
Permit Description: DUPLEX TD # 16-53-17
Total Completed Inspections - 29
Date Description Inspector Results Comments
01/20/2006 SITE - SEWER RMYERS Approved IVRS - Inspection :*
1. 4" SEWER FROM TAP AT MAIN INCLUDING DIRECTIONAL CLEAN OUT AT P.L AND ALL THE WAY TO WITHIN TEN FEET FROM THE BLDG 3 PLACES - OK
2. GREEN TRACER WIRE INSTALLED PER H.B. 2256 AND PCWWM DETAIL #4
3. OK TO COVER
01/20/2006 SITE - SEWER RMYERS Approved IVRS - Inspection :*EXCEPT FOR THE TWO WAY CLEAN OUT, WHERE THE BLDG. DRAIN & BLDG. SEWER CONNECT, CLEAN OUTS SHALL OPEN IN THE DIRECTION OF FLOW. CLEAN OUTS ARE REQUIRED WHEN YOU EXCEED ONE HUNDRED FEET, AND HWN YOU EXCEED 135 DEGREE CHANGE OF DIRECTION. A DIRECTIONAL CLEAN OUT IS REQUIRED AT THE PROPERTY LINE-PER PCWWM DETAIL 104. TRACER WIRE IS REQUIRED PER DETAIL 104 PCWWM AND HOUSE BILL 2256
01/25/2006 PLUMBING - SEWER HCS CONNECT RMYERS Approved IVRS - Inspection :*
1. SEWER APPROVED ON 12/06
2. UNDERGROUND NOT INSTALLED PER PLAN
NO REDLINES ON SITE
INSTALL PER PLAN OR REVISE PLAN
01/26/2006 PLUMBING - ROUGH, SOIL RMYERS Approved IVRS - Inspection :*
1) CORRECTION MADE OK
2) ROUGH SOIL OK TO COVER
3) RED LINES ON SITE
02/06/2006 ELECTRIC - UFER CCLEMENS Approved IVRS - Inspection :*
02/14/2006 BUILDING PRE-SLAB AQUIROZ Approved IVRS - Inspection :*
02/14/2006 EXCAVATION/LAYOUT REBAR & ZON AQUIROZ Approved IVRS - Inspection :*
03/20/2006 EXT METAL CLIPS/EXT SHEATHING AQUIROZ Approved IVRS - Inspection :*
03/21/2006 ROOF NAILING AQUIROZ Approved IVRS - Inspection :*
04/07/2006 ELECTRIC - CABLE DROP CCLEMENS Approved IVRS - Inspection :*
1) DRIVE GROUND RODS
04/07/2006 ELECTRIC - TEMPORARY SERVICE CCLEMENS Approved
04/13/2006 PLUMBING - YARD WTR LINE/TEST RMYERS Approved IVRS - Inspection :*
OK TO COVER
04/26/2006 FRAMING AQUIROZ Approved IVRS - Inspection :*
04/27/2006 MECHANICAL - INTERMEDIATE JMILITEL Approved OK FOR SHEETROCK
1ST FLOOR BACKDRAFT DAMPER MISSING IN EXHAUST FAN
2ND FLOOR DAMPER STUCK
WILL CHECK ON FINAL.
04/27/2006 PLUMBING - INTERMEDIATE RMYERS Approved 1. PVC DWV THRU ROOF OK
2. PEX OK
3. TUBS OK
4. CLOSET FLANGES OK
OK TO COVER ALL AREAS
05/10/2006 SHEET ROCK NAILING AQUIROZ Approved IVRS - Inspection :*
05/12/2006 STUCCO MESH AQUIROZ Approved IVRS - Inspection :*
06/30/2006 TEP CLEARANCE - AM JWEATHER Approved ECO CLEARED FOR UNIT #2 PER C. CLEMENS
07/20/2006 PLUMBING - FINAL RMYERS Approved IVRS - Inspection :*
PLUMBING FINAL OK
OK FOR C OF O S.T.O.I
07/20/2006 MECHANICAL - FINAL CWILLIAM Approved IVRS - Inspection :*
07/23/2006 OUTDOOR LIGHTING FINAL RHOLLAND Approved IVRS - Inspection :*
07/23/2006 ELECTRIC - FINAL RHOLLAND Approved IVRS - Inspection :*
07/23/2006 ELECTRIC - OUTDOOR LIGHTING RHOLLAND Approved IVRS - Inspection :*
07/23/2006 ELECTRIC - INTERMEDIATE RHOLLAND Approved IVRS - Inspection :*
07/23/2006 ELECTRIC - UNDERGROUND RHOLLAND Approved IVRS - Inspection :*
07/25/2006 BUILDING - FINAL AQUIROZ Approved IVRS - Inspection :*
07/25/2006 U VALUE FOR WINDOW AQUIROZ Approved IVRS - Inspection :*
07/25/2006 STEM WALL/RETAINING WALL AQUIROZ Approved IVRS - Inspection :*
07/26/2006 PERMIT FINALED BFLORES Approved