Permit: T05CM05375
Permit Details
Apply Date:
10/21/2005
Applicant:
DESIGN RESULTS
Description:
NEW COMMERCIAL WAREHOUSE
Architects:
- FENECK, JOHN
Contractors:
- KOBY GALLAGHER CONSTRUCTION INC
Permit Reviews
Permit Number - T05CM05375
Permit Status: C of o
Permit Description: NEW COMMERCIAL WAREHOUSE
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 01/19/2007 | 3RD PARTY REVIEW-REVISION/OTHER | 01/19/2007 | COMPLETED |
| 10/21/2005 | PLANS OK TO SUBMIT - 3RD PARTY | 10/21/2005 | COMPLETED |
| 10/21/2005 | PLANS OK TO SUBMIT - SITE | 10/21/2005 | COMPLETED |
| 10/21/2005 | 3RD PARTY REVIEW-COMMERCIAL | 11/30/2005 | COMPLETED |
| 10/21/2005 | SITE | 12/15/2005 | COMPLETED |
| 10/21/2005 | POST 3RD PARTY REVIEW | 01/12/2006 | COMPLETED |
| 12/15/2005 | RESUBMITTAL - SITE | 02/22/2006 | COMPLETED |
| 12/19/2005 | POST 3RD PARTY REVIEW | 02/22/2006 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T05CM05375
Permit Status: C of o
Permit Description: NEW COMMERCIAL WAREHOUSE
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 10/21/2005 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T05CM05375
Permit Description: NEW COMMERCIAL WAREHOUSE
Total Completed Inspections - 33
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/21/2006 | PLUMBING - ROUGH, SOIL | BBENEDON | Approved | IVRS - Inspection :* |
| 05/26/2006 | EXCAVATION/LAYOUT REBAR & ZON | AALEGRIA | Approved | IVRS - Inspection :* |
| 09/12/2006 | REINFORCED MASONRY PRE-GROUT | AALEGRIA | Approved | IN COMPLIANCE WITH APPROVED PLAN SHEET S-1 8" CMU 2 #4 ON BOND BEAM AND OVERLAP 24" FOR #4 TOPOUT. |
| 11/17/2006 | BUILDING PRE-SLAB | AALEGRIA | Approved | IVRS - Inspection : See detailed listing on site.| 999* 1. PROVIDE EXPANSION CONTROL JOINT ACCORDING WITH APPROVED PLANS ON SHEET S-1 JOINTS 1/8" X 1 1/4" DEEP 2. PROVIDE INFORMATION OR APPROVAL FOR BUILDING PRE-SLAB INSPECTION W/6X6 - W.4XW14 WWF OR FIBERMESH AT OPTION. |
| 11/17/2006 | ELECTRIC - UFER | DSANTACR | Approved | IVRS - Inspection : See detailed listing on site.| 999* SEE NOTES LAST INSPECTION |
| 12/22/2006 | U VALUE FOR WINDOW | LHANLY | Approved | IVRS - Inspection :* |
| 12/22/2006 | BUILDING ABOVE CEILING | LHANLY | Approved | IVRS - Inspection :* |
| 12/22/2006 | FRAMING | LHANLY | Approved | IVRS - Inspection :* |
| 12/22/2006 | ROOF NAILING | LHANLY | Approved | IVRS - Inspection :* |
| 12/28/2006 | PLUMBING - INTERMEDIATE | RRICH | Approved | IVRS - Inspection :* 1) WATER TEST WASTE AND VENT THRU ROOF OK 2) PROVIDE TEST ON WATER PIPING 3) PROVIDE FHA STRAPS TO PROTECT DWV AT FLOOR COVER 4) SHALL PROVIDE REVISED CITY APPROVED PLAN FOR CHANGE FROM WATER HEATER TO INSTA HOT WATER HEATER 5) NOTE: INFORMED OWNER ABOUT RESTROOM ISSUE, THIS IS BEING HANDLED BY BLDG OFFICIAL |
| 12/28/2006 | PLUMBING - ABOVE CEILING | RRICH | Approved | IVRS - Inspection :* |
| 01/30/2007 | MECHANICAL - INTERMEDIATE | JMILITEL | Approved | IVRS - Inspection :* |
| 01/30/2007 | ELECTRIC - OUTDOOR LIGHTING | RMAJUTA | Approved | IVRS - Inspection :* |
| 01/30/2007 | ELECTRIC - ABOVE CEILING | RMAJUTA | Approved | IVRS - Inspection :* |
| 01/30/2007 | ELECTRIC - INTERMEDIATE | RMAJUTA | Approved | IVRS - Inspection :* |
| 02/05/2007 | PLUMBING - SEWER HCS CONNECT | RLEDONNE | Approved | IVRS - Inspection :* |
| 02/07/2007 | MECHANICAL - FINAL | JMILITEL | Approved | IVRS - Inspection :* |
| 02/23/2007 | ELECTRIC - CABLE DROP | DSANTACR | Approved | IVRS - Inspection :* 1) PROVIDE LETTER FOR SERVICE MOD'S NEXT INSPECTION |
| 02/23/2007 | PLUMBING - YARD WTR LINE/TEST | RLEDONNE | Approved | IVRS - Inspection :* |
| 02/26/2007 | TEP CLEARANCE - AM | JWEATHER | Approved | TEC CLEARED PER D. SANTACRUZ |
| 03/12/2007 | MECHANICAL - ABOVE CEILING | IVR USER | Approved | IVRS - AP canceled |
| 03/26/2007 | OUTDOOR LIGHTING FINAL | DSANTACR | Approved | IVRS - Inspection :* |
| 04/04/2007 | SHEET ROCK NAILING | AALEGRIA | Approved | IVRS - Inspection :* |
| 04/04/2007 | ELECTRIC - FINAL | DSANTACR | Approved | IVRS - Inspection :* |
| 04/11/2007 | BUILDING - FINAL | AALEGRIA | Approved | IVRS - Inspection :* BUILDING AND SITE IN COMPLIANCE WITH APPROVED PLAN AND SPECIFICATION AND SEC 109.3.10 REGARDING BUILDING FINAL. |
| 04/12/2007 | PLUMBING - FINAL | RLEDONNE | Approved | IVRS - Inspection :* |
| 04/12/2007 | SIGN - FINAL | JYBARRA | Approved | IVRS - Inspection :* |
| 04/12/2007 | RIGHT OF WAY - FINAL | LLOPEZ | Approved | PER EMAIL |
| 04/18/2007 | NPPO - FINAL | ACONNOR | Approved | |
| 04/18/2007 | LANDSCAPE - FINAL | ACONNOR | Approved | |
| 04/19/2007 | PERMIT FINALED | LJACKSON | Approved | |
| 04/19/2007 | ENGINEERING - FINAL | MAVERY | Approved | |
| 04/19/2007 | FIRE - FINAL | CSCHULTZ | Approved |