Permit: T05CM05375

Parcel: 129134240


Addresses:

925 E 36TH ST

Inspection Status: Approved

Inspection History: BUILDING PRE-SLAB

Date Description Inspector Results Comments
04/04/2007 BUILDING PRE-SLAB Approved IVRS - Inspection :*
11/17/2006 BUILDING PRE-SLAB Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. PROVIDE EXPANSION CONTROL JOINT ACCORDING WITH APPROVED PLANS ON SHEET S-1 JOINTS 1/8" X 1 1/4" DEEP
2. PROVIDE INFORMATION OR APPROVAL FOR BUILDING PRE-SLAB INSPECTION W/6X6 - W.4XW14 WWF OR FIBERMESH AT OPTION.
05/25/2006 BUILDING PRE-SLAB Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. UNDERGROUND/PLUMBING ROUGH - SOIL
NEED TO BE INSPECTED.
2. REBAR ON NORTH FOOTING F2 NEED TO BE AT LEAST 3 1/2" CLEAR ABOVE GROUND.
3. PROVIDE 45 DEGREE ANGLE ON ALL FOOTING AND REMOVE EXTRA SOIL (PROVIDE CLEAN FOUNDATION).
4. PROVIDE VERTICAL REBAR ON WEST AND COMPLETE FORMS
5. WRAP SEWER LINES (FOAM PROTECTION).