Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T05CM02798
Permit Details
Apply Date:
06/17/2005
Applicant:
LANG CONSTRUCTION INC , W J
Description:
ADDITION: DENTAL OFFICE
Contractors:
- LANG CONSTRUCTION INC , W J
Permit Reviews
Permit Number - T05CM02798
Permit Status: C of o
Permit Description: ADDITION: DENTAL OFFICE
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
06/17/2005 | PLANS OK TO SUBMIT - 3RD PARTY | 06/20/2005 | COMPLETED |
06/17/2005 | PLANS OK TO SUBMIT - SITE | 06/20/2005 | COMPLETED |
06/20/2005 | SITE | 07/13/2005 | COMPLETED |
06/20/2005 | 3RD PARTY REVIEW-COMMERCIAL | 08/16/2005 | COMPLETED |
08/08/2005 | RESUBMITTAL - SITE | 08/25/2005 | COMPLETED |
08/16/2005 | POST 3RD PARTY REVIEW | 08/25/2005 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T05CM02798
Permit Status: C of o
Permit Description: ADDITION: DENTAL OFFICE
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
06/17/2005 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T05CM02798
Permit Description: ADDITION: DENTAL OFFICE
Total Completed Inspections - 30
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/01/2005 | EXCAVATION/LAYOUT REBAR & ZON | LHANLY | Approved | IVRS - Inspection :* STEEL AND FOOTING SIZE OK OK TO POUR IT IS REQUIRED THAT ALL SPECIAL INSPECTION FIELD REPORTS BE ON SITE |
09/08/2005 | PLUMBING - ROUGH, SOIL | TRINIVJR | Approved | IVRS - Inspection :* 1) SOIL WATER TEST IS OK 2) RWL AT SOUTH EAST CORNER OF BLDG IS OK 3) NOTE: BLDG DRAIN IS STUBBED OUT OF BLDG 2' ONLY 4) OK TO BACKFILL TRENCH |
10/06/2005 | ROOF NAILING | LHANLY | Approved | IVRS - Inspection :* |
10/06/2005 | BUILDING PRE-SLAB | LHANLY | Approved | IVRS - Inspection :* |
10/10/2005 | EXT METAL CLIPS/EXT SHEATHING | LHANLY | Approved | IVRS - Inspection :* |
10/14/2005 | MECHANICAL - INTERMEDIATE | JMILITEL | Approved | IVRS - Inspection :* 1) OK FOR SHEETROCK 2) PROVIDE BACKING AROUND CEILING BOXES 3) DUCT LINER INSIDE BLDG ENVELOPE REQUIRED TO BE R-5 4) 1" LINER IS R4.2, 1/2" LINER R-2 5) PROVIDE ADEQUATE INSULATION 6) PLANS MAY HABE BEEN APPROVED IN ERROR 7) ITEM 04005 NOT APPLICABLE PER PAPERWORK TURNED IN BY INSPECTOR J. MILITELLO |
10/14/2005 | FRAMING | LHANLY | Approved | IVRS - Inspection :* |
10/15/2005 | PLUMBING - ABOVE CEILING | TRINIVJR | Approved | IVRS - Inspection :* |
10/20/2005 | PLUMBING - INTERMEDIATE | TRINIVJR | Approved | IVRS - Inspection :*ALL CORRECTIONS HAVE BEEN MADE INSULATION OF HOT WATER SYSTEM IS OK OK FOR DRY WALL. |
10/25/2005 | STUCCO MESH | LHANLY | Approved | IVRS - Inspection :* |
10/27/2005 | SHEET ROCK NAILING | LHANLY | Approved | IVRS - Inspection :* |
11/09/2005 | PLUMBING - SEWER HCS CONNECT | TRINIVJR | Approved | IVRS - Inspection :*HCS SEWER MAIN TAP IS OK HCS CONNECTION IS OK SOIL WATER TEST IS OK OK TO BACKFILL TRENCH |
11/12/2005 | PLUMBING - YARD WTR LINE/TEST | TRINIVJR | Approved | IVRS - Inspection :*YARD WATER LINE FROM 3" EXSISTING C.W. SUPPLY TO BLDG SERVICE IS OK OK TO BACKFILL TRENCH. |
11/16/2005 | MECHANICAL - ABOVE CEILING | JMILITEL | Approved | IVRS - Inspection :*STRAP FLEX DUCT UP OFF OF CEILING GRID & TILES DO NOT USE T-BAR WIRE TO STRAP FLEX DUCT ELEC. CONDUITS NOT TO BE USED AS DUCT SUPPORT. WILL CHECK ON FINAL. OK FOR CEILING TILES |
11/16/2005 | BUILDING ABOVE CEILING | JCAGLE | Approved | IVRS - Inspection :* |
11/18/2005 | MECHANICAL - PROGRESS | JMILITEL | Approved | IVRS - Inspection :* |
11/28/2005 | PLUMBING - PROGRESS | TRINIVJR | Approved | IVRS - Inspection :*DWV FOR HAND SINK THAT WAS RELOCATED IS OK HOT & COLD WATER DISTRIBUTION IS OK NOTE SHALL PROVIDE A BLIND PLUG FOR DELETED FIXTURE IN WALL |
11/29/2005 | BUILDING - PROGRESS | JCAGLE | Approved | IVRS - Inspection :*NEW STEEL ANGLE @ EXISTING OPENINGS FOR DOOR # 105B & HALL # 113 |
11/29/2005 | ELECTRIC - PROGRESS | RSUBA | Approved | IVRS - Inspection :*BREAKROOM RECEPTACLES # 109, # 111 |
12/15/2005 | ELECTRIC - SERVICE UPGRADE | RSUBA | Approved | |
12/15/2005 | ELECTRIC - FINAL | RSUBA | Approved | IVRS - Inspection :* |
12/15/2005 | ELECTRIC - ABOVE CEILING | RSUBA | Approved | IVRS - Inspection :* |
12/15/2005 | ELECTRIC - INTERMEDIATE | RSUBA | Approved | IVRS - Inspection :* |
12/15/2005 | ELECTRIC - UNDERGROUND | RSUBA | Approved | IVRS - Inspection :* |
12/22/2005 | MECHANICAL - FINAL | CWILLIAM | Approved | IVRS - Inspection :* |
12/26/2005 | PLUMBING - FINAL | TRINIVJR | Approved | IVRS - Inspection :*PLBG FINAL IS OK OK FOR C OF O |
12/27/2005 | FIRE - FINAL | LTHOMAS | Approved | |
12/27/2005 | BUILDING - FINAL | JCAGLE | Approved | IVRS - Inspection :* |
12/27/2005 | U VALUE FOR WINDOW | JCAGLE | Approved | IVRS - Inspection :* |
01/10/2006 | ENGINEERING - FINAL | DROBERTS | Approved | APPROVAL PER PHONE CALL |