Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
C of o
Type:
COMMERCIAL ADDITION
Apply Date:
06/17/2005
Applicant:
LANG CONSTRUCTION INC , W J
Description:
ADDITION: DENTAL OFFICE
Contractors:
  • LANG CONSTRUCTION INC , W J

Permit Reviews

Permit Number - T05CM02798
Permit Status: C of o
Permit Description: ADDITION: DENTAL OFFICE
Start Date Submittal Complete Date Status  
06/17/2005 PLANS OK TO SUBMIT - 3RD PARTY 06/20/2005 COMPLETED Review Details
06/17/2005 PLANS OK TO SUBMIT - SITE 06/20/2005 COMPLETED Review Details
06/20/2005 SITE 07/13/2005 COMPLETED Review Details
06/20/2005 3RD PARTY REVIEW-COMMERCIAL 08/16/2005 COMPLETED Review Details
08/08/2005 RESUBMITTAL - SITE 08/25/2005 COMPLETED Review Details
08/16/2005 POST 3RD PARTY REVIEW 08/25/2005 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T05CM02798
Permit Status: C of o
Permit Description: ADDITION: DENTAL OFFICE
Total Outstanding Activity Conditions - 1
Date Name
06/17/2005 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: C of o
Permit Number: T05CM02798
Permit Description: ADDITION: DENTAL OFFICE
Total Completed Inspections - 30
Date Description Inspector Results Comments
09/01/2005 EXCAVATION/LAYOUT REBAR & ZON LHANLY Approved IVRS - Inspection :*
STEEL AND FOOTING SIZE OK
OK TO POUR
IT IS REQUIRED THAT ALL SPECIAL INSPECTION FIELD REPORTS BE ON SITE
09/08/2005 PLUMBING - ROUGH, SOIL TRINIVJR Approved IVRS - Inspection :*
1) SOIL WATER TEST IS OK
2) RWL AT SOUTH EAST CORNER OF BLDG IS OK
3) NOTE: BLDG DRAIN IS STUBBED OUT OF BLDG 2' ONLY
4) OK TO BACKFILL TRENCH
10/06/2005 ROOF NAILING LHANLY Approved IVRS - Inspection :*
10/06/2005 BUILDING PRE-SLAB LHANLY Approved IVRS - Inspection :*
10/10/2005 EXT METAL CLIPS/EXT SHEATHING LHANLY Approved IVRS - Inspection :*
10/14/2005 MECHANICAL - INTERMEDIATE JMILITEL Approved IVRS - Inspection :*
1) OK FOR SHEETROCK
2) PROVIDE BACKING AROUND CEILING BOXES
3) DUCT LINER INSIDE BLDG ENVELOPE REQUIRED TO BE R-5
4) 1" LINER IS R4.2, 1/2" LINER R-2
5) PROVIDE ADEQUATE INSULATION
6) PLANS MAY HABE BEEN APPROVED IN ERROR
7) ITEM 04005 NOT APPLICABLE PER PAPERWORK TURNED IN BY INSPECTOR J. MILITELLO
10/14/2005 FRAMING LHANLY Approved IVRS - Inspection :*
10/15/2005 PLUMBING - ABOVE CEILING TRINIVJR Approved IVRS - Inspection :*
10/20/2005 PLUMBING - INTERMEDIATE TRINIVJR Approved IVRS - Inspection :*ALL CORRECTIONS HAVE BEEN MADE
INSULATION OF HOT WATER SYSTEM IS OK
OK FOR DRY WALL.
10/25/2005 STUCCO MESH LHANLY Approved IVRS - Inspection :*
10/27/2005 SHEET ROCK NAILING LHANLY Approved IVRS - Inspection :*
11/09/2005 PLUMBING - SEWER HCS CONNECT TRINIVJR Approved IVRS - Inspection :*HCS SEWER MAIN TAP IS OK
HCS CONNECTION IS OK
SOIL WATER TEST IS OK
OK TO BACKFILL TRENCH
11/12/2005 PLUMBING - YARD WTR LINE/TEST TRINIVJR Approved IVRS - Inspection :*YARD WATER LINE FROM 3" EXSISTING C.W. SUPPLY TO BLDG SERVICE IS OK
OK TO BACKFILL TRENCH.
11/16/2005 MECHANICAL - ABOVE CEILING JMILITEL Approved IVRS - Inspection :*STRAP FLEX DUCT UP OFF OF CEILING GRID & TILES
DO NOT USE T-BAR WIRE TO STRAP FLEX DUCT ELEC. CONDUITS NOT TO BE USED AS DUCT SUPPORT. WILL CHECK ON FINAL. OK FOR CEILING TILES
11/16/2005 BUILDING ABOVE CEILING JCAGLE Approved IVRS - Inspection :*
11/18/2005 MECHANICAL - PROGRESS JMILITEL Approved IVRS - Inspection :*
11/28/2005 PLUMBING - PROGRESS TRINIVJR Approved IVRS - Inspection :*DWV FOR HAND SINK THAT WAS RELOCATED IS OK
HOT & COLD WATER DISTRIBUTION IS OK
NOTE SHALL PROVIDE A BLIND PLUG FOR DELETED FIXTURE IN WALL
11/29/2005 BUILDING - PROGRESS JCAGLE Approved IVRS - Inspection :*NEW STEEL ANGLE @ EXISTING OPENINGS FOR DOOR # 105B & HALL # 113
11/29/2005 ELECTRIC - PROGRESS RSUBA Approved IVRS - Inspection :*BREAKROOM RECEPTACLES # 109, # 111
12/15/2005 ELECTRIC - SERVICE UPGRADE RSUBA Approved
12/15/2005 ELECTRIC - FINAL RSUBA Approved IVRS - Inspection :*
12/15/2005 ELECTRIC - ABOVE CEILING RSUBA Approved IVRS - Inspection :*
12/15/2005 ELECTRIC - INTERMEDIATE RSUBA Approved IVRS - Inspection :*
12/15/2005 ELECTRIC - UNDERGROUND RSUBA Approved IVRS - Inspection :*
12/22/2005 MECHANICAL - FINAL CWILLIAM Approved IVRS - Inspection :*
12/26/2005 PLUMBING - FINAL TRINIVJR Approved IVRS - Inspection :*PLBG FINAL IS OK
OK FOR C OF O
12/27/2005 FIRE - FINAL LTHOMAS Approved
12/27/2005 BUILDING - FINAL JCAGLE Approved IVRS - Inspection :*
12/27/2005 U VALUE FOR WINDOW JCAGLE Approved IVRS - Inspection :*
01/10/2006 ENGINEERING - FINAL DROBERTS Approved APPROVAL PER PHONE CALL

Documents

File Name Document Type  
C OF O_01-10-2006.TIF CERT OF OCC VIEW
None CERT OF OCC VIEW