SINGLE FAMILY ALTERATION
Address:
622 N 10TH AV
Apply Date:
06/14/2005
Applicant:
BOBBY OTERO
Description:
REMODEL FIRE DAMAGE:SFR

Permit Reviews

Permit Number - T05CM02744
Permit Status: Final
Permit Description: REMODEL FIRE DAMAGE:SFR
Start Date Submittal Complete Date Status  
05/04/2012 REVISION - - 5TH 08/08/2012 COMPLETED Review Details
05/25/2011 REVISION - - 3RD 05/25/2011 COMPLETED Review Details
06/14/2005 PLANS OK TO SUBMIT - RES 3RD PARTY 06/15/2005 COMPLETED Review Details
06/15/2005 3RD PARTY REVIEW-RESIDENTIAL 07/07/2005 COMPLETED Review Details
06/27/2013 REVISION - 10TH 06/27/2013 COMPLETED Review Details
07/07/2005 POST 3RD PARTY REVIEW 07/22/2005 COMPLETED Review Details
07/22/2005 RESUBMITTAL 07/22/2005 COMPLETED Review Details
08/08/2012 REVISION - - 6TH 08/08/2012 COMPLETED Review Details
08/21/2012 REVISION - - 6TH 08/21/2012 COMPLETED Review Details
08/29/2012 REVISION - - 7TH 08/29/2012 COMPLETED Review Details
09/11/2012 REVISION - - 8TH 09/12/2012 COMPLETED Review Details
09/16/2005 3RD PARTY REVIEW-REVISION/OTHER 09/16/2005 COMPLETED Review Details
10/03/2012 REVISION - - 9TH 11/08/2012 COMPLETED Review Details
10/05/2007 3RD PARTY REVIEW-REVISION/OTHER 10/05/2007 COMPLETED Review Details
11/07/2012 REVISION - WALK THRU 11/08/2012 COMPLETED Review Details
11/14/2011 REVISION - - 4TH 11/14/2011 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T05CM02744
Permit Status: Final
Permit Description: REMODEL FIRE DAMAGE:SFR
Total Outstanding Activity Conditions - 1
Date Name
06/14/2005 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: Final
Permit Number: T05CM02744
Permit Description: REMODEL FIRE DAMAGE:SFR
Total Completed Inspections - 27
Date Description Inspector Results Comments
08/15/2005 ELECTRIC - TEMP POWER FOR TEST ROHAVER Approved IVRS - Inspection :*
08/16/2005 TEP CLEARANCE - AM FGREER Approved ECO CLEARED BY OHAVER
12/08/2005 ROOF NAILING RCAMACHO Approved IVRS - Inspection :*
1) EXCEPT EXISTING FRONT PORCH AND REAR BATHROOM
12/08/2005 FRAMING RCAMACHO Approved IVRS - Inspection :*
12/08/2005 EXT METAL CLIPS/EXT SHEATHING RCAMACHO Approved IVRS - Inspection :*
05/11/2006 ELECTRIC - CONSTRUCTION POWER ROHAVER Approved IVRS - Inspection :
See detailed listing on site.| 999*
1. INSTALL DEADFRONTS BOTH SIDES.
2. INSTALL BREAKER TO FEED GFCI OUTLETS.
3. UNDERSIZED GROUNDING ELECTRODE CONDUCTOR
4. UNDERSIZED GROUNDING ELECTRODE CONDUCTOR TO BE CONTINUOUS FROM GROUND ROD TO GROUND INTO PANEL.
5. CLAMPS LOOSE ON GROUND RODS.
6. GROUND RODS TO BE MINIMUM 6' APART.
7. NO PLANS
8. STOPPED INSPECTION.
05/11/2006 ELECTRIC - RECONNECT ROHAVER Approved IVRS - Inspection :
See detailed listing on site.| 999*
07/18/2006 ELECTRIC - SERVICE UPGRADE ROHAVER Approved IVRS - Inspection :*
10/08/2007 STUCCO MESH CRUIZ Approved IVRS - Inspection :*
11/30/2011 PLUMBING - YARD WTR LINE/TEST LHANLY Approved HOSE BIBBS & NEW PIPE AT SE CORNER OK.

NEED ANTI-SIPHON DEVICES ON HOSE BIBBS BEFORE FINAL
11/30/2011 PLUMBING - INTERMEDIATE LHANLY Approved
10/16/2012 EXCAVATION/LAYOUT REBAR & ZON LHANLY Approved
11/07/2012 MECHANICAL - INTERMEDIATE RMYERS Approved IVRS - Inspection :*
11/07/2012 ELECTRIC - INTERMEDIATE RMYERS Approved IVRS - Inspection :*
11/29/2012 SHEET ROCK NAILING MPUGH Approved IVRS - Inspection :*
06/25/2013 BUILDING - FINAL RCAMACHO Approved 1. SECURE #4 TO BUILDING @ PANEL
2. WHITE HOT LEADS TO BE RED OR BLACK (TAPE OK)
3. PROVIDE PROOF OF 3050 APPROVAL
4. EXTERIOR FIXTURES NOT UNDER ROOF TO BE SHIELDED
5. SEC PANEL LEAD CONDUCTORS NOT TO EXIT TOP WALL
6. STOOP EXIT DOORS
7. PROTECT LINE SET FROM ELEMENTS
8. PAINT ROOF VENTS
9. PROVIDE GAS BOND
10 PANEL "B" NOT ALLOWED IN CLOSET. NOT INSTALLED TO PLAN LOCATION
11. GFCI @ MASTER BATH DOES NOT TEST
9. PROVIDE GAS BOND
06/25/2013 OUTDOOR LIGHTING FINAL RCAMACHO Approved IVRS - Inspection :
See detailed listing on site.| 999*
06/25/2013 MECHANICAL - FINAL RCAMACHO Approved IVRS - Inspection :
See detailed listing on site.| 999*
06/25/2013 PLUMBING - FINAL RCAMACHO Approved IVRS - Inspection :
See detailed listing on site.| 999*
06/25/2013 BUILDING - FINAL RCAMACHO Approved IVRS - Inspection :
See detailed listing on site.| 999*
06/28/2013 PLUMBING - GAS RECONNECT RMYERS Approved
06/28/2013 PLUMBING - GAS PRESSURE TEST RMYERS Approved
06/28/2013 PLUMBING - GAS PRESS TEST FNL RMYERS Approved
08/14/2013 ELECTRIC - FINAL MPUGH Approved IVRS - Inspection :*
01/08/2014 ELECTRIC - OUTDOOR LIGHTING RMYERS Approved
01/08/2014 ELECTRIC - UNDERGROUND RMYERS Approved
01/08/2014 U VALUE FOR WINDOW RMYERS Approved

Documents

File Name Document Type  
None DOCUMENTS VIEW
None CONSTRPLANS VIEW
001_ROOF FRAMING S1.TIF CONSTRPLANS VIEW
001_FLOORPLAN2.TIF CONSTRPLANS VIEW
002_DIMENSION3.TIF CONSTRPLANS VIEW
003_FRFP4.TIF CONSTRPLANS VIEW
004_DETAILS6.TIF CONSTRPLANS VIEW
005_ELECTRICAL SHEET 7.TIF CONSTRPLANS VIEW
006_MECHANICAL SHEET 8.TIF CONSTRPLANS VIEW
007_WASTEPLAN10.TIF CONSTRPLANS VIEW
008_SUPPLY PLAN SHEET 9.TIF CONSTRPLANS VIEW