Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T05CM02674
Permit Details
Apply Date:
06/10/2005
Applicant:
D R HORTON HOMES
Description:
TOWNHOUSE:TD#16-31-30
Contractors:
- D R HORTON HOMES
Permit Reviews
Permit Number - T05CM02674
Permit Status: Expired
Permit Description: TOWNHOUSE:TD#16-31-30
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
06/10/2005 | RESIDENTIAL BLDG-MODEL PLAN/ENGINE/WALK THRU | 08/17/2005 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T05CM02674
Permit Status: Expired
Permit Description: TOWNHOUSE:TD#16-31-30
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
06/10/2005 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T05CM02674
Permite Description: TOWNHOUSE:TD#16-31-30
Total Outstanding Inspections - 3
Last Inspection Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
STUCCO MESH | N/A | Not Inspected | ||
U VALUE FOR WINDOW | N/A | Not Inspected | ||
11/26/2007 | BUILDING - FINAL | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* FIRESTOP @ LAV NO PLASTER RINGS TO BE USED IN FIREWALL |
Completed Inspections
Permit Status: Expired
Permit Number: T05CM02674
Permit Description: TOWNHOUSE:TD#16-31-30
Total Completed Inspections - 22
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/16/2005 | PLUMBING - ROUGH, SOIL | CTREVILL | Approved | IVRS - Inspection :* |
09/23/2005 | BUILDING PRE-SLAB | AMATHIES | Approved | IVRS - Inspection :* |
09/23/2005 | EXCAVATION/LAYOUT REBAR & ZON | AMATHIES | Approved | IVRS - Inspection :* |
09/27/2005 | ELECTRIC - UFER | DSANTACR | Approved | IVRS - Inspection :* |
11/01/2005 | ROOF NAILING | AMATHIES | Approved | IVRS - Inspection :* |
11/01/2005 | EXT METAL CLIPS/EXT SHEATHING | AMATHIES | Approved | IVRS - Inspection :* |
12/01/2005 | FRAMING | AMATHIES | Approved | IVRS - Inspection :* |
12/02/2005 | ELECTRIC - INTERMEDIATE | RSUBA | Approved | IVRS - Inspection :*OK WALLS & CEILINGS EXCEPT ? ROMEX NOT ALLOWED TO BE RUN BELOW SLAB FOR KITCHEN ISLAND-MUST BE U F |
12/02/2005 | PLUMBING - GAS PRESSURE TEST | RRICH | Approved | IVRS - Inspection :* 15 PSI TEST FROM METER TO STOVE, WATER HEATER, FURNACE, DRYER OK. APPROVED |
12/05/2005 | PLUMBING - INTERMEDIATE | RRICH | Approved | IVRS - Inspection :*WASTE & VENT ROOF WATER TEST OK WATER PIPING OK CLOSET FLANGES OK |
12/06/2005 | MECHANICAL - INTERMEDIATE | CWILLIAM | Approved | IVRS - Inspection :* |
12/16/2005 | PLUMBING - SEWER HCS CONNECT | RRICH | Approved | IVRS - Inspection :* |
12/21/2005 | PLUMBING - YARD WTR LINE/TEST | RRICH | Approved | IVRS - Inspection :* 1. WILL NEED TO VIEW LAST 30' WITH CONNECTION TO BUILDING OK |
12/21/2005 | SHEET ROCK NAILING | AMATHIES | Approved | IVRS - Inspection :* |
01/12/2006 | ELECTRIC - TEMPORARY SERVICE | DSANTACR | Approved | IVRS - Inspection :* |
01/12/2006 | ELECTRIC - CABLE DROP | DSANTACR | Approved | IVRS - Inspection :* |
01/13/2006 | TEP CLEARANCE - AM | JKOZUCH | Approved | TEC |
10/19/2007 | PLUMBING - GAS PRESS TEST FNL | RLEDONNE | Approved | IVRS - Inspection :* |
10/19/2007 | ELECTRIC - FINAL | DSANTACR | Approved | IVRS - Inspection :* |
10/24/2007 | ASSURANCE | DROBERTS | Approved | |
10/30/2007 | PLUMBING - FINAL | RLEDONNE | Approved | IVRS - Inspection :* |
11/21/2007 | MECHANICAL - FINAL | MRAMBER | Approved | IVRS - Inspection :* |